Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Polymer-based bioresorbable vascular scaffolds (BVS) have garnered significant attention in biomedical applications. Among various BVS, polycaprolactone (PCL)-based scaffolds exhibit excellent biocompatibility, flexibility, chemical stability, and controlled degradation. However, their low radial strength limits practical applicability. Moreover, most reported BVS require periodic postimplantation monitoring to enable early detection of in-stent restenosis and thrombosis. To overcome these limitations, we fabricate a carbon nanotube (CNT)-reinforced PCL BVS using a 3D printing process, enabling patient-specific customization while significantly improving mechanical strength and durability. The proposed PCL/CNT-based stent not only serves as a structural scaffold but also facilitate real-time vascular pressure monitoring by integrating a wireless LC capacitive pressure sensor. The LC pressure sensor is microfabricated using microelectromechanical systems (MEMS) technology and exhibits highly stable resonance characteristics. A key innovation is the integration of a supporting micropillar within the capacitor cavity, which minimizes structural deformation and ensures a stable capacitance response. Mechanical testing demonstrates that PCL/CNT stents achieve significantly higher radial force (0.1 N/mm) compared to pristine PCL (0.013 N/mm). The wireless sensor exhibits high sensitivity (49 kHz/mmHg) with minimal capacitance variation (±5%). studies in a phantom experiment confirm stable resonance frequency fluctuations that accurately correlate with hemodynamic changes. This smart stent integrates biodegradable nanocomposites, 3D printing, and wireless sensing, providing a noninvasive platform for restenosis and thrombosis monitoring. It marks a significant advancement in cardiovascular implants, paving the way for personalized and proactive patient care.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.5c00857DOI Listing

Publication Analysis

Top Keywords

pressure sensor
12
bioresorbable vascular
8
restenosis thrombosis
8
stable resonance
8
3d-printed cnt-reinforced
4
cnt-reinforced bioresorbable
4
vascular scaffold
4
scaffold enhanced
4
enhanced mechanical
4
mechanical stability
4

Similar Publications

All-In-One Iontronic Sensing Aligner for High-Precision 3D Orthodontic Force Monitoring.

Adv Sci (Weinh)

September 2025

Department of Orthodontics, National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, NHC Key Laboratory of Digital Stomatology, NMPA Key

Clear aligners offer aesthetic and comfort advantages in orthodontics, yet their ability to deliver effective forces relies heavily on empirical judgment or large-scale optical scanning, lacking real-time quantitative evaluation. Integrating pressure sensors into aligners is a promising solution, but challenges in miniaturization, multi-dimensional sensing, measurement accuracy, and biocompatibility hinder clinical application. Here, an all-in-one Orthodontic Force Acquisition System (OFAS) is presented that enables real-time, 3D force monitoring using a cross-shaped iontronic sensing array and an origami-inspired, wireless battery-free readout circuit miniaturized for single-tooth placement.

View Article and Find Full Text PDF

Co-Immobilization of Trypsin and Lysine -α- Oxidase For the Quantification of Lysine in Casein Hydrolysate. Evaluation with a Biosensor.

Cell Physiol Biochem

August 2025

Departamento de Procesos Químicos, Alimentos y Biotecnología. Facultad de Ingeniería y Ciencias Aplicadas. Universidad Técnica de Manabí, Portoviejo, Ecuador.

Background/aims: The quantification of amino acids in the dairy industry is necessary for quality control and for the formulation of functional foods. Thus, the development of enzymatic biosensors requires a detailed study of enzyme kinetics. Parameters such as KM and Vmax are necessary to optimize the sensitivity and specificity of the biosensor.

View Article and Find Full Text PDF

The carotid body mediates peak oxygen uptake during maximal physical exertion in rats.

J Physiol

September 2025

Instituto de Ciencias Biomédicas, Facultad de Ciencias de la Salud, Universidad Autónoma de Chile, Santiago, Chile.

Cardiorespiratory responses to physical exercise are expected to meet the organism's metabolic demands. As carotid body (CB) glomus cells have been proposed as metabolic sensors, we sought to determine their contribution to peak oxygen uptake ( ) during exercise in rats. Adult male Wistar Kyoto rats underwent bilateral co-injection of two adeno-associated viruses (AAVs) at the CB bifurcation (AVV-TH-Cre-SV40 and AVV-hSyn-DREADD(Gi)-mCherry).

View Article and Find Full Text PDF

Understanding foot kinetics is fundamental to analyzing human locomotion, offering critical insights into mechanical loads exerted on the feet. While vertical ground reaction force (vGRF) is widely used in biomechanics research, comprehensive 3D kinetic measurements, including ground reaction force (GRF), ground reaction moment (GRM), and center of pressure (CoP) along the anterior-posterior and medial-lateral axes, provide deeper insights for various applications. Smart insoles, though portable, cost-effective, and user-friendly, primarily capture vGRF and often generate lower-quality data than force plates and instrumented treadmills.

View Article and Find Full Text PDF

Digital light processing (DLP) presents a promising approach for fabricating intricately designed piezoelectric components, which are essential for developing high-sensitivity piezoelectric sensor systems. However, the inherent layer-by-layer stacking nature of DLP induces interlayer cracking in printed ceramics, which severely deteriorates their performance. This work introduces an innovative interfacial engineering strategy to print superlattice components with exceptional piezoelectric performance.

View Article and Find Full Text PDF