Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Prcis: Increased oxygen saturation (StO 2 ) was significantly associated with the severity of visual field (VF) damage in patients with glaucoma.

Objective: To investigate the association between retinal StO 2 percentage and the severity of VF loss in glaucoma.

Methods: A total of 198 eyes from 131 patients with glaucoma were included in this cross-sectional study. Participants underwent imaging using ocular oximetry (Zilia) and 24-2 Swedish Interactive Threshold Algorithm standard VF (Carl Zeiss-Meditec). StO 2 (%) was measured at 2 locations of the peripapillary optic nerve head (superotemporal, and inferotemporal). Measurements were reported as the mean of at least 5 measurements in each location. Associations between the severity of VF loss, reported as mean deviation, and StO 2 (%) were calculated.

Results: A total of 198 eyes of 131 patients (mean (95% CI) age, 71.1 (68.9,73.3) years, 68 females (51.9%), and 63 males (48.1%) were analyzed. In univariable analysis, higher StO 2 -0.06 (-0.12, 0.00) was associated with severity in all hemifields ( P = 0.047). Multivariate regression analysis showed that each 1% increase in StO 2 was associated with -0.06 (-0.12, -0.00) dB loss in mean deviation in all hemifields ( P = 0.043). In multivariate regression analysis in the superior hemifields, higher StO 2 -0.07 (-0.16, 0.01) tended to be associated with superior hemifield severity ( P = 0.09).

Conclusions: Retinal oximetry enabled the continuous quantitative measurement of retinal StO 2. Increased StO 2 was significantly associated with the severity of VF damage in patients with glaucoma.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11412781PMC
http://dx.doi.org/10.1097/IJG.0000000000002481DOI Listing

Publication Analysis

Top Keywords

sto associated
12
associated severity
12
sto
9
oxygen saturation
8
severity visual
8
visual field
8
field damage
8
damage patients
8
retinal sto
8
severity loss
8

Similar Publications

For infection-associated implant osteomyelitis (IAOM) caused by Staphylococcus aureus, copper-induced bacterial death holds great potential. However, inducing bacterial cuproptosis-like death using low concentrations of copper (Cu) ions remains a challenge. Therefore, a "herbal-piezoelectric heterojunction" (Herbal-Piezo-HJ) is designed by integrating berberine (Ber) with Cu ion-doped Strontium titanate (SrTiO, STO) on a Ti substrate (STO-Cu@Ber).

View Article and Find Full Text PDF

Background And Objectives: Cerebrovascular pressure autoregulation (CAR) maintains adequate cerebral blood flow (CBF) despite changes in cerebral perfusion pressure. CAR is disrupted after cardiac arrest, making the brain vulnerable to inadequate perfusion and oxygen delivery at population-derived guideline-recommended blood pressures. A metric of CAR can be used to determine the mean arterial pressure (MAP) at which CAR is most preserved, termed the optimal MAP (MAP).

View Article and Find Full Text PDF

Hypoxemia, a common clinical phenomenon, is closely associated with various pathological conditions, including tumors and inflammatory diseases. The detection of tissue hypoxia holds significant potential for the detailed diagnosis of these conditions. Existing endoscopes, with the aid of probes, can perform point measurements of tissue oxygen saturation (), a well-established method for assessment.

View Article and Find Full Text PDF

Background: Cardiac surgery involving cardiopulmonary bypass (CPB) serves as a clinical model of ischemia-reperfusion injury and endothelial dysfunction. Endothelial injury is often manifested clinically by vasoplegia and microcirculatory disturbances. The administration of a single dose of corticosteroids at the time of anesthesia induction has been hypothesized to exert a protective effect.

View Article and Find Full Text PDF

Hyperspectral Imaging Accurately Detects Renal Malperfusion Due to High Intrarenal Pressure.

Eur Urol Open Sci

August 2025

Department of Urology and Urosurgery, Medical Faculty Mannheim, University Medical Center Mannheim, Heidelberg University, Heidelberg, Germany.

Background And Objective: High intrarenal pressure (IRP) is a significant concern in both endoscopic procedures and acute hydronephrosis, and may cause renal parenchymal damage, forniceal rupture, and long-term impaired renal function. Its pathomechanism and effect on renal perfusion patterns remain undetermined. This study investigates the impact of elevated IRP on renal perfusion and oxygen saturation (StO) using hyperspectral imaging (HSI).

View Article and Find Full Text PDF