Aims: Prolonged right ventricular pacing (RVP) increases the risk of cardiomyopathy, atrial fibrillation, heart failure (HF), and mortality. This registry-based trial compared left bundle branch area pacing (LBBAP) with RVP in patients younger than 65 years.
Methods And Results: Using the ConTempoRary Cardiac Stimulation in Clinical practicE: lEft, BivEntriculAr, Right, and conDuction System Pacing (TREEBEARD) registry (NCT06324682), patients were randomized 1:1 to LBBAP or RVP.
Undersea Hyperb Med
August 2025
Background: Diving is a diffused recreational activity, and the number of divers carrying cardiac implanted devices is similarly growing. Due to the lack of guidelines or technical indications, the suitability of such devices for diving or the fitness to dive for these patients still needs to be determined.
Objective: This work summarizes implantable cardiac devices' suitability for recreational diving, technical vulnerability factors, and recommendations to improve implanted divers' safety.
J Cardiovasc Dev Dis
July 2025
Cardiac magnetic resonance (CMR) imaging provides significant advantages in the non-invasive diagnosis of cardiac diseases. An emerging phenotype is increasingly being described in CMR reports, the LGE "ring-like" pattern, which resembles a circumferential/semi-circumferential LV scar. Different conditions exhibit this fibrosis distribution, the majority of them being genetically determined and mostly involving cardiomyopathy-causative genes (desmosomal but also other non-desmosomal related genes).
View Article and Find Full Text PDFBackground: The implantable cardioverter-defibrillator (ICD) is recognized as the most effective life-saving therapy in patients with Brugada syndrome (BrS). However, transvenous ICD is associated with a notable rate of complications over time. The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as a promising alternative to the transvenous ICD.
View Article and Find Full Text PDFBackgrounds: After a decade since the introduction of leadless pacemaker (L-PM), its use is still limited. The aim of this survey is to evaluate how this technology is perceived by electrophysiologist members of a National scientific society in clinical practice.
Methods: A questionnaire with 22 questions was posted in the reserved area of the society website.
Circ Arrhythm Electrophysiol
March 2025
Background: The safety of subcutaneous implantable cardioverter defibrillator (S-ICD) recipients who lead active lifestyles and engage in recreational sports is unknown. We aimed to evaluate the association between lifestyle and recreational sports and the occurrence of arrhythmia- and device-related complications, appropriate and inappropriate shocks in S-ICD recipients.
Methods: We assessed a cohort of young-adult (15-65 years) S-ICD patients, evaluated their physical activity with IPAQ (International Physical Activity Questionnaire), and assessed the association between lifestyle and recreational sports on S-ICD safety and shocks.
J Clin Med
February 2025
: Right ventricular pacing (RVP), leadless pacing (LL), and conduction system pacing (CSP) are treatment options for atrioventricular block (AVB), each with distinct characteristics. However, the long-term outcomes of these pacing strategies remain insufficiently compared. This study evaluates clinical and echocardiographic outcomes of patients with AVB treated with dual chamber RVP, His bundle pacing (HBP), or LL.
View Article and Find Full Text PDFAims: The subcutaneous implantable cardioverter defibrillator (S-ICD) is an alternative to traditional ICDs. The PRAETORIAN score, based on chest radiographs, has been validated to predict the probability of successful S-ICD defibrillation testing by assessing factors like fat thickness between the coil and sternum and generator placement. This study evaluated the correlation between the PRAETORIAN score and clinical characteristics, as well as implantation variables.
View Article and Find Full Text PDFCardiac implantable electronic devices infections (CIEDI) are associated with poor survival despite the improvement in transvenous lead extraction (TLE). Aetiology and systemic involvement are driving factors of clinical outcomes. The aim of this study was to explore their contribute on overall mortality.
View Article and Find Full Text PDFBackground: The HeartLogic algorithm (Boston Scientific, St Paul, MN) integrates data from implantable cardioverter-defibrillator (ICD) sensors to predict heart failure (HF) decompensation: first (S1) and third (S3) heart sounds, intrathoracic impedance, respiration rate, ratio of respiration rate to tidal volume (RSBI), and night heart rate.
Objective: This study assessed the relative changes in ICD sensors at the onset of HeartLogic alerts, their association with patient characteristics, and outcomes.
Methods: The study included 568 patients with HF carrying ICDs (CRT-D, n = 410) across 26 centers, with a median follow-up of 26 months.
Atrial high-rate episodes (AHREs) and subclinical atrial fibrillation (AF) are frequently registered in asymptomatic patients with cardiac implantable electronic devices (CIEDs) and insertable cardiac monitors (ICMs). While an increased risk of thromboembolic events (e.g.
View Article and Find Full Text PDFBackground: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as an alternative to transvenous systems for prevention of sudden cardiac death. However, concerns have been raised regarding its efficacy and safety in obese individuals.
Objective: The purpose of this study was to perform a meta-analysis to evaluate the efficacy and safety of the S-ICD in patients with obesity by assessing the relationship between body mass index (BMI) and clinical outcomes.
Background: Left ventricular lead positioning represents a key step in CRT optimization. However, evidence for its guidance based on specific topographical factors and related imaging techniques is sparse.
Objective: To analyze reverse remodeling (RR) and clinical events in CRT recipients based on LV cathode (LVC) position relative to latest mechanical activation (LMA) and scar as determined by cardiac magnetic resonance (CMR).
Background: Cardiac resynchronization therapy (CRT) represents an effective heart failure treatment, associated with reduction in mortality and heart failure hospitalizations. This Italian survey aimed to address relevant CRT issues.
Methods: An online survey was administered to AIAC members.
Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve the outcomes in patients with symptomatic, refractory atrial fibrillation (AF). In this setting, AVJA can be performed simultaneously with implantation or in a second procedure a few weeks after implantation. Comparison data on these two alternative strategies are lacking.
View Article and Find Full Text PDFBackground: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE.
Objective: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence.
Background: Conduction system disorders represent a frequent complication in patients undergoing surgical (surgical aortic valve replacement, SAVR) or percutaneous (transcatheter aortic valve implantation, TAVI) aortic valve replacement. The purpose of this survey was to evaluate experienced operators approach in this clinical condition.
Methods: This survey was independently conducted by the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) and it consisted of 24 questions regarding the respondents' profile, the characteristics of participating centres, and conduction disease management in different scenarios.
Background: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking.
View Article and Find Full Text PDFPostpartum electrical storm due to torsade de pointes is a rare but life-threatening condition. The uniqueness of this case lies in the use of cabergoline to suppress postpartum ventricular arrhythmias in absence of heart disease. Timely multidisciplinary management is crucial to achieve final diagnosis, deliver proper treatment and improve prognosis.
View Article and Find Full Text PDF