Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Unlabelled: Longitudinal imaging of 3D cell cultures like tumor organoids and spheroids offers crucial insights into cancer progression and treatment. However, spatial displacement during time-course imaging, caused by matrix detachment or experimental artifacts, can confound analyses. Existing computational methods struggle to address this issue. We present a new algorithm to evaluate data integrity and rectify mislabeling in longitudinal imaging of 3D cell culture. Our algorithm integrates permutation-based optimization with Procrustes analysis. By using X and Y coordinates of images, it accurately reorders, matches, and aligns object positions across time points, correcting for rotation, translation, and small movements. Validation with simulated data confirmed its accuracy and robustness. Applied to longitudinal imaging of tumor spheroids, our algorithm revealed frequent displacement amongst the spheroids between time points and corrected many mislabeled images. This computationally efficient and adaptable method needs no experimental adjustments and presents a readily accessible solution for data quality control.

Motivation: Three-dimensional (3D) in vitro models, such as tumor organoids and spheroids embedded in an extracellular matrix, are increasingly vital for studying normal and disease biology, including drug responses. A key advantage of these models is that imaging platforms can perform continuous longitudinal imaging to track phenotypic changes. However, common issues in 3D techniques, such as matrix shifts during experimental setup or image capture, can introduce technical artifacts that affect downstream analyses. Currently, no automated analytical approaches exist for assessing or correcting technical artifacts. Here, we introduce a robust, automated algorithm for assessing the quality of time-course image data and, in some cases, correcting object mislabeling to enable accurate tracking of individual spheroids over time. This approach relies only on image metadata, requiring no experimental modifications. It offers a readily implementable solution for improving data integrity and reproducibility and enhancing the reliability of longitudinal 3D cell culture studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11996402PMC
http://dx.doi.org/10.1101/2025.03.31.646437DOI Listing

Publication Analysis

Top Keywords

longitudinal imaging
16
time-course imaging
8
imaging cell
8
tumor organoids
8
organoids spheroids
8
data integrity
8
cell culture
8
time points
8
spheroids time
8
technical artifacts
8

Similar Publications

MRI Assessment of Radiation-Induced Delayed-Onset Microstructural Gray Matter Changes in Nasopharyngeal Carcinoma Patients.

J Magn Reson Imaging

September 2025

School of Biomedical Engineering, Guangdong Provincial Key Laboratory of Medical Image Processing and Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.

Background: The dynamic progression of gray matter (GM) microstructural alterations following radiotherapy (RT) in patients, and the relationship between these microstructural abnormalities and cortical morphometric changes remains unclear.

Purpose: To longitudinally characterize RT-related GM microstructural changes and assess their potential causal links with classic morphometric alterations in patients with nasopharyngeal carcinoma (NPC).

Study Type: Prospective, longitudinal.

View Article and Find Full Text PDF

Replication-competent adenovirus reporters utilizing endogenous viral expression architecture.

J Virol

September 2025

Genome Regulation and Cell Signaling, Ellen and Ronald Caplan Cancer Center, The Wistar Institute, Philadelphia, Pennsylvania, USA.

Unlabelled: Adenoviruses are double-stranded DNA viruses widely used as platforms for vaccines, oncolytics, and gene delivery. However, tools for studying adenoviral gene expression in real time during infection remain limited. Here, we describe a set of fluorescent and bioluminescent reporter viruses built using the modular AdenoBuilder reverse genetics system and informed by high-resolution maps of Ad5 transcription.

View Article and Find Full Text PDF

Mid-field (0.55-T) MRI may offer an alternative to higher field strengths for pancreatic intraductal papillary mucinous neoplasms (IPMNs) surveillance given high-quality MRCP sequences enabled by longer T2 relaxation times and greater patient comfort resulting from a larger bore and reduced acoustic noise. However, SNR is lower at 0.

View Article and Find Full Text PDF

Optical imaging offers high sensitivity and specificity for noninvasive cancer detection, but conventional techniques suffer from limited probe accumulation, tissue autofluorescence, and poor depth resolution. Afterglow luminescence overcomes autofluorescence by emitting persistent light after excitation, yet its utility in vivo remains hindered by weak tumor enrichment and two-dimensional readouts lacking spatial context. Here, we report luminescent-magnetic nanoparticles (LM-NPs) coencapsulating luminescent trianthracene (TA) molecules and iron oxide cores within the amphiphilic polymer pluronic-F127.

View Article and Find Full Text PDF

Cognitive impairment and dementia, including Alzheimer's disease (AD), pose a global health crisis, necessitating non-invasive biomarkers for early detection. This review highlights the retina, an accessible extension of the central nervous system (CNS), as a window to cerebral pathology through structural, functional, and molecular alterations. By synthesizing interdisciplinary evidence, we identify retinal biomarkers as promising tools for early diagnosis and risk stratification.

View Article and Find Full Text PDF