Article Abstract

Miniature bioelectronic implants promise revolutionary therapies for cardiovascular and neurological disorders. Wireless power transfer (WPT) is a significant method for miniaturization, eliminating the need for bulky batteries in today's devices. Despite successful demonstrations of millimetric battery-free implants in animal models, the robustness and efficiency of WPT are known to degrade significantly under misalignment incurred by body movements, respiration, heart beating, and limited control of implant orientation during surgery. This paper presents an omnidirectional WPT platform for millimetric bioelectronic implants, employing the emerging magnetoelectric (ME) WPT modality, and "magnetic field steering" technique based on multiple transmitter (TX) coils. To accurately sense the weak coupling in a miniature implant and adaptively control the multi-coil TX array in a closed loop, we develop an Active Echo (AE) scheme using a tiny coil on the implant. Our prototype comprises a fully integrated 14.2mm implantable stimulator embedding a custom low-power System-on-Chip (SoC) powered by an ME film, a transmitter with a custom three-channel AE RX chip, and a multi-coil TX array with mutual inductance cancellation. The AE RX achieves -161dBm/Hz input-referred noise with 64dB gain tuning range to reliably sense the AE signal, and offers fast polarity detection for driver control. AE simultaneously enhances the robustness, efficiency, and charging range of ME WPT. Under 90° rotation from the ideal position, our omnidirectional WPT system achieves 6.8× higher power transfer efficiency (PTE) than a single-coil baseline. The tracking error of AE negligibly degrades the PTE by less than 2% from using ideal control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11736903PMC
http://dx.doi.org/10.1109/jssc.2024.3464533DOI Listing

Publication Analysis

Top Keywords

power transfer
12
wireless power
8
bioelectronic implants
8
robustness efficiency
8
omnidirectional wpt
8
multi-coil array
8
wpt
6
omnidirectional wireless
4
transfer millimetric
4
millimetric magnetoelectric
4

Similar Publications

Background: Circumcision is a widely practiced procedure with cultural and medical significance. However, certain penile abnormalities-such as hypospadias or webbed penis-may contraindicate the procedure and require specialized care. In low-resource settings, limited access to pediatric urologists often leads to missed or delayed diagnoses.

View Article and Find Full Text PDF

The PROtective VEntilation (PROVE) Network is a globally-recognized collaborative research group dedicated to advancing research, education, and collaboration in the field of mechanical ventilation. Established to address critical questions in intraoperative and intensive care ventilation, the network focuses on improving outcomes for patients undergoing mechanical ventilation in diverse settings, including operating rooms, intensive care units, burn units, and resource-limited environments in low- and middle-income countries. The PROVE Network is committed to generating high-quality evidence through a comprehensive portfolio of investigations, including randomized clinical trials, observational research, and meta-analyses.

View Article and Find Full Text PDF

Improving Door-In-Door-Out Times for STEMI Transfer Patients: Impact of a Protocolized Autolaunch Process.

JACC Case Rep

July 2025

Department of Emergency Medicine, McGovern Medical School at the University of Texas Health Science Center at Houston (UTHealth Houston), Houston, Texas, USA; Texas Emergency Medicine Research Center, Houston, Texas, USA.

Background: The timely transfer of patients with ST-segment elevation myocardial infarction (STEMI) to percutaneous coronary intervention-capable centers is critical for improving outcomes. Although the American Heart Association recommends a door-in-door-out (DIDO) time of ≤30 minutes, national compliance remains low.

Project Rationale: At Harris Health, no patients with STEMI met this benchmark before 2022.

View Article and Find Full Text PDF

A radio frequency emitter design for the low-frequency regime in atomic experiments.

Rev Sci Instrum

September 2025

International Center for Quantum Materials, School of Physics, Peking University, Beijing 100871, China.

Radio frequency (RF) control is a key technique in cold atom experiments. We present a compact and efficient RF circuit based on a capacitive transformer network, where a low-frequency coil operating up to 30 MHz serves as both an intrinsic inductor and a power-sharing element. The design enables high current delivery and flexible impedance matching across a wide frequency range.

View Article and Find Full Text PDF

Polymer-derived ceramics are a versatile class of multifunctional materials synthesized the high-temperature treatment of a preceramic polymer. In this work, we report the synthesis of a vanadium carbide-embedded carbonaceous hybrid by pyrolyzing a modified preceramic polymer incorporating vanadium acetylacetonate in a polysilsesquioxane followed by hydrofluoric acid etching. The structural and microscopic characterisation confirmed the uniform distribution of nanoparticulate vanadium carbide in the matrix.

View Article and Find Full Text PDF