98%
921
2 minutes
20
Purpose: To introduce Double Inversion Recovery (DIR) preparations for myocardial Arterial Spin Labeling (myoASL) for mitigation of heart rate (HR) variability induced physiological noise (PN).
Methods: DIR-labeling was implemented for double ECG-gated myoASL-sequences and compared with conventional Flow-sensitive Alternating Inversion Recovery (FAIR) labeling using single inversions. In DIR-preparations, the FAIR-inversion pulses were immediately followed by an identical reinversion pulse, applied either slice-selectively or nonselectively. Bloch-equation-based simulation and phantom experiments were performed to evaluate the PN and SNR across a range of HR variabilities. Data from six healthy subjects were acquired to evaluate myocardial blood flow (MBF), PN, and SNR in vivo.
Results: Simulation experiments showed that the average MBF values remained nearly constant across the range of HR variabilities and were comparable across all three sequences. However, DIR-labeling allowed for greater recovery of the myocardial background signal, which mitigates the sensitivity to HR-dependent changes in the inversion time. Consequently, PN in the presence of HR variability was substantially reduced with DIR-labeling. For HR variabilities corresponding to the mean value observed in vivo, this resulted in a simulated SNR gain of 1.79 0.90 for selective and 1.55 0.77 for nonselective DIR-labeling. In vivo, DIR-labeling showed reduced PN, with 53% ( )/44% ( ) less PN compared with conventional FAIR-myoASL, leading to an average SNR gain of 1.47 0.63 ( )/1.32 0.57 ( ) with selective/nonselective reinversions.
Conclusion: The proposed DIR-preparations reduce sensitivity to HR variations and alleviate PN in double ECG-gated myoASL, improving the precision of myoASL-based perfusion quantification.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mrm.70018 | DOI Listing |
Magn Reson Med
September 2025
Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Purpose: Gadoxetic acid-enhanced hepatobiliary phase T-weighted (Tw) MRI is effective for the detection of focal liver lesions but lacks sufficient T contrast to distinguish benign from malignant lesions. Although the addition of T, diffusion, and dynamic contrast-enhanced Tw imaging improves lesion characterization, these methods often do not provide adequate spatial resolution to identify subcentimeter lesions. This work proposes a high-resolution, volumetric, free-breathing liver MRI method that produces colocalized fat-suppressed, variable Tw images from a single acquisition, thereby improving both lesion detection and characterization.
View Article and Find Full Text PDFComparative clinical efficacy of nickel-titanium shape memory staples versus miniplate for Bartoníček-Rammelt type III and IV posterior malleolar fractures. A retrospective analysis of 47 consecutive patients treated between January 2022 and June 2024 documented operative time, intraoperative blood loss, fluoroscopy times, healing time, complications, postoperative fracture gap distance (mm), and articular surface step-off (mm) at the ankle joint. Ankle function was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, the Manchester-Oxford Foot Questionnaire (MOXFQ), and range of motion measurements at 3, 6, 12, and 14 months.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
September 2025
Positron Emission Tomography (PET) is a critical imaging modality in nuclear medicine but requires radioactive tracer administration, which increases radiation exposure risks. While recent studies have investigated MR-guided low-dose PET denoising, they neglect two critical factors: the synergistic roles of multicontrast MR images and disease-specific denoising requirements. In this work, we propose a diffusion model that integrates T1-weighted, T2 fluid attenuated inversion recovery (T2 FLAIR), and hippocampal-optimized (T2 HIPPO) MR sequences to achieve ultra-low-dose PET denoising tailored for temporal lobe epilepsy (TLE).
View Article and Find Full Text PDFJ Feline Med Surg
September 2025
Department for Small Animals, Veterinary Faculty, Leipzig University, Leipzig, Germany.
ObjectivesThe objective of this study was to evaluate the occurrence of voltage-gated potassium channel (VGKC) antibodies and the pattern of MRI changes in cats with complex partial seizures with orofacial involvement (CPSOFI), as well as to investigate whether there are factors influencing survival that could be used as prognostic markers in those cats.MethodsCats with CPSOFI were identified retrospectively. The following data were retrieved from the hospital database: signalment, age at first seizure and presentation, the presence of antibodies against VGKC (leucine-rich glioma inactivating factor 1 (LGI1), contactin-associated protein 2 (CASPR2)) and cerebrospinal fluid (CSF) analysis findings.
View Article and Find Full Text PDFDirect myelin imaging with inversion-recovery ultrashort-echo-time (IR-UTE) is highly motion-sensitive, yet extra hardware or longer scans are impractical. We evaluated whether a superior-inferior (SI) self-navigator with bit-reversed spoke-angles mitigates motion artifacts without extending acquisition. Dual-echo IR-UTE was implemented at 3T.
View Article and Find Full Text PDF