Publications by authors named "Cinzia Valzania"

Chemotherapy-induced cardiomyopathy (CHIC) represents a growing clinical challenge due to the increasing use of cardiotoxic treatments. These therapies can lead to progressive myocardial dysfunction, ultimately resulting in heart failure. Cardiac resynchronization therapy (CRT) has been widely investigated in selected patients with chronic heart failure; however, those with CHIC remain underrepresented in CRT trials.

View Article and Find Full Text PDF

Cancer therapy-induced cardiotoxicity is an emerging clinical and healthcare issue. Myocardial dysfunction and heart failure are mostly responsible for increased cardiovascular mortality in cancer disease survivors. Several imaging surveillance techniques have been proposed for early diagnosis of cancer therapy-induced cardiac dysfunction.

View Article and Find Full Text PDF

Background: Repeated procedures involving the cardiac implantable electronic device (CIED) pocket increase the infection risk, and the extent of pocket adhesions may prolong the procedure time. Few data on pocket histology at the time of CIED replacement are available.

Objective: The purpose of this study was to describe CIED pocket histology in a cohort of patients undergoing CIED replacement or upgrade.

View Article and Find Full Text PDF

Purpose: Relatively few data are available on long-term survival and incidence of ventricular arrhythmias in cardiac resynchronization therapy (CRT) patients. We investigated long-term outcomes of CRT patients with non-ischemic dilated cardiomyopathy stratified as responders or non-responders according to radionuclide angiography.

Methods: Fifty patients with non-ischemic dilated cardiomyopathy undergoing CRT were assessed by equilibrium Tc radionuclide angiography with bicycle exercise at baseline and after 3 months.

View Article and Find Full Text PDF

The current narrative review provides an update of available knowledge on venous access techniques for cardiac implantable electronic device implantation, with a focus on axillary vein puncture. Lower procedure-related and lead-related complications have been reported with extrathoracic vein puncture techniques compared with intrathoracic accesses. In particular, extrathoracic lead access through the axillary vein seems to be associated with lower complication incidence than subclavian vein puncture and higher success rate than cephalic vein cutdown.

View Article and Find Full Text PDF

Nuclear imaging techniques like single-photon emission computed tomography (SPECT) and radionuclide angiography have wide applications in patients receiving a cardiac implantable electrical device (CIED), who cannot usually undergo cardiac magnetic resonance. Our aim was to provide an update of single-photon imaging clinical applications, with a specific focus on CIED recipients. SPECT imaging is commonly used in CIED patients to assess myocardial perfusion, but it can also be used to evaluate myocardial viability, which is an important predictor of LV function improvement by cardiac resynchronization therapy (CRT).

View Article and Find Full Text PDF

To investigate cardiac implantable electrical device (CIED) first implants in patients with hypertrophic cardiomyopathy (HCM) in a Swedish tertiary university hospital. Clinical and technical data on pacemaker, implantable cardioverter defibrillator (ICD), and cardiac resynchronization therapy (CRT) first implants performed in HCM patients at the Karolinska University Hospital from 2005 to 2016 were extracted from the Swedish Pacemaker and ICD Registry. Echocardiographic data were obtained by review of hospital recordings.

View Article and Find Full Text PDF

: Cardiac resynchronization therapy (CRT) is an established treatment in patients with symptomatic drug-refractory heart failure and broad QRS complex on the surface ECG. Despite the presence of either mechanical dyssynchrony or viable myocardium at the site where delivering left ventricular pacing being necessary conditions for a successful CRT, their direct assessment by techniques of cardiovascular imaging, though feasible, is not recommended in clinical practice by the current guidelines. Indeed, even though there is growing body of data providing evidence of the additional value of an image-based approach as compared with routine approach in improving response to CRT, these results should be confirmed in prospective and large multicentre trials before their impact on CRT guidelines is considered.

View Article and Find Full Text PDF

Aims: Common methodologies for analysis of analogous data sets are needed for international comparisons of treatment and outcomes. This study tests using administrative hospital discharge (HD) databases in five European countries to investigate variation/trends in pacemaker (PM) and implantable cardioverter defibrillator (ICD) implant rates in terms of patient characteristics/management, device subtype, and initial implantation vs. replacement, and compares findings with existing literature and European Heart Rhythm Association (EHRA) reports.

View Article and Find Full Text PDF

Background: We compared clinical and technical outcome of CRT recipients treated either with a conventional 3‑leads (3L) CRTD or with the new 2‑leads (DX) CRTD that enables atrial signal detection by a floating dipole built on a pentafilar RV lead.

Methods: Echocardiography and cardiopulmonary exercise tests were repeated either before CRTD implantation and between 6 and 12 months follow up in consecutively implanted patients who had a resting heart rate>40bpm at maximum tolerated beta-blocker dosage. HF status, reverse LV remodeling, exercise tolerance and chronotropic incompetence were assessed at 12 months FU.

View Article and Find Full Text PDF

Aim: We carried out this study to investigate mid-term effects of cardiac resynchronization therapy (CRT) on right ventricular (RV) function and neurohormonal response, expressed by N-terminal pro-brain natriuretic peptide (NT-proBNP), in heart failure patients stratified by baseline RV ejection fraction (RVEF).

Methods And Results: Thirty-six patients with nonischemic dilated cardiomyopathy underwent technetium-99m radionuclide angiography with bicycle exercise immediately after CRT implantation (during spontaneous rhythm and after CRT activation) and 3 months later. Plasma NT proBNP was assessed before implantation and after 3 months.

View Article and Find Full Text PDF

Despite established efficacy for cardiac implantable electrical devices (CIEDs), large differences in CIED implant rates have been documented across and within countries. The aim of this paper is to investigate the influence of socio-economic, epidemiological and supply side factors on CIED implant rates across 57 Regions in 5 EU countries and to assess the feasibility of using administrative data for this purpose. A total of 1 330 098 hospitalizations for CIED procedures extracted from hospital discharge databases in Austria, England, Germany, Italy and Slovenia from 2008 to 2012 was used in the analysis.

View Article and Find Full Text PDF

Changes in left atrial (LA) strain in patients treated with cardiac resynchronization therapy (CRT) remain not entirely explored. We prospectively evaluated long-term changes in LA size and function and their relation with left ventricular (LV) reverse remodeling and noninvasive hemodynamic variables in patients treated with CRT by 2-dimensional speckle tracking echocardiography. Thirty patients (62 ± 11 years, 63% men) underwent 2-dimensional speckle tracking echocardiography before implant and after 12 months.

View Article and Find Full Text PDF

Aims: The longevity of generators is a crucial determinant of the cost-effectiveness of therapy with implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D). We evaluated the trend of device-measured residual battery capacity and longevity projections over 5-year follow-up. We also investigated possible factors associated with battery drain.

View Article and Find Full Text PDF

Background: In recent years, indications for cardiac implantable electrical devices (CIEDs) have broadened; however, budget constraints can significantly impact patient access to these life-saving health technologies.

Objective: To perform a systematic literature review on the implant rates of pacemakers, cardioverter-defibrillators, and cardiac resynchronization therapy devices in Europe over the last decade to provide insight into the possible reasons for differences across regions or countries.

Methods: Four electronic databases were searched to find studies describing CIED implant rates in Europe.

View Article and Find Full Text PDF

Aims: To evaluate the potential impact of the different definitions of non-valvular atrial fibrillation reported in the literature and to analyse the possible implications for eligibility for novel oral anticoagulants (NOACs) in clinical practice.

Methods: We derived the definitions of 'non-valvular atrial fibrillation' from the exclusion criteria of the trials on NOACs, and then assessed the number and percentage of patients fulfilling the various definitions in a cohort of 500 consecutive atrial fibrillation patients, undergoing clinical and echocardiographic evaluation in our cardiology department, as either in-patients or out-patients.

Results: Among the 500 atrial fibrillation patients (mean age 71.

View Article and Find Full Text PDF

Aims: The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival.

Methods And Results: Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website.

View Article and Find Full Text PDF

Atrial fibrillation (AF) may occur in the absence of identifiable causes, co-morbidities or structural cardiac disease (lone AF). Silent AF is common and patients may have a completely asymptomatic arrhythmia or may experience both symptomatic and asymptomatic AF episodes. It has been estimated that among patients with recognized AF, one third has no appreciable symptoms.

View Article and Find Full Text PDF

The implantable cardioverter-defibrillator (ICD) is an example of an effective intervention with high up-front costs and delayed benefits. It has become a proven and well-accepted therapy not only for secondary but also for primary prevention of sudden cardiac death in patients with ischemic and non-ischemic heart disease. In recent years, the international guidelines have extended the indications to the prophylactic ICD, increasing the number of eligible patients and, together, the financial challenges of a widespread implementation.

View Article and Find Full Text PDF

Purpose: Quadripolar left ventricular (LV) leads allow for several pacing configurations in candidates for cardiac resynchronization therapy (CRT). Whether different pacing configurations may affect LV dyssynchrony and systolic function is not completely known. We aimed to evaluate the acute effects of different pacing vectors on LV electromechanical parameters in patients implanted with a quadripolar LV lead.

View Article and Find Full Text PDF

Atrial fibrillation (AF) and heart failure (HF) are two emerging epidemics in the cardiovascular field and are strictly inter-related since may directly predispose to each other. Cardiac resynchronization therapy (CRT) has emerged as an important therapeutic option for selected HF patients with LV dysfunction and ventricular dyssynchrony. However almost all RCTs demonstrated the CRT effectiveness in patients in sinus rhythm (SR), including permanent AF among the exclusion criteria.

View Article and Find Full Text PDF

Relatively few data have been reported on prospective changes in global longitudinal strain (GLS) following cardiac resynchronization therapy (CRT), and none are available on GLS during physical exercise. We investigated the effects of CRT on GLS, assessed by speckle tracking two-dimensional (2D) echocardiography, at rest and during exercise after a mid-term follow-up. Twenty consecutive CRT patients (45% ischaemic) were assessed prospectively by speckle tracking 2D echocardiography before implant (at rest) and at mid-term follow-up (during rest and bicycle exercise).

View Article and Find Full Text PDF