98%
921
2 minutes
20
Background/aims: To establish sex-specific and grade-specific reference values of cycloplegic spherical equivalent (SE) for predicting myopia onset and progression in Chinese children and adolescents.
Methods: Between 2020 and 2024, vision screening was conducted among 67 260 Chinese students spanning kindergarten to high school. Myopia was defined as a cycloplegic SE of ≤-0.50 diopters (D) and high myopia as ≤-6.00D. The lambda-mu-sigma method was used to estimate centiles of cycloplegic SE for -0.50D and -6.00D at each grade. Based on this, reference values for predicting future myopia and its progression to high myopia were determined for all grades.
Results: Among boys in grade 12 (the third year of high school), the estimated prevalence of myopia and high myopia was 82.4% and 11.6%, respectively. For boys in grades 0-11, the cycloplegic SE values at the 82.4th and 11.6th percentiles served as reference values to predict myopia and high myopia, respectively, in grade 12. For example, among senior kindergarten boys (grade 0), those with cycloplegic SE >1.54D (82.4th percentile) were predicted to remain non-myopic before grade 12, whereas those with SE >0.19D (11.6th percentile) were not expected to develop high myopia before grade 12.
Conclusions: Reference values for predicting myopia and high myopia among Chinese students were established, but these values may not be applicable to populations beyond China. Nevertheless, the proposed methods could be applied to settings where student myopia prevalence patterns remain relatively stable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/bjo-2024-326815 | DOI Listing |
Clin Exp Optom
September 2025
School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
Clinical Relevance: Good vision is critical for childhood development and education. Pre-school vision screening is important for early detection and treatment of visual problems, and prevention of life-long vision loss.
Background: The aim of this study was to determine the prevalence of vision impairment (VI) and refractive error (RE) in rural Nepalese children under five years of age.
J Refract Surg
September 2025
Department of Refractive Surgery, Shanghai Aier Eye Hospital, Shanghai.
Purpose: To analyze the effects of ablation interruption on ablation depths and clinical refractive outcomes to characterize the impact of ambient temperature changes and ablation interruption on ocular surface temperature (OST) during excimer laser ablation.
Methods: This prospective study was conducted on laser ablations in polymethylmethacrylate (PMMA) plates and porcine corneas to simulate laser in situ keratomileusis (LASIK) treatments using the EX500 laser (Alcon Laboratories, Inc) at ambient temperatures of 18, 20, and 22 °C. Ablation interruption was performed for 1, 2, 3, 4, and 5 seconds at the 10th second of the treatment of -9.
J Refract Surg
September 2025
Purpose: To compare postoperative vault measurements between horizontal and vertical fixation of the Implantable Collamer Lens (ICL) (KS-AquaPORT; STAAR Surgical) when its size is determined using the KS formula.
Methods: This retrospective study analyzed 2,343 eyes from 1,275 patients who underwent myopic ICL implantation. Pre-operative anterior segment optical coherence tomography (AS-OCT) (CASIA 2; Tomey Corporation) was performed in both horizontal and vertical orientations.
J Refract Surg
September 2025
From the Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany and.
Purpose: To evaluate intraocular lens (IOL) power calculation of a non-diffractive extended depth of focus (EDOF) IOL after myopic laser in situ keratomileusis (LASIK) without historical data.
Methods: In this consecutive case series, patients who had undergone lens surgery with implantation of a non-diffractive EDOF IOL after myopic laser in situ keratomileusis (LASIK) at the Department of Ophthalmology, University Hospital Frankfurt, Frankfurt, Germany, were included. Preoperative assessments included biometry and tomography using Scheimpflug technology (Pentacam; Oculus Optikgeräte GmbH).
Acta Ophthalmol
September 2025
Santen SA, Amsterdam, Netherlands.
Purpose: This study aimed to investigate the prevalence, healthcare resource utilization (HCRU) and associated costs of myopia in Germany, comparing mild/moderate and high myopia across various age groups using real-world data.
Methods: A retrospective cross-sectional study was conducted using data from the WIG2 benchmark database. Patients with a diagnosis of myopia (ICD-10-GM H52.