Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

To evaluate the effect of build direction, post-polymerization time, and aging on the fracture resistance, failure mode, margin quality and Marginal (MD) and Internal Discrepancies (ID), and degree of conversion of tridimensional (3D) printed provisional crowns using the liquid crystal display technique (LCD). A left mandibular first molar was prepared and scanned. After, a full crown was designed (ExoCad) and exported to the LCD-printer software. One hundred and eighty crowns were printed at two build directions (30°, 90°) and post-polymerized for different periods (15, 30, 45 min). Half of the samples were aged (ST) in distilled water (37 °C/90 days). The marginal quality of the crowns was evaluated by the Schriwer method under a stereomicroscope (40x). The replica technique was used to measure the MD and ID and measured under a stereomicroscope (10x), through 20 reference points defined in 5 regions: Occlusal (O), Cusp (CP), Axial (AX), Chamfer (CH), and Finish Line (F). After, the crowns were cemented onto the respective dies using temporary cement and submitted to compression test (ISO150, 1 mm/min, 100 kgf).The failure mode was classified by Burke's fracture mode. The degree of conversion was evaluated through Fourier Transform Infrared Spectroscopy. The data (μm) of MD and ID and fracture resistance (N) were subjected to ANOVA (3 factors) and Tukey's test (5%); Weibull analysis was also performed for fracture resistance data (N). For MD, ID and fracture resistance ANOVA revealed that all factors (P < .001) were significant. For aged groups, the crowns printed at 30° showed lower MD (Tukey). The O_90_30 min (172.13 μm) and O_90_15 min (170.20 μm) groups showed the highest ID values. Higher resistance values were observed for the 30_45 min (844.30 N), 30_30 min (835.35 N), and 90_30 min (820.62 N) groups (Tukey). In the margin analysis, 98.6% of the crowns printed at 30° showed smooth margins without defects. The most prevalent fracture mode (41.7%) was Burke type 5. The degree of conversion (DC) increased with increasing post-polymerization time and aging. Printing provisional crowns at 30° provided lower crown MD and ID, as well as higher fracture resistance. A post-polymerization time of 30 min resulted in higher crown fracture resistance, while aging reduced the resistance of the crowns.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10266-024-00991-5DOI Listing

Publication Analysis

Top Keywords

fracture resistance
20
build direction
8
direction post-polymerization
8
post-polymerization time
8
time aging
8
aging fracture
8
marginal internal
8
internal discrepancies
8
printed provisional
8
provisional crowns
8

Similar Publications

Background: Physical resilience-the ability to withstand, recover, or adapt after a stressor-is critical in older adults facing acute insults. We conceptualize physical resilience to comprise two distinct but related components: resistance (immediate physiological response to the stressor) and recovery (subsequent health changes). These two components were used to evaluate how individuals respond to hip fracture-a common and severe geriatric stressor.

View Article and Find Full Text PDF

Interaction between diabetes and osteoporosis: imbalance between inflammation and bone remodeling.

Osteoporos Int

September 2025

Department of Endocrinology, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, 400037, China.

Diabetes and osteoporosis are common chronic diseases worldwide, and there is a complex pathological relationship between the two. Due to hyperglycemia, insulin resistance, and accumulation of advanced glycation end products (AGEs), diabetic patients often show a higher risk of fractures. At the same time, chronic low-grade inflammation and oxidative stress caused by diabetes also play an important role in the occurrence of osteoporosis, disrupting the balance of bone remodeling.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant-supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.

Materials And Methods: Three cylinder-shaped master files (20 mm long and 11 mm wide) with varying heights (7, 11, and 15 mm) and a titanium-base (Ti-base) abutment space were designed. These designs were used to fabricate a total of 144 specimens with two AM resins indicated for definitive use (Crowntec; AM-CT and Flexcera Smile Ultra+; AM-FS), one high-impact polymer composite (breCAM.

View Article and Find Full Text PDF

Background: Surgical site infection (SSI) after surgery can cause serious sequelae in patients with tibial plateau fractures. This study aims to report the incidence and characteristics of SSI and to investigate the risk factors of SSI in adult patients with closed tibial plateau fracture, especially the relationship between SSI and preoperative hypoalbuminemia.

Methods: We retrospectively reviewed the records of adult patients with closed tibial plateau fracture who were treated at our institution from January 2016 to December 2022.

View Article and Find Full Text PDF

Background: Multiple myeloma (MM) remains a formidable clinical challenge due to its high relapse rate and resistance to existing therapies. Estrogen-related receptor gamma (ERRγ), a nuclear receptor critical for cellular energy metabolism, has been implicated in various cancers. but its role in MM remains unclear.

View Article and Find Full Text PDF