98%
921
2 minutes
20
For traditional moiré-based lithography alignment technology, which is widely used in proximity lithography systems, complex alignment marks with larger areas are employed to achieve high-precision misalignment detection. However, every inch of space on the wafer is extremely precious in practice, leaving minimal space for alignment marks. Therefore, employing small-area alignment marks in lithography systems will be a very challenging task with considerable potential in the future. The primary challenge is that existing frequency-based analytical algorithms struggle to achieve misalignment values with high-precision from moiré fringe images generated by small-area marks. To address this challenge, a spatial and frequency information fusion neural network (SFFN) is proposed for processing the moiré fringe images. With SFFN, the area of the alignment mark can be reduced by 2/3, and the average error of SFFN is less than 1 nm on the test dataset.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.543600 | DOI Listing |
J Biomed Opt
September 2025
Leibniz University Hannover, Hannover Centre for Optical Technologies, Hannover, Germany.
Significance: Melanoma's rising incidence demands automatable high-throughput approaches for early detection such as total body scanners, integrated with computer-aided diagnosis. High-quality input data is necessary to improve diagnostic accuracy and reliability.
Aim: This work aims to develop a high-resolution optical skin imaging module and the software for acquiring and processing raw image data into high-resolution dermoscopic images using a focus stacking approach.
PLoS One
September 2025
College of Landscape Architecture and Art, Northwest Agriculture and Forestry University, Xianyang, China.
This study investigates the spatial and temporal distribution and the influencing factors of 579 cultural heritage sites along the Qin-Shu Ancient Road in Shaanxi Province, employing kernel density estimation, buffer analysis, and geographic detectors. Three key findings emerge: (1) The spatial pattern is characterized by a "line-belt-core" structure, with a belt-like aggregation along the Xi'an-Baoji-Hanzhong axis. Core concentrations are found in Xi'an (181 sites), Hanzhong (159 sites), and Ankang (122 sites), with secondary concentrations in Baoji (72 sites) and Shangluo (36 sites).
View Article and Find Full Text PDFPlant Physiol
September 2025
Department of Biochemistry, Purdue University, West Lafayette, IN 47907, USA.
In this study, we used stable isotope labeling coupled with reversed-phase HPLC-MS to annotate the origin of metabolite features in Arabidopsis (Arabidopsis thaliana) (Columbia-0) seedling rosettes and stems. Using this strategy, a total of 1,240 metabolite features were shown to be derived from 15 amino acids, and these represented 10% to 30% of the total ion counts detected by untargeted LC-MS. The amino acid-derived metabolomes (AADMs) of rosettes and stems exhibited differing patterns of accumulation.
View Article and Find Full Text PDFBMC Ophthalmol
September 2025
Department of Ophthalmology, Tongji Medical College, The Central Hospital of Wuhan, Huazhong University of Science and Technology, No 26 Shengli Street, Wuhan, 430014, China.
Background: Manual and digital-assisted marking are the two main marking methods used for toric intraocular lens (IOL) in cataract surgery. However, there is a lack of consensus regarding the consistency in accuracy for these two methods. This meta-analysis aimed to compare and evaluate the accuracy of digital and manual marking techniques for toric IOL alignment during cataract surgery.
View Article and Find Full Text PDFLangmuir
September 2025
Laboratory of Quantum Physics LR 18 ES 18, Faculty of Sciences of Monastir, Monastir 5000, Tunisia.
Using the grand canonical framework, we investigate the key physicochemical properties governing atrazine adsorption on MgO/FeO-based porous carbon materials. Adhesion isotherms were modeled using theoretical frameworks aligned with experimental data through specific fitting metrics. Error metrics (, RSS, , and reduced χ) support the monolayer, single-energy model as most representative of molecular-scale adsorption.
View Article and Find Full Text PDF