A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Accuracy of Intraocular Lens Calculation in a Non-diffractive Extended Depth of Focus Intraocular Lens After Myopic LASIK. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To evaluate intraocular lens (IOL) power calculation of a non-diffractive extended depth of focus (EDOF) IOL after myopic laser in situ keratomileusis (LASIK) without historical data.

Methods: In this consecutive case series, patients who had undergone lens surgery with implantation of a non-diffractive EDOF IOL after myopic laser in situ keratomileusis (LASIK) at the Department of Ophthalmology, University Hospital Frankfurt, Frankfurt, Germany, were included. Preoperative assessments included biometry and tomography using Scheimpflug technology (Pentacam; Oculus Optikgeräte GmbH). Seven IOL calculation formulas for use in eyes after myopic LASIK have been analyzed: Potvin-Hill-Shammas-PM, OKULIX ray-tracing, PEARL-DGS and PEARL-DGS with posterior radial curvature, Barrett True-K No History with measured and predicted posterior corneal astigmatism, Hoffer QST, and EVO 2.0. The last three formulas were additionally calculated using the European Society of Cataract and Refractive Surgery (ESCRS) online calculator. Spherical equivalent prediction errors were analyzed using an established online tool (Eyetemis).

Results: Thirty-four eyes of 34 patients were enrolled. Trueness of all formulas was high, with no significant difference from zero, except for OKULIX ray-tracing (-0.40 ± 0.60, < .01). No statistically significant differences in accuracy were found, with more than 59% of eyes within ±0.50 diopters and more than 85% within ±1.00 diopters for all formulas. Similar results were found between the formulas included in the ESCRS calculator when using the recommended IOL constants or constants from the IOLcon database.

Conclusions: A comparison of ray-tracing with other IOL calculation formulas revealed no substantial advantage for the former, resulting in comparable outcomes. Using the ESCRS calculator yielded comparable good results.

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20250707-07DOI Listing