98%
921
2 minutes
20
Spectral Photon Counting Computed Tomography (SPCCT), a ground-breaking development in CT technology, has immense potential to address the persistent problem of metal artefacts in CT images. This study aims to evaluate the potential of Mars photon-counting CT technology in reducing metal artefacts. It focuses on identifying and quantifying clinically significant materials in the presence of metal objects. A multi-material phantom was used, containing inserts of varying concentrations of hydroxyapatite (a mineral present in teeth, bones, and calcified plaque), iodine (used as a contrast agent), CT water (to mimic soft tissue), and adipose (as a fat substitute). Three sets of scans were acquired: with aluminium, with stainless steel, and without a metal insert as a reference dataset. Data acquisition was performed using a Mars SPCCT scanner (Microlab 5×120); operated at 118 kVp and 80 μA. The images were subsequently reconstructed into five energy bins: 7-40, 40-50, 50-60, 60-79, and 79-118 keV. Evaluation metrics including signal-to-noise ratio (SNR), linearity of attenuation profiles, root mean square error (RMSE), and area under the curve (AUC) were employed to assess the energy and material-density images with and without metal inserts. Results show decreased metal artefacts and a better signal-to-noise ratio (up to 25%) with increased energy bins as compared to reference data. The attenuation profile also demonstrated high linearity (R2 >0.95) and lower RMSE across all material concentrations, even in the presence of aluminium and steel. Material identification accuracy for iodine and hydroxyapatite (with and without metal inserts) remained consistent, minimally impacting AUC values. For demonstration purposes, the biological sample was also scanned with the stainless steel volar implant and cortical bone screw, and the images were objectively assessed to indicate the potential effectiveness of SPCCT in replicating real-world clinical scenarios.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11398698 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0308658 | PLOS |
Small Methods
September 2025
School of Physics and Optoelectronics, South China University of Technology, Wushan Road 381, Guangzhou, 510640, China.
Magnetic-field enhancement of the oxygen evolution reaction (OER) represents a promising route toward more efficient alkaline water electrolyzers, yet its origin remains debated due to overlapping effects of mass transport and reaction kinetics. Here, we present a general experimental strategy that employs strong forced convection to suppress uncontrolled transport arising from natural diffusion and magnetohydrodynamic (MHD) flows. Using polycrystalline Au electrodes, we show that this approach resolves subtle OER variations under controlled flow and field conditions.
View Article and Find Full Text PDFActa Oncol
September 2025
Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
Background And Purpose: Accurate stopping-power ratio (SPR) estimation is crucial for proton therapy planning. In brain cancer patients with metal clips, SPR accuracy may be affected by high-density materials and imaging artefacts. Dual-energy CT (DECT)-based methods have been shown to improve SPR accuracy.
View Article and Find Full Text PDFNanophotonics
August 2025
Department of Electronic Engineering, Hanyang University, Seoul, 04763, Republic of Korea.
Under-display camera (UDC) systems enable full-screen displays in smartphones by embedding the camera beneath the display panel, eliminating the need for notches or punch holes. However, the periodic pixel structures of display panels introduce significant optical diffraction effects, leading to imaging artifacts and degraded visual quality. Conventional approaches to mitigate these distortions, such as deep learning-based image reconstruction, are often computationally expensive and unsuitable for real-time applications in consumer electronics.
View Article and Find Full Text PDFThe present article describes a dental implant planning workflow to solve the CBCT artifact problem. The technique uses a radiopaque 3D-printed tray to take impressions and complete data alignment of the dental arches where implants are planned. From the impressions, 3D Boolean inversion is performed to obtain the surface mesh of teeth and virtually remove the undercut of dentition mesh before an implant surgical guide is designed.
View Article and Find Full Text PDFDeep learning reconstruction (DLR) offers a variety of advantages over the current standard iterative reconstruction techniques, including decreased image noise without changes in noise texture and less susceptibility to spatial resolution limitations at low dose. These advances may allow for more aggressive dose reduction in CT imaging while maintaining image quality and diagnostic accuracy. However, performance of DLRs is impacted by the type of framework and training data used.