Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Incisional hernias reflect a common complication after abdominal surgery. Main treatment consists of defect closure and mesh insertion using the sublay method. The aim of the present study was to assess the association of mesh fixation to patients' outcome.

Methods: Using the Herniamed registry, data from 13'452 incisional hernia repairs were analyzed retrospectively. Three groups of patients were compared: those with mesh fixation (n = 9'986), those with self-fixing meshes (n = 2'725), and those without mesh fixation (n = 741). Postoperative complications, recurrence and postoperative pain scores were assessed over a follow-up period of one year postoperatively.

Results: Taking into account that patients without mesh fixation had smaller defects and were treated with smaller meshes indicating non-equivalent groups, postoperative complications (general, intra- and postoperative complications, as well as complication-related reoperations), were similar among groups except that self-fixing meshes showed a lower general complication rate compared to fixed meshes (OR = 0.733 [0.579; 0.929]; p = 0.010). Mesh fixation had no relation to recurrence rate. Self-fixating meshes were associated with increased pain at rest rate (OR = 1.325 [1.156; 1.518]; p < 0.001), pain on exertion rate (OR = 1.255 [1.125; 1.400], p < 0.001) and chronic pain requiring treatment (OR = 1.271 [1.086; 1.488], p = 0.003) compared to fixed meshes. Self-fixating (OR = 1.675 [1.322; 2.120], p < 0.001) and fixed meshes (OR = 1.334 [1.069; 1.666], p = 0.011) were associated to increased pain on exertion rate compared to non-fixed meshes.

Conclusion: It appears that mesh fixation can be omitted during sublay incisional hernia repair.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12018522PMC
http://dx.doi.org/10.1007/s00423-025-03714-8DOI Listing

Publication Analysis

Top Keywords

mesh fixation
24
postoperative complications
12
incisional hernia
8
self-fixing meshes
8
mesh
7
fixation
5
meshes
5
fixation incisional
4
hernia repair
4
repair open
4

Similar Publications

De Garengeot hernia, characterized by appendiceal incarceration within a femoral canal hernia sac, is a rare condition with high risks of strangulation. Traditional open repair remains standard, but laparoscopic approaches offer minimally invasive alternatives. However, limited evidence exists on combining laparoscopic transabdominal preperitoneal (TAPP) with biologic mesh for this condition.

View Article and Find Full Text PDF

Objective: To establish a two-segment vertebrectomy model using the finite element method, and to measure and compare the biomechanical properties of the lower cervical anterior transpedicular root screw (ATPRS) plate system, lower cervical anterior pedicle screw (ATPS) plate system, and lower cervical anterior cervical locked-plate (ACLP) system on this model.

Methods: CT data of the cervical spine (C-T) from a 34-year-old healthy adult male volunteer were collected. A nonlinear complete model of the lower cervical spine (C-C) was established using Mimics 10.

View Article and Find Full Text PDF

Surgical repair of orbital fractures comes with risks. One rare risk is interference with the actions of the superior oblique tendon-muscle complex causing an acquired Brown syndrome. We present the case of a 45-year-old man who developed acquired Brown syndrome after undergoing repair of a large orbital floor and medial orbital wall fracture using a titanium mesh implant.

View Article and Find Full Text PDF

An anisotropic cardiac patch with barbed microneedles for enhanced tissue anchorage and myocardial repair.

Acta Biomater

August 2025

Shanghai Frontiers Science Center of Advanced Textiles, College of Textiles, Donghua University, Shanghai 201620, China; Key Laboratory of Textile Science &Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China; Key Laboratory of Textile Industry for Biome

Microneedle patches can penetrate the myocardium to facilitate integration with cardiac tissue, offering a promising approach for myocardial infarction (MI) repair. However, their clinical translation has been hindered by insufficient fixation stability during cardiac contractions and mismatch with myocardial anisotropy. To address these challenges, a bioinspired three-dimensional cardiac patch integrating barbed microneedles and an anisotropic lightweight mesh was designed.

View Article and Find Full Text PDF

BackgroundThere is currently insufficient evidence to determine whether lightweight or heavyweight mesh is the better choice for ventral hernias. Recurrence and postoperative pain are associated with biomechanical responses such as inflammation, foreign body reaction, cell ingrowth, and tensile strength, which can be examined in animal studies. This study aimed to compare the biomechanical differences between light- and heavyweight meshes in animal models.

View Article and Find Full Text PDF