Magnetically actuated multimaterial fiberbot for precise minimally invasive knee laser surgery.

Sci Adv

Research Center for Intelligent Fiber Devices and Equipment, Department of Geriatrics, Department of Orthopedics, and Key Laboratory of Vascular Aging, Ministry of Education, Tongji Hospital of Tongji Medical College, State Key Laboratory of New Textile Materials and Advanced Processing, Wuhan Natio

Published: August 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Conventional methods, such as open and arthroscopy-assisted surgery, still encounter challenges in terms of tool flexibility when addressing knee diseases in patients. Robotics has enhanced the precision and efficiency of numerous surgical procedures. However, there is still a lack of minimally invasive surgical tools capable of flexibly resecting knee lesions. Here, we present a flexible fiberbot that integrates steerable midinfrared laser ablation and active navigation functions. The fiberbot features an internal multicore structure for midinfrared laser delivery and an external magnetic elastomer, allowing precise control under an applied magnetic field. The fiberbot was demonstrated to perform precise navigation and steering in a constrained spherical model and an isolated pig knee joint. Moreover, the fiberbot was further demonstrated in steerable laser ablation for leg bones of rats in vivo. Given its compact design, safer actuation, and quicker manipulation, our fiberbot is expected to pave a promising avenue for future knee surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12383248PMC
http://dx.doi.org/10.1126/sciadv.adt1809DOI Listing

Publication Analysis

Top Keywords

minimally invasive
8
midinfrared laser
8
laser ablation
8
fiberbot demonstrated
8
fiberbot
6
knee
5
magnetically actuated
4
actuated multimaterial
4
multimaterial fiberbot
4
fiberbot precise
4

Similar Publications

Minimally invasive and standardized thoracoscopic surgery for stage III empyema using a variable-view rigid endoscope.

Gen Thorac Cardiovasc Surg

September 2025

Department of General Thoracic Surgery, Seirei Hamamatsu General Hospital, 2-12-12, Hamamatsu, Shizuoka, 430-8558, Japan.

Thoracoscopic surgery for stage III acute empyema is often limited by poor visualization and anatomical complexity. We developed a standardized, minimally invasive approach using a variable-view rigid endoscope and fixed port placement, regardless of disease extent or patient physique. The variable-view endoscope enabled a wide, adjustable field of view without moving the camera shaft, allowing safe access even in the confined thoracic space.

View Article and Find Full Text PDF

Non-invasive prediction of invasive lung adenocarcinoma and high-risk histopathological characteristics in resectable early-stage adenocarcinoma by [18F]FDG PET/CT radiomics-based machine learning models: a prospective cohort Study.

Int J Surg

September 2025

Department of Respiratory and Critical Care Medicine, Hubei Province Clinical Research Center for Major Respiratory Diseases, Key Laboratory of Pulmonary Diseases of National Health Commission, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China

Background: Precise preoperative discrimination of invasive lung adenocarcinoma (IA) from preinvasive lesions (adenocarcinoma in situ [AIS]/minimally invasive adenocarcinoma [MIA]) and prediction of high-risk histopathological features are critical for optimizing resection strategies in early-stage lung adenocarcinoma (LUAD).

Methods: In this multicenter study, 813 LUAD patients (tumors ≤3 cm) formed the training cohort. A total of 1,709 radiomic features were extracted from the PET/CT images.

View Article and Find Full Text PDF

Background: Phrenic nerve injury during mediastinal tumor resection can lead to significant postoperative diaphragmatic dysfunction. Current intraoperative protection techniques are imprecise and lack real-time feedback. We aimed to develop and validate a quantifiable, multimodal neuroprotective strategy.

View Article and Find Full Text PDF

Diabetes mellitus (DM) is a chronic metabolic disorder characterized by persistent hyperglycemia with multiple clinical manifestations and complications, such as cardiovascular disease, kidney dysfunction, retinal impairment, and peripheral neuropathy. Continuous and minimally invasive glucose monitoring is essential for effective DM management. Microneedles (MNs)-based sensing platforms offer a promising solution; however, conventional polymeric MNs suffer from limited electrochemical sensitivity due to their insufficient electroactive surface area and inefficient loading of catalytic and enzymatic components.

View Article and Find Full Text PDF