Aims: Prolonged right ventricular pacing (RVP) increases the risk of cardiomyopathy, atrial fibrillation, heart failure (HF), and mortality. This registry-based trial compared left bundle branch area pacing (LBBAP) with RVP in patients younger than 65 years.
Methods And Results: Using the ConTempoRary Cardiac Stimulation in Clinical practicE: lEft, BivEntriculAr, Right, and conDuction System Pacing (TREEBEARD) registry (NCT06324682), patients were randomized 1:1 to LBBAP or RVP.
Undersea Hyperb Med
August 2025
Background: Diving is a diffused recreational activity, and the number of divers carrying cardiac implanted devices is similarly growing. Due to the lack of guidelines or technical indications, the suitability of such devices for diving or the fitness to dive for these patients still needs to be determined.
Objective: This work summarizes implantable cardiac devices' suitability for recreational diving, technical vulnerability factors, and recommendations to improve implanted divers' safety.
J Cardiovasc Dev Dis
July 2025
Cardiac magnetic resonance (CMR) imaging provides significant advantages in the non-invasive diagnosis of cardiac diseases. An emerging phenotype is increasingly being described in CMR reports, the LGE "ring-like" pattern, which resembles a circumferential/semi-circumferential LV scar. Different conditions exhibit this fibrosis distribution, the majority of them being genetically determined and mostly involving cardiomyopathy-causative genes (desmosomal but also other non-desmosomal related genes).
View Article and Find Full Text PDFBackground & Aims: Hepatocytes are the liver's main functional cells and are key targets for in vivo gene therapy to treat monogenic diseases. Integrating the transgene into the genome is critical for long-term expression from a single early-life dose, which is achievable via integrating vectors or genome editing. To ensure persistence through liver growth and cell turnover, it is also necessary to target the hepatocytes driving these processes.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
August 2025
Introduction: Creation of a pocket and implant of a cardiac implantable electronic device (CIED) elicits a foreign body response in the presence of the normal wound healing process. An absorbable antibacterial envelope (TYRX™, Medtronic Inc.) was developed to stabilize CIEDs and reduce infections.
View Article and Find Full Text PDFLentiviral vector (LV)-mediated ex vivo gene therapy for haematopoietic stem and progenitor cells (HSPCs) has delivered on the promise of a 'one-and-done' treatment for several genetic diseases. However, ex vivo manipulation and patient conditioning before transplantation are major hurdles that could be overcome by an in vivo approach. Here we demonstrate that in vivo gene delivery to HSPCs after systemic LV administration is enabled by the substantial trafficking of these cells from the liver to the bone marrow in newborn mice.
View Article and Find Full Text PDFIn vivo gene therapy to the liver using lentiviral vectors (LV) may represent a one-and-done therapeutic approach for monogenic diseases. Increasing LV gene therapy potency is crucial for reducing the effective doses, thus alleviating dose-dependent toxicities and facilitating manufacturing. LV-mediated liver transduction may be enhanced by positively selecting LV-transduced hepatocytes after treatment (a posteriori) or by augmenting the initial fraction of LV-targeted hepatocytes (a priori).
View Article and Find Full Text PDFHeartRhythm Case Rep
January 2025
Background And Objective: Device-detected subclinical atrial fibrillation (DDAF) and diabetes mellitus (DM) are common in patients with cardiac implantable devices. Our objective was to compare DDAF incidence between diabetic and non-diabetic patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D), using propensity score (PS) matching to adjust for confounders.
Methods: Data from the Home Monitoring Expert Alliance dataset were analyzed for patients with ICD or CRT-D and no prior clinical AF.
J Cardiovasc Electrophysiol
June 2025
Background: Device-detected subclinical atrial fibrillation (DDAF) is a significant risk factor for major cardiovascular events, especially in implantable cardioverter-defibrillator (ICD) recipients. The DX ICD, which utilizes a single ventricular lead with a floating atrial dipole, has demonstrated superior performance in diagnosing DDAF compared to conventional single-lead ICDs. However, comparisons between DX and dual-chamber (DDD) ICDs for atrial monitoring are limited.
View Article and Find Full Text PDFAims: Electrocardiogram (ECG) analysis plays a central role in Anderson-Fabry disease (AFD) diagnosis and management. This study aimed to assess ECG evolution during follow-up in relation to specific treatment and disease progression.
Methods: Retrospective study of a multicentric cohort of AFD patients with ≥2 ECG and echocardiographic data.
Liver fibrosis occurs in several genetic and acquired disease conditions, leading to alterations of the tissue and metabolism, which may adversely affect viral vector-mediated gene therapy. Here, we assessed the impact of liver fibrosis on in vivo gene transfer to hepatocytes mediated by lentiviral vectors or adeno-associated viral vectors. We exploited two chemically induced fibrosis mouse models characterized by tissue damage in different areas of the liver lobule.
View Article and Find Full Text PDFCocaine consumption is a significant global problem, with an estimated 20 million users worldwide. Sudden cardiac death is frequently reported in this population, particularly among individuals <40 years of age. The role of underlying inherited heart disorders in these cases remains largely unexplored.
View Article and Find Full Text PDFLiver regeneration is supported by hepatocytes and, in certain conditions, biliary epithelial cells (BECs). BECs are facultative liver stem cells that form organoids in culture and engraft in damaged livers. However, BEC heterogeneity in the homeostatic liver remains to be fully elucidated.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
March 2025
Background: The safety of subcutaneous implantable cardioverter defibrillator (S-ICD) recipients who lead active lifestyles and engage in recreational sports is unknown. We aimed to evaluate the association between lifestyle and recreational sports and the occurrence of arrhythmia- and device-related complications, appropriate and inappropriate shocks in S-ICD recipients.
Methods: We assessed a cohort of young-adult (15-65 years) S-ICD patients, evaluated their physical activity with IPAQ (International Physical Activity Questionnaire), and assessed the association between lifestyle and recreational sports on S-ICD safety and shocks.
: Right ventricular pacing (RVP), leadless pacing (LL), and conduction system pacing (CSP) are treatment options for atrioventricular block (AVB), each with distinct characteristics. However, the long-term outcomes of these pacing strategies remain insufficiently compared. This study evaluates clinical and echocardiographic outcomes of patients with AVB treated with dual chamber RVP, His bundle pacing (HBP), or LL.
View Article and Find Full Text PDFAims: The subcutaneous implantable cardioverter defibrillator (S-ICD) is an alternative to traditional ICDs. The PRAETORIAN score, based on chest radiographs, has been validated to predict the probability of successful S-ICD defibrillation testing by assessing factors like fat thickness between the coil and sternum and generator placement. This study evaluated the correlation between the PRAETORIAN score and clinical characteristics, as well as implantation variables.
View Article and Find Full Text PDFCardiac implantable electronic devices infections (CIEDI) are associated with poor survival despite the improvement in transvenous lead extraction (TLE). Aetiology and systemic involvement are driving factors of clinical outcomes. The aim of this study was to explore their contribute on overall mortality.
View Article and Find Full Text PDFThe historical restriction of magnetic resonance imaging (MRI) for patients with cardiac implantable electronic devices (CIEDs) has been lifted by certified MRI-conditional systems in recent years. Mixed-brand CIED systems consisting of a generator from one manufacturer and at least one lead from another manufacturer are not certified for MRI. We evaluated the temporal trend in the prevalence of mixed-brand systems in the era of MRI-conditional systems.
View Article and Find Full Text PDFEur J Prev Cardiol
November 2024
Aims: Left ventricular (LV) ring-like scar on cardiac magnetic resonance (CMR) has been linked to malignant arrhythmias in patients with non-ischemic cardiomyopathy. This study aimed to perform a comprehensive evaluation of this phenotype and to identify risk factors for life-threatening arrhythmic events (LAEs), a composite of sudden cardiac death (SCD), aborted SCD, and sustained ventricular tachycardia.