98%
921
2 minutes
20
Background: Computational modeling is used to optimize transcranial electrical stimulation (tES) approaches, and the precision of these models is dependent on their anatomical accuracy. We are unaware of any computational modeling of tES that has included cranial sutures.
Objectives: The aims of the study were to review the literature on the timing of closure of the coronal and squamous sutures, which are situated under electrode placements used in tES; to review the literature regarding differences in skull and suture conductivity and to determine a more accurate conductivity for sutures; and to identify magnetic resonance image (MRI) techniques that could be used to detect cranial sutures.
Methods: A scoping review of medical literature was conducted. We conducted computational modeling of a cranial bone plug using COMSOL Multiphysics finite element software, utilizing methodology and results from a previous study. We assessed use of the "3D Slicer" software to identify sutures in routine T1-weighted MRI scans.
Results: Reports from forensic examinations and computed tomography (CT) scans showed suture closure does not correlate with age. Our computational modeling determined a cranial suture conductivity of 0.32 S/m, which is much higher than for skull (compact skull 0.004 S/m, standard trilayer 0.013 S/m). 3D slicer enabled rapid and precise identification of the anatomy and location of cranial sutures.
Conclusions: Cranial sutures persist throughout the lifespan and have a far higher conductivity than skull bone. Cranial sutures can be localized quickly and precisely using a combination of MRI and readily available modeling software. Sutures should be included in tES computational modeling and electroencephalography source imaging to improve the accuracy of results.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12105966 | PMC |
http://dx.doi.org/10.1097/YCT.0000000000001079 | DOI Listing |
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFBMC Ecol Evol
September 2025
Lehrstuhl für Zoologie, TUM School of Life Sciences, Technical University of Munich, Liesel-Beckmann Strasse 4, Freising, 85354, Germany.
Accurate three-dimensional localisation of ultrasonic bat calls is essential for advancing behavioural and ecological research. I present a comprehensive, open-source simulation framework-Array WAH-for designing, evaluating, and optimising microphone arrays tailored to bioacoustic tracking. The tool incorporates biologically realistic signal generation, frequency-dependent propagation, and advanced Time Difference of Arrival (TDoA) localisation algorithms, enabling precise quantification of both positional and angular accuracy.
View Article and Find Full Text PDFMetabolomics
September 2025
Toxalim (Research Centre in Food Toxicology), Université de Toulouse, INRAE, ENVT, INP-Purpan, UPS, Toulouse, France.
Introduction: Initially developed for transcriptomics data, pathway analysis (PA) methods can introduce biases when applied to metabolomics data, especially if input parameters are not chosen with care. This is particularly true for exometabolomics data, where there can be many metabolic steps between the measured exported metabolites in the profile and internal disruptions in the organism. However, evaluating PA methods experimentally is practically impossible when the sample's "true" metabolic disruption is unknown.
View Article and Find Full Text PDFAnn Biomed Eng
September 2025
Department of Mechanical Engineering, Koc University, Rumeli Feneri Campus, Sarıyer, 34450, Istanbul, Turkey.
Purpose: The design and development of ventricular assist devices have heavily relied on computational tools, particularly computational fluid dynamics (CFD), since the early 2000s. However, traditional CFD-based optimization requires costly trial-and-error approaches involving multiple design cycles. This study aims to propose a more efficient VAD design and optimization framework that overcomes these limitations.
View Article and Find Full Text PDFCommun Biol
September 2025
Division of Neurobiology, Faculty of Biology, Ludwig-Maximilians-Universität München, Planegg - Martinsried, Germany.
The internal resistance of axons to ionic current flow determines action potential conduction velocity. Although mitochondria support axonal function, axons have been modeled as organelle-free cables, and mitochondrial impact on conduction velocity, specifically by increasing internal resistance, remains understudied. We combine computational modeling and electron microscopy of forebrain premotor axons controlling birdsong production.
View Article and Find Full Text PDF