Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Transcatheter aortic valve implantation (TAVI) has become an alternative to surgical replacement of the aortic valve elderly patients. However, TAVI patients may suffer from paravalvular leaks (PVL). Detecting and grading is usually done by echocardiography, but is limited by resolution, 2D visualization and operator dependency. 4D flow magnetic resonance imaging (MRI) is a promising alternative, which did not reach clinical application in TAVI patients. The aim of this study was applying 3D printing technologies in order to evaluate flow patterns and hemodynamics of PVLs following TAVI, exploiting 4D flow MRI and standard ultrasound.

Materials And Methods: An MR-compatible, anatomically left ventricle, aortic root, and ascending aorta model was fabricated by combining 3D-printed parts and various soft silicone materials to match physiological characteristics. An Abbott Portico™ valve was used in continuous antegrade flow (12-22 l/min), retrograde flow with varying transvalvular pressures (60-110 mmHg), and physiological pulsatile hemodynamics (aortic pressure: 120/80 mmHg, cardiac output: 5 l/min) Time-resolved MR measurements were performed above and below the TAVI stent and compared with color Doppler ultrasound measurements in exactly the same setup.

Results: The continuous antegrade flow measurements from MRI largely agreed with the flowmeter measurements, and a maximum error of only 7% was observed. In the retrograde configuration, visualization of the paravalvular leaks was possible from the MR measurements, but flow was overestimated by up to 33%. The 4D MRI measurement in the pulsatile setup revealed a single main PVL, which was also confirmed by the color Doppler measurements, and velocities were similar (2.0 m/s vs. 1.7 m/s).

Discussion: 4D MRI techniques were used to qualitatively assess flow in a patient-specific, MR-compatible and flexible model, which only became possible through the use of 3D printing techniques. Flow patterns in the ascending aorta, identification and quantification of PVLs was possible and the location and extent of PVLs were confirmed by ultrasound measurements. The 4D MRI flow technique allowed evaluation of flow patterns in the ascending aorta and the left ventricle below the TAVI stent with good results in identifying PVLs, demonstrating its capabilities over ultrasound by providing the ability to visualize the paravalvular jets in three dimensions at however, additional expenditure of time and money.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894656PMC
http://dx.doi.org/10.3389/fcvm.2023.1083300DOI Listing

Publication Analysis

Top Keywords

paravalvular leaks
12
flow patterns
12
ascending aorta
12
flow
11
aortic root
8
aortic valve
8
tavi patients
8
left ventricle
8
continuous antegrade
8
antegrade flow
8

Similar Publications

A Comparison of Short-Term Clinical Outcomes Between the Navitor and Evolut Transcatheter Aortic Valve Prostheses.

J Clin Med

August 2025

Department of Cardiovascular Surgery, Institute Insure, German Heart Center Munich, School of Medicine & Health, Technical University of Munich, 80636 Munich, Germany.

The novel Navitor intra-annular self-expandable transcatheter aortic valve prosthesis is designed to improve coronary access, reduce paravalvular leaks, and enhance hemodynamic performance. Comparative data with the established Evolut platform (R, Pro, FX) are still lacking. This study aimed to evaluate the short-term clinical outcomes of Navitor (NAV) versus Evolut transcatheter heart valves.

View Article and Find Full Text PDF

Thrombosis Risk in Patients With Mitral Paravalvular Leak: A New Phenomenon in Mechanical Prosthetic Valves.

Can J Cardiol

August 2025

Department of Cardiology, Koşuyolu Heart Training and Research Hospital, Istanbul, Türkiye; Faculty of Health Sciences, Ardahan University, Ardahan, Türkiye.

Background: Mitral regurgitation modifies left atrial (LA) hemodynamics, potentially reducing thrombus formation through the "washout effect." However, the role of paravalvular leaks (PVLs) in thrombus formation remains unclear. In this study we examined the development of thrombosis in patients with mild-moderate and severe mitral PVL.

View Article and Find Full Text PDF

Objectives: Mitral valve replacement (MVR) in patients with severe mitral annular calcification (MAC) remains technically challenging because of the risk of annular disruption and associated complications. We report short-term outcomes of a novel surgical approach that creates an atrial neoannulus for prosthetic valve implantation in high-risk patients with severe mitral stenosis or mixed disease.

Methods: Between September 2021 and January 2025, 27 consecutive patients with severe MAC underwent MVR at a tertiary referral center.

View Article and Find Full Text PDF

Objectives: Mitral regurgitation (MR) represents the most common valvular heart disease (VHD) in the Western world. While transcatheter mitral valve repair (M-TEER) is the leading interventional treatment for surgically high-risk patients, transcatheter mitral valve implantation (TMVI) is reserved for selected patients with unsuitable anatomy for M-TEER. This review aims to summarize our institutional experience with TMVI using the Tendyne™ valve (Abbott Vascular, CA, USA), focusing on interdisciplinary preoperative, intraoperative, and postoperative management strategies.

View Article and Find Full Text PDF

Left ventricular wire pacing technique in transcatheter aortic valve replacement.

J Cardiothorac Surg

August 2025

Department of Cardiology, The Second Hospital of Hebei Medical University, No. 215 of Heping West Road, Xinhua District, Shijiazhuang, 050000, China.

Objective: To assess the impact of using the left ventricular lead pacing technique in transcatheter aortic valve replacement (TAVR) procedure.

Methods: Thirty patients who underwent TAVR using the left ventricular lead pacing technique between January 2022 and July 2022 were selected as the study group. The research monitored intraoperative pacing effectiveness, the successful placement of "valve-in-valve" during the surgical procedure, the frequency of severe complications both during and after the surgery, surgical duration, total radiation dose, and overall hospitalization expenses.

View Article and Find Full Text PDF