Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Unhealthy lifestyles negatively impact the prognosis and outcomes of cardiovascular disease. The objective of this study is to examine the effects of smart healthcare technology in assisting physicians with monitoring and improving patient lifestyles, as well as adjusting treatment plans on carotid intima-media thickness (IMT) and thrombotic markers during the therapeutic management of hypertension. Furthermore, we compared the efficacy of smart healthcare interventions with conventional hospital-based follow-up in ameliorating cardiovascular complications in patients with established hypertension. The goal is to elucidate the optimal timing for clinical interventions and to develop personalized treatment plans to enhance the long-term prognosis of patients with cardiovascular disease.

Methods: A stratified sample of 174 patients with established hypertension from two villages in southeastern China was selected. The study cohort comprised 85 participants in the smart healthcare intervention group and 89 participants in the regular follow-up control group. Changes in median levels of IMT, von Willebrand factor (vWF), P-selectin (P-S), body mass index (BMI), blood pressure, and cholesterol were assessed before and after the study period. Comparative analysis of changes in IMT, vWF, P-S, blood pressure, and cholesterol between the two groups was conducted over the study period.

Results: The intervention group demonstrated significantly greater improvements in IMT, vWF, and P-S levels compared to the control group (P < 0.05). At the 12-month follow-up (T12), blood pressure, BMI, total cholesterol, IMT, P-S, and vWF levels were significantly lower in the intervention group than in the control group (P < 0.05). The reduction in IMT was particularly notable, with the intervention group revealing a statistically significant improvement compared to the control group (P < 0.001).

Conclusion: The smart healthcare intervention model resulted in more significant improvements in IMT and thrombotic markers compared to the traditional hospital follow-up model. Patients using the smart blood pressure monitors exhibited significantly lower levels of IMT, vWF, and P-S compared to their pre-intervention levels.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocn.2024.110925DOI Listing

Publication Analysis

Top Keywords

smart healthcare
20
intervention group
16
control group
16
blood pressure
16
thrombotic markers
12
imt vwf
12
vwf p-s
12
carotid intima-media
8
intima-media thickness
8
treatment plans
8

Similar Publications

Localized Gradient Conductivity Enabled Ultrasensitive Flexible Tactile Sensors with Ultrawide Linearity Range.

Adv Mater

September 2025

Key Laboratory of Low Dimensional Quantum Structures and Quantum Control of Ministry of Education, School of Physics and Electronics, Hunan Normal University, Changsha, 410081, China.

The high sensitivity and wide linearity are crucial for flexible tactile sensors in adapting to diverse application scenarios with high accuracy and reliability. However, conventional optimization strategies of constructing microstructures suffer from the mutual restriction between the high sensitivity and wide linearity. Herein, a novel design of localized gradient conductivity (LGC) with partly covered low-conductivity (low-σ) carbon/Polydimethylsiloxane layer on high-conductivity (high-σ) silver nanowires film upon the micro-dome structure is proposed.

View Article and Find Full Text PDF

Feasibility, Acceptability, and Preliminary Outcomes of a Mobile Adaptation of a Relational Savoring Intervention to Prevent Loneliness in College Students: Mixed Methods Pilot Study.

JMIR Form Res

September 2025

Department of Psychological Science, School of Social Ecology, University of California, Irvine, 4201 Social and Behavioral Sciences Gateway, Irvine, CA, 92697, United States, 1 203-887-8857.

Background: Rates of loneliness have risen sharply since the onset of the COVID-19 pandemic, largely due to disruptions in social relationships and daily routines, with college students experiencing some of the greatest increases. While prevention programs targeting loneliness have been developed, their success has been limited. One promising approach may lie in enhancing the quality of existing relationships rather than simply increasing social interactions during periods of acute loneliness.

View Article and Find Full Text PDF

Vagus nerve stimulation (VNS) is a promising therapy for neurological and inflammatory disorders across multiple organ systems. However, conventional rigid interfaces fail to accommodate dynamic mechanical environments, leading to mechanical mismatches, tissue irritation, and unstable long-term interfaces. Although soft neural interfaces address these limitations, maintaining mechanical durability and stable electrical performance remains challenging.

View Article and Find Full Text PDF

Strain sensors have received considerable attention in personal healthcare due to their ability to monitor real-time human movement. However, the lack of chemical sensing capabilities in existing strain sensors limits their utility for continuous biometric monitoring. Although the development of dual wearable sensors capable of simultaneously monitoring human motion and biometric data presents significant challenges, the ability to fabricate these sensors with geometries tailored to individual users is highly desirable.

View Article and Find Full Text PDF

Electroactive polymer (EAP) artificial muscles are gaining attention in robotic control technologies. Among them, the development of self-sensing actuators that integrate sensing mechanisms within artificial muscles is highly anticipated. This study aimed to evaluate the accuracy and precision of the sensing capabilities of the e-Rubber (eR), an artificial muscle developed by Toyoda Gosei Co.

View Article and Find Full Text PDF