Article Abstract

This study presents the in vitro and preliminary ex vivo development of a novel microneedle-based pH sensor for continuous intrapartum fetal monitoring. The objective was to evaluate the feasibility of using microneedle sensors to monitor fetal pH during labour and to develop a proof-of-principle microneedle pH sensor that meets clinical requirements such as high sensitivity to small pH changes (0.05 units) within a relevant range (6.50-7.45), minimal tissue disruption, and a compact design suitable for transcervical placement on the fetal scalp (<40 mm diameter). Platinum microneedles were passivated with ArCare medical adhesive and coated with iridium oxide via electrodeposition. Sensitivity was tested in phosphate buffered saline (PBS) and artificial interstitial fluid (ISF), using both external Ag/AgCl and internal platinum pseudo-reference electrodes. In PBS, the sensor exhibited linear responses in increments of 0.05 pH units over the clinically relevant range (6.5-7.45), with slopes of -60.49 mV/pH (R = 0.946, accuracy = 97.65%) and -63.2 mV/pH (R = 0.910, accuracy = 93.70%) in the external and internal configurations, respectively. In ISF, a slope of -25.5 mV/pH (R = 0.979) was obtained. Ex vivo testing on human skin confirmed successful microneedle penetration without visible iridium oxide transfer or tissue damage, as indicated by methylene blue staining. These findings support the potential for continuous minimally invasive fetal pH monitoring during labour, representing a significant step toward more objective and specific intrapartum assessment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12384993PMC
http://dx.doi.org/10.3390/bios15080517DOI Listing

Publication Analysis

Top Keywords

microneedle sensor
8
intrapartum fetal
8
fetal monitoring
8
development characterisation
4
characterisation microneedle
4
sensor intrapartum
4
fetal
4
monitoring study
4
study presents
4
presents vitro
4

Similar Publications

Recent advances in three-dimensional (3D) biological brain models in vitro and ex vivo are creating new opportunities to understand the complexity of neural networks but pose the technological challenge of obtaining high-throughput recordings of electrical activity from multiple sites in 3D at high spatiotemporal resolution. This cannot be achieved using planar multi-electrode arrays (MEAs), which contact just one side of the neural structure. Moreover, the specimen adhesion to planar MEAs limits fluid perfusion along with tissue viability and drug application.

View Article and Find Full Text PDF

Electroencephalography-based brain-computer interfaces have revolutionized the integration of neural signals with technological systems, offering transformative solutions across neuroscience, biomedical engineering, and clinical practice. This review systematically analyzes advancements in electroencephalography-based brain-computer interface architectures, emphasizing four pillars, namely signal acquisition, paradigm design, decoding algorithms, and diverse applications. The aim is to bridge the gap between technology and application and guide future research.

View Article and Find Full Text PDF

A flexible microneedle sensor for long-term, enzyme-free glucose monitoring with high sensitivity and stability.

Anal Chim Acta

October 2025

Shanghai Frontier Science Research Center for Advanced Textiles, College of Textiles, Donghua University, Shanghai, 201620, China; Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China. Electronic address:

Background: Blood glucose monitoring is of paramount importance for patients with diabetes. However, conventional glucose meters exhibit limited accuracy and present challenges for prolonged use, primarily due to the high consumption of glucose oxidase (GOD) and their sensitivity to temperature and environmental factors. phenylboronic acid (PBA), benefiting from its reversible reaction with glucose and superior stability, holds potential as a promising medium for long-term glucose monitoring.

View Article and Find Full Text PDF

Diabetic foot ulcers (DFUs) is a severe complication of diabetes, progressing insidiously at early stages but eventually leading to amputation. Therefore, to effectively bring DFUs under control, early diagnosis is crucial. Recent researches have shown that DFUs progression correlates with tissue oxygenation.

View Article and Find Full Text PDF

Cancer remains a critical global health concern, affecting individuals across all age groups and claiming millions of lives annually. Early detection is essential, as it significantly improves prognosis and enhances survival rates. However, conventional diagnostic techniques, despite their accuracy, are often expensive, time-consuming, and inaccessible in remote or resource-limited areas.

View Article and Find Full Text PDF