A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Lab-on-Robot: Unmanned Mass Spectrometry Robot for Direct Sample Analysis in Hazardous and Radioactive Environments. | LitMetric

Lab-on-Robot: Unmanned Mass Spectrometry Robot for Direct Sample Analysis in Hazardous and Radioactive Environments.

Anal Chem

College of Environment and Climate, Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, and Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou

Published: May 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Onsite, safe, and reliable mass spectrometry (MS) analysis of hazardous and radioactive samples plays a crucial role in timely chemical emergency management and response in real environments. The current study reports the development of a smart MS robot by integrating miniature MS, quadruped robot, switchable robotic arm sampler, and direct ionization for remote-controlled chemical analysis of complex samples in inaccessible hazardous and radioactive environments. High automation and excellent analytical performance have been achieved in the real-time analysis of volatile toxic substances in air and onsite detection of explosive particles in air aerosols. Successful detection of hazardous compounds has been performed from raw wastewater. The chemical analysis of radioactive ore samples has also been demonstrated. Low limits of detection at ng/g or ng/mL (signal-to-noise ratio, S/N = 3) and good relative standard deviation (RSD < 12.0%, = 6) were obtained by the MS robot for analyzing different gaseous, aerosol, liquid, and solid samples. The remote detection results of the MS robot were further validated. The reported study encourages the future development of a smart lab-on-robot, which functions with smart operation to replace the traditional laboratory procedures for MS analysis of dangerous chemical and environmental samples.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.5c01237DOI Listing

Publication Analysis

Top Keywords

hazardous radioactive
12
mass spectrometry
8
analysis hazardous
8
radioactive environments
8
development smart
8
chemical analysis
8
analysis
6
robot
5
samples
5
lab-on-robot unmanned
4

Similar Publications