Article Abstract

High-sensitivity flow cytometers have been developed for multi-parameter characterization of single extracellular vesicles (EVs), but performance varies among instruments and calibration methods. Here we compare the characterization of identical (split) EV samples derived from human colorectal cancer (DiFi) cells by three high-sensitivity flow cytometers, two commercial instruments, CytoFLEX/CellStream, and a custom single-molecule flow cytometer (SMFC). DiFi EVs were stained with the membrane dye di-8-ANEPPS and with PE-conjugated anti-EGFR or anti-tetraspanin (CD9/CD63/CD81) antibodies for estimation of EV size and surface protein copy numbers. The limits of detection (LODs) for immunofluorescence and vesicle size based on calibration using cross-calibrated, hard-dyed beads were ∼10 PE/∼80 nm EV diameter for CytoFLEX and ∼10 PEs/∼67 nm for CellStream. For the SMFC, the LOD for immunofluorescence was 1 PE and ≤ 35 nm for size. The population of EVs detected by each system (di-8-ANEPPS/PE particles) differed widely depending on the LOD of the system; for example, CellStream/CytoFLEX detected only 5.7% and 1.5% of the tetraspanin-labelled EVs detected by SMFC, respectively, and median EV diameter and antibody copy numbers were much larger for CellStream/CytoFLEX than for SMFC as measured and validated using super-resolution/single-molecule TIRF microscopy. To obtain a dataset representing a common EV population analysed by all three platforms, we filtered out SMFC and CellStream measurements for EVs below the CytoFLEX LODs as determined by bead calibration (10 PE/80 nm). The inter-platform agreement using this filtered dataset was significantly better than for the unfiltered dataset, but even better concordance between results was obtained by applying higher cutoffs (21 PE/120 nm) determined by threshold analysis using the SMFC data. The results demonstrate the impact of specifying LODs to define the EV population analysed on inter-instrument reproducibility in EV flow cytometry studies, and the utility of threshold analysis of SMFC data for providing semi-quantitative LOD values for other flow cytometers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11322860PMC
http://dx.doi.org/10.1002/jev2.12498DOI Listing

Publication Analysis

Top Keywords

flow cytometers
16
high-sensitivity flow
12
custom single-molecule
8
single-molecule flow
8
flow cytometer
8
copy numbers
8
evs detected
8
population analysed
8
dataset better
8
threshold analysis
8

Similar Publications

Triple-negative breast cancer (TNBC) is a serious threat to lives and health. We developed a dual approach of Photodynamic therapy (PDT) and Newcastle Disease Oncolytic Virus (NDV) to mediate killing effects and anti-tumor immune effects against TNBC. In this study, we firstly verified that PDT combined with NDV effectively eliminated tumor cells.

View Article and Find Full Text PDF

Apelin-13-Mediated Upregulation of METTL3 Ameliorates Alzheimer's Disease via Inhibiting Neuroinflammation Through m6A-Dependent Regulation of lncRNA BDNF-AS.

Biomolecules

August 2025

Hunan Provincial University Key Laboratory of the Fundamental and Clinical Research on Functional Nucleic Acid, the First Clinical College, Changsha Medical University, Changsha 410219, China.

Apelin-13, a neuropeptide, has been recognized for its neuroprotective properties. Our previous study found apelin-13 improves cognitive function in Alzheimer's disease (AD) rats by inhibiting neuroinflammation through upregulation of BDNF/TrkB signaling pathway. However, the precise mechanism by which apelin-13 modulates BDNF remains unclear.

View Article and Find Full Text PDF

Microfluidic impedance flow cytometry has functioned as an enabling instrument in single-cell analysis, which, however, suffers from the limiting tradeoff between high sensitivity and clogging-free operation. In order to address this issue, this study presented a microfluidic impedance flow cytometer based on three-dimensional (3D) hydrodynamic focusing, in which the crossflow of conductive sample fluids and insulating sheath fluids was leveraged to centralize and restrict electric field lines to the sample fluid, thereby achieving high impedance sensitivity of single cells without the concern of channel blockage. Different from conventional impedance flow cytometry, in this study, impedance amplitude dips (rather than pulse singles) generated by single microparticles traveling through the 3D hydrodynamic focusing region were experimentally validated using microbeads.

View Article and Find Full Text PDF

Background: Ovarian cancer (OC) ranks among the most lethal gynecological malignancies. Research has highlighted long noncoding RNAs (lncRNAs) as promising novel molecular targets for cancer therapy. This study endeavors to identify novel lncRNAs, elucidate their specific roles, and unravel their regulatory mechanism in OC development.

View Article and Find Full Text PDF

Anemoside B4 improves cardiac function after myocardial infarction by regulating HTR2A/ERK pathway.

Int Immunopharmacol

August 2025

Department of Cardiology, Yantaishan Hospital, Yantai, Shandong 264000, China. Electronic address:

Purpose: Assessing the role of anemoside B4 (B4) in myocardial infarction (MI) and the regulatory mechanism was the purpose of this study.

Methods: We established MI rat model through ligation of the left anterior descending coronary artery and cardiomyocyte injury model through HO stimulation. The effects of B4 on cardiac function in MI rat model were assessed utilizing echocardiography, histological staining, and western blot.

View Article and Find Full Text PDF