Electrogenerated chemiluminescence (ECL) methods have been widely used in clinical diagnosis. Although ECL peptide-based biosensors continue to grow with good sensitivity and signal flexibility, little emphasis has been placed on the effect of the peptide sequence on ECL sensitivity. We herein studied the nuanced effects of different peptide sequences on the analytical performance of ECL peptide-based biosensors for matrix metalloproteinase 2 (MMP-2) assay, in which [(pbz)Ir(DMSO)Cl] (pbz = 3-(2-pyridyl)benzoic acid) was used as the ECL emitter while a specific peptide was used as the molecular recognition element.
View Article and Find Full Text PDFACS Appl Mater Interfaces
July 2025
Herpes simplex keratitis (HSK) is a chronic, sight-threatening ocular condition caused by herpes simplex virus type 1 (HSV-1). Due to the limited efficacy and significant side effects of current treatments, enhancing the host's immune response to clear the virus has emerged as a promising therapeutic strategy. However, ocular drug delivery is often hindered by physiological barriers, resulting in low bioavailability of topical eye drops.
View Article and Find Full Text PDFPhotodynamic therapy (PDT) has long been receiving increasing attention for the minimally invasive treatment of cancer. The performance of PDT depends on the photophysical and biological properties of photosensitizers (PSs). The always-on fluorescence signal of conventional PSs makes it difficult to real-time monitor phototherapeutic efficacy in the PDT process.
View Article and Find Full Text PDFHydroxyl radical (·OH), taken as the most active and aggressive reactive oxygen species (ROS), plays an important role in cell redox regulation and ferroptosis processes. It is a great challenge to develop methods for highly selective and sensitive detection and imaging of ·OH. A new near-infrared (NIR) fluorescence probe was designed and synthesized by introducing 3-methylpyrazolone as the specific recognition moiety to the hemicyanine backbone of the NIR fluorophore , which formed with the hydrazine group.
View Article and Find Full Text PDFMatrix metalloproteinase 2 (MMP-2) is an important biomarker for some diseases. Herein, one first-case coordination-based site-specific labeling strategy is proposed for electrogenerated chemiluminescence (ECL) biosensing of MMP-2 by employing an iridium(III) solvent complex as a signal reagent and a histidine (His)-containing peptide as a molecular recognition substrate. One ECL probe was prepared via coordination labeling of the His-containing peptide with one iridium(III) solvent complex ([(3-(2-pyridyl)benzoic acid)Ir(DMSO)Cl], Ir1-DMSO).
View Article and Find Full Text PDFAdv Mater
January 2025
Current battery production relies on the use of large amounts of N-methyl-2-pyrrolidnone (NMP) solvent during electrode preparation, which raises serious concerns in material cost, energy consumption, and toxicity, thus demanding the innovation of dry electrodes with excellent performance. However, state-of-the-art dry electrodes show inferior energy densities, particularly under high-areal-capacity and fast charge/discharge conditions required for practical applications. Here dry production of high-energy-density Li- and Mn-rich (LMR) cathodes is shown based on a thermal-assistant approach.
View Article and Find Full Text PDFObtaining stable electrochemiluminescence (ECL) emissions from a hydrophobic luminophore in aqueous solutions and designing a method without the use of an exogenous coreactant are promising for ECL biosensing. Here, a highly sensitive signal-on ECL immunoassay for the SARS-CoV-2 N protein was developed using micelles as an ECL tag. The micelles were prepared by coencapsulating the luminophore hydrophobic CdSe/ZnS quantum dots and coreactant dibenzoyl peroxide within the hydrophobic core of micelles.
View Article and Find Full Text PDFCont Lens Anterior Eye
October 2024
Purpose: Vitamin D (VD) is a vitamin with anti-inflammatory and immunomodulatory effects. Several studies have shown that VD deficiency is associated with the incidence and severity of dry eye disease (DED) in humans. This meta-analysis compared signs and symptoms in patients with DED before and after VD supplementation.
View Article and Find Full Text PDFAnal Bioanal Chem
September 2024
3-Methylhistidine (3-MeHis) is increasingly used as an indicator of muscle protein breakdown. The development of a sensitive, simple, and non-invasive method for 3-MeHis assay is important in clinical practice. Herein, a sensitive, simple, and non-invasive electrogenerated chemiluminescence (ECL) method was proposed for the quantitation of 3-MeHis in urine by using an iridium(III) solvent complex ([Ir(dfppy)(DMSO)Cl], dfppy = 2-(2,4-difluorophenyl)pyridine, Ir-DMSO) as a signal reagent.
View Article and Find Full Text PDFExosomes, as an emerging biomarker, have exhibited remarkable promise in early cancer diagnosis. Here, a highly sensitive, selective, and automatic electrochemiluminescence (ECL) method for the detection of cancerous exosomes was developed. Specific aptamer-(EK) peptide-tagged magnetic beads (MBs-(EK)-aptamer) were designed as a magnetic capture probe in which the (EK) peptide was used to reduce the steric binding hindrance of cancerous exosomes with a specific aptamer.
View Article and Find Full Text PDFA highly sensitive and selective electrogenerated chemiluminescence (ECL) biosensor was developed for the determination of matrix metalloproteinase 3 (MMP-3) in serum via the target-induced cleavage of an oligopeptide. One ECL probe (named as Ir-peptide) was synthesized by covalently linking a new cyclometalated iridium(III) complex ([(3-pba)Ir(bpy-COOH)](PF)) (3-pba = 3-(2-pyridyl) benzaldehyde, bpy-COOH = 4'-methyl-2,2'-bipyridine-4-carboxylic acid) with an oligopeptide (CGVPLSLTMGKGGK). An ECL biosensor was fabricated by firstly casting Nafion and gold nanoparticles (AuNPs) on a glassy carbon electrode and then self-assembling both of the ECL probes, 6-mercapto-1-hexanol and zwitterionic peptide, on the electrode surface, from which the AuNPs could be used to amplify the ECL signal and Ir-peptide could serve as an ECL probe to detect the MMP-3.
View Article and Find Full Text PDFCysteine (Cys), as one of the biological thiols, is related to many physiological and pathological processes in humans and plants. Therefore, it is necessary to develop a sensitive and selective method for the detection and imaging of Cys in biological organisms. In this work, a novel near-infrared (NIR) fluorescent probe, , was designed by connecting furancarbonyl, as a new recognition moiety, with via the decomposition of IR-806.
View Article and Find Full Text PDFAn enzyme immunoassay was developed based on the coulometric measurement of immunoglobulin M (IgM) against Hantaan viruses (HTNV) by using virus-like particles (VLPs) as recognition molecules. The surface functionalization of screen-printed carbon electrodes (SPCEs) was achieved through paste-exfoliated graphene that was modified with a COOH group and a thionine mediator through supramolecular-covalent scaffolds, on SPCEs by using the binder contained in the ink. After the covalent immobilization of the antibody, the sensor was used for the sandwich enzyme immunoassay of IgM against HTNV.
View Article and Find Full Text PDFChem Commun (Camb)
February 2024
A new fluorescence probe OHPD that could specifically identify acetylcholinesterase/butyrylcholinesterase has been developed and successfully applied to imaging . Probe OHPD shows significant color change, high selectivity, high sensitivity, and low detection limit for the detection of cholinesterase. Moreover, the real-time imaging indicated that endogenous cholinesterase was mainly present in the yolk sac of zebrafish.
View Article and Find Full Text PDFFront Bioeng Biotechnol
December 2023
Numerous microorganisms, including bacteria and fungus, have been identified as capable of degrading rubber. Rubber biodegradation is still understudied due to its high stability and the lack of well-defined pathways and efficient enzymes involved in microorganism metabolism. However, rubber products manufacture and usage cause substantial environmental issues, and present physical-chemical methods involve dangerous chemical solvents, massive energy, and trash with health hazards.
View Article and Find Full Text PDFHistidine (His) and its metabolite analysis is significant due to their vital roles in the diagnosis of diseases. In practical applications, simple and effective detection and discrimination of these metabolic species are still a great challenge due to their highly similar structures. Herein, photoluminescence (PL)-electrochemiluminescence (ECL) dual-mode sensor arrays consisting of a series of sensing elements were proposed for simultaneous quantitation and accurate discrimination of His and its four key metabolites (including histamine, imidazole-4-acetic acid, -acetylhistamine, and imidazole propionate).
View Article and Find Full Text PDFA novel point-of-care testing (POCT) method for the determination of proteases was developed for the first time using a designed disposable capillary-fill device based on the cleavage of electrogenerated chemiluminescence (ECL)-label-tagged peptide probes and enabling elimination of the light-shielding from the magnetic beads (MBs). As a proof-of-principle, prostate-specific antigen (PSA) was taken as a model analyte, and streptavidin-coated magnetic beads bound with ruthenium-complex-tagged specific peptide (biotin-HSSKLQK) were utilized as MB ECL probes. The capillary-fill device was designed to be divided into a reaction zone and detection zone.
View Article and Find Full Text PDFAn electrochemiluminescence (ECL) bioassay with high sensitivity and anti-fouling ability was developed for determination of matrix metalloproteinase 9 (MMP-9) secreted from living cells under external stimulation. A peptide with sequence of CLGRMGLPGK and a new cyclometalated iridium(III) complex bearing carboxyl group, (pq)Ir(dcbpy) (pq = 2-phenylquinoline, dcbpy = 2,2'-bipyridyl-4,4'-dicarboxyli acid, abbreviated as Ir) were employed as molecular recognition substrate and ECL emitter, respectively. The peptide was labelled with the Ir to form Ir-peptide as ECL probe.
View Article and Find Full Text PDFElectrogenerated chemiluminescence (ECL) imaging is gaining increasing attention in various fields because of its high sensitivity, low background, and good temporal and spatial resolution. However, ECL imaging of microsized objects at the opaque electrode via top-view configuration is challenged with the reactants' diffusion and light propagation. Here, we imaged and numerically simulated ruthenium derivative coating polystyrene microbeads (Ru1-PS@MB) at the glassy carbon electrode (GCE) via top-view configuration by ECL imaging.
View Article and Find Full Text PDFWe propose a novel washing-free electrochemiluminescence (ECL) biosensor for the simultaneous detection of two types of N6 methyladenosines-RNAs (mA-RNAs), which are potential cancer biomarkers, on the basis of binding-induced DNA strand displacement (BINSD). The biosensor integrated a tri-double resolution strategy that combined spatial and potential resolution, hybridization and antibody recognition, and ECL luminescence and quenching. The biosensor was fabricated by separately immobilizing two ECL reagents (gold nanoparticles/g-CN nanosheets and ruthenium bipyridine derivative/gold nanoparticles/Nafion) and the capture DNA probe on the two sections of glassy carbon electrode.
View Article and Find Full Text PDFA sensitive and noninvasive cyclic peptide-based electrogenerated chemiluminescence biosensing method for the determination of sweat glucose was developed. Glucose can be quantified in sweat samples with a recovery of 93%-113% one-step recognition, which is promising for the determination of sweat glucose.
View Article and Find Full Text PDFAntonie Van Leeuwenhoek
August 2023
A polyphasic taxonomic study was conducted on two Gram-negative, non-sporulating, non-motile bacterial strains, S2-20-2 and S2-21-1, isolated from a contaminated freshwater sediment in China. Comparative 16S rRNA gene sequence studies revealed a clear affiliation of two strains with Bacteroidetes, which showed the highest pairwise sequence similarities with Hymenobacter duratus BT646 (99.3%), Hymenobacter psychrotolerans Tibet-IIU11 (99.
View Article and Find Full Text PDFThe understanding of the dissolution processes of solids is important for the design and synthesis of solids in a controlled and precise manner and for predicting their fate in the aquatic environment. We report herein single-particle-based confocal laser scanning microscopy (CLSM) for tracking the dissolution surface kinetics of a single fluorescent cyclodextrin metal-organic framework (CD-MOF). As a proof of concept, CD-MOF containing fluorescein, named as CD-MOF⊃FL, was synthesized by encapsulating fluorescein into the interior of CD-MOF via a vapor diffusion method and used as a single-particle dissolution model because of its high FL efficiency and unique structure.
View Article and Find Full Text PDF