Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12352966PMC
http://dx.doi.org/10.1055/a-2638-5775DOI Listing

Publication Analysis

Top Keywords

endoscopic titanium
4
titanium clip
4
clip nylon
4
nylon loop
4
loop treating
4
treating esophageal
4
esophageal gastric
4
gastric variceal
4
variceal bleeding
4
bleeding endoscopic
4

Similar Publications

A novel shape-memory Bi-hook device for nasolacrimal duct stent implantation in canalicular laceration repair.

BMC Ophthalmol

September 2025

Department of Ophthalmology, Tongji Hospital, School of Medicine, Tongji University, No.389 Xincun Road, Putuo District, Shanghai, 200065, China.

Purpose: To evaluate the clinical efficacy and safety of a novel shape-memory Bi-hook device in facilitating antegrade stent implantation for canalicular laceration repair.

Methods: In this retrospective comparative study, 76 patients (76 eyes) with canalicular laceration were enrolled: 39 patients (39 eyes) underwent Bi-hook-assisted stent implantation (Bi-hook group) and 37 patients received conventional Ritleng stent intubation (control group). The Bi-hook device was fabricated using a thermally shaped 0.

View Article and Find Full Text PDF

Gastric perforation (GP) is characterized by full-thickness injury of the stomach wall, a severe and potentially life-threatening gastrointestinal disease. However, current treatment, including surgical sutures and endoscopic closure, faces limitations, achieving complete sealing of the perforation and favorable healing remains a great challenge and an acute clinical demand. Here, we report a hydrogel dry powder (PPCL@Mg) for the minimally invasive treatment of GP, which can be delivered to target perforation wounds by spraying via an endoscope, and rapidly absorbing interfacial water and spontaneously forming a hydrogel.

View Article and Find Full Text PDF

Background: This study aimed to compare a 3-dimensional (3D)-printed titanium cage with a polyetheretherketone (PEEK) cage in biportal endoscopic transforaminal lumbar interbody fusion (BETLIF) using a double cage construct, evaluate differences in fusion stability and subsidence between the 2 cage types, and analyze factors influencing subsidence.

Methods: We retrospectively examined 89 patients who underwent BETLIF using a double cage (3D-printed titanium, 48 levels; PEEK, 46 levels). Fusion status and subsidence were assessed using dynamic plain lateral lumbar spine radiographs and computed tomography images at 6 months and 1 year postoperatively.

View Article and Find Full Text PDF

Endoscopic Reverse Stapedotomy for Otosclerosis: A Technical Video Report.

Cureus

August 2025

ENT Department, Hôpital Militaire Oued Eddahab, Agadir, MAR.

Endoscopic stapedotomy offers a panoramic transcanal view of middle-ear structures while minimizing canal trauma. Reverse stapedotomy, in which the footplate fenestration precedes the removal of the stapes superstructure, may improve footplate stability and procedural safety. The use of CT-based three-dimensional (3D) virtual endoscopy for surgical planning in otosclerosis remains uncommon.