Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Mechanical forces are essential for the function of key organs, including the bladder, bowel, heart, and lung<1/sup>. These organs often encounter excessive or dysregulated mechanical forces, which are associated with pathological conditions. However, the key regulators of mechanotransduction remain poorly understood. As an example of how excessive mechanical force imposed on airway epithelia could lead to mechanotransduction<2/sup> that alters the transcriptome<3/sup> and secretome<4/sup> and induces cell death<5/sup>, all of which contribute to disease progression<6,7/sup>, we used human airway epithelial cells in air-liquid interface culture to mimic bronchoconstriction. We show that Hic-5, a focal adhesion adaptor protein, functions as a key regulator of mechanoresponses in the airway. Hic-5 expression is significantly induced in airway basal cells following mechanical compression or bronchoconstriction. Hic-5 knockdown using antisense oligonucleotides protects against stress fiber formation and abolishes approximately 70% of transcripts differentially regulated by mechanical compression. Moreover, Hic-5 deficiency attenuates secretion of ET-1, a potent bronchoconstrictor. Our data show that during an asthma exacerbation, Hic-5 reinforces a vicious cycle of bronchoconstriction through the secretion of ET-1. We establish Hic-5 as a critical link between mechanical stress and epithelial activation in human disease, implicating dysregulated mechanical forces as active drivers of disease progression with therapeutic relevance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12060975PMC
http://dx.doi.org/10.21203/rs.3.rs-6498980/v1DOI Listing

Publication Analysis

Top Keywords

mechanical forces
12
mechanical
8
mechanical force
8
vicious cycle
8
cycle bronchoconstriction
8
dysregulated mechanical
8
disease progression
8
bronchoconstriction hic-5
8
mechanical compression
8
secretion et-1
8

Similar Publications

Background: Coronal wedge insoles are commonly prescribed to mitigate musculoskeletal disorders, yet their static-standing kinematic and kinetic effects on lower extremity joints remain insufficiently understood.

Methods: This cross-sectional experimental study included 15 healthy older adults (mean 64.9 ± 6.

View Article and Find Full Text PDF

Tunable Multistate Mechanoresistance in a Single-Molecule Junction Incorporating Energy-Dissipative Structures.

Angew Chem Int Ed Engl

September 2025

Stoddart Institute of Molecular Science, Department of Chemistry, Zhejiang University, Hangzhou, 310058, P.R. China.

Mechanoresponsive molecular devices are capable of exhibiting dynamic responses to external mechanical stimuli, enabling applications in smart materials, nano-devices, and flexible electronics. However, energy conversion induced by mechanical stimuli requires efficient energy dissipation mechanisms. Traditional methods often involve bond breaking or incomplete energy release, which can lead to device failure during continuous operations.

View Article and Find Full Text PDF

New insights to B cell tolerance involving the mechanosensitive ion channel Piezo1.

BMB Rep

September 2025

Department of Microbiology and Immunology, Yonsei University College of Medicine, Seoul, 03722, Republic of Korea; Brain Korea 21 PLUS Project for Medical Sciences, Yonsei University College of Medicine, Seoul, 03722, Republic of Korea; Institute for Immunology and Immunological Diseases, Yonsei Uni

B cell tolerance is critical for preventing autoimmunity, yet the mechanisms by which B cells discriminate self from non-self antigens remain incompletely understood. While early findings emphasize the role of classical antigen-mediated BCR signaling strength by varying antigen formats, emerging evidence highlights the importance of mechanical cues during antigen recognition. This review explores how mechanosensitive ion channels, particularly Piezo1, contribute to B cell activation and tolerance by integrating physical forces at the immune synapse.

View Article and Find Full Text PDF

Adhesion-based cell sorting platform using on-chip centrifugation.

Lab Chip

September 2025

Department of Mechanical Systems Engineering, Graduate School of Systems Design, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji, Tokyo, 192-0397, Japan.

Cell sorting is an important fundamental process for the selection and purification of target cell types for cell analysis in the life sciences and medical fields. In particular, demand is increasing for high-throughput cell sorting technology for the analysis of rare cells. Toward this end, we developed a centrifugal force-based cell sorting technique that relies on the adhesion force of cells as a marker.

View Article and Find Full Text PDF

Effect of forefoot strike and toe-out running on hip contact forces: A musculoskeletal modelling-based study.

J Biomech

September 2025

Human Movement Laboratory, School of Health Sciences, Western Sydney University, Campbelltown, NSW, Australia; Translational Health Research Institute, School of Health Sciences, Western Sydney University, Campbelltown, NSW, Australia.

Hip osteoarthritis (OA) is an increasingly significant public health concern, contributing to substantial economic and societal burden worldwide. Emerging evidence suggests that running may promote cartilage health through optimal joint loading. However, it remains unclear how modifications to running posture, such as altering footstrike patterns or adjusting foot progression angles, affect hip contact forces (HCF).

View Article and Find Full Text PDF