Article Abstract

Background And Objectives: With the global population aging at an unprecedented pace, the imminent surge in falls and fall-induced injuries necessitates urgent attention. Innovative assistive technologies are crucial in addressing this daunting challenge. This study aimed to evaluate the mechanical properties, efficacy, safety, and user experience of the Intelligent Bone Protection Vest (IBPV), a novel, reusable, non-airbag wearable device.

Research Design And Methods: The IBPV integrates a machine learning-based algorithm for real-time monitoring of wearer motion and a unique honeycomb-structured foldable cushion for fall impact attenuation. We evaluated the impact attenuation capabilities of the IBPV and conducted 2 human subject studies to assess its efficacy and safety. Additionally, semistructured interviews were conducted to qualitatively explore its usability, safety, and opportunities for enhancement.

Results: The compression tests confirmed the energy absorption capacity of the honeycomb-structured foldable cushion. In over 800 fall tests involving 14 young and middle-aged subjects using a touchdown fall test, as well as 7 older subjects using a novel fall simulation test, the IBPV demonstrated an overall protection rate exceeding 84%.

Discussion And Implications: These results underscored the potential of the IBPV in reducing fall-induced injuries by mitigating the impact force on the hip during falls. Future studies with more rigorous design are needed to confirm whether this active wearable device may serve as a dependable fall protection product.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310589PMC
http://dx.doi.org/10.1093/geroni/igae066DOI Listing

Publication Analysis

Top Keywords

fall-induced injuries
12
user experience
8
wearable device
8
efficacy safety
8
honeycomb-structured foldable
8
foldable cushion
8
impact attenuation
8
ibpv
5
fall
5
mechanical property
4

Similar Publications

Ponticulus posticus (PP), also known as arcuate foramen, is an anatomical variation of the atlas (C1), which is an ossification of the posterior atlanto-occipital membrane and through which the V3 segment of the vertebral artery (VA) runs. Placement of a polyaxial screw in the C1 lateral mass is considered risky in those with PP because of possible risk for VA injury. We report a case with bilateral PP in which posterior fixation for unstable upper cervical spine injury was performed.

View Article and Find Full Text PDF

Performance of Natural Language Processing versus International Classification of Diseases Codes in Building Registries for Patients With Fall Injury: Retrospective Analysis.

JMIR Med Inform

July 2025

Foot & Ankle Research and Innovations Laboratory (FARIL), Department of Orthopaedic Surgery, Mass General Brigham, Harvard Medical School, 158 Boston Post Road, Weston, MA, 02493, United States, 1 7818279613.

Background: Standardized registries, such as the International Classification of Diseases (ICD) codes, are commonly built using administrative codes assigned to patient encounters. However, patients with fall injury are often coded using subsequent injury codes, such as hip fractures. This necessitates manual screening to ensure the accuracy of data registries.

View Article and Find Full Text PDF

Social vulnerability index enhances FRAX prediction of hip fractures in fall patients.

Sci Rep

April 2025

Department of Orthopaedic Surgery, Foot & Ankle Research and Innovation Lab (FARIL), Mass General Brigham, Harvard Medical School, Boston, MA, USA.

The Fracture Risk Assessment Tool (FRAX), widely used for predicting the 10-year likelihood of hip fractures, does not incorporate factors like prior falls and sociodemographic characteristics, notably the Social Vulnerability Index (SVI). Recognizing these limitations, we aim to evaluate the predictive accuracy of FRAX by integrating fall frequency, fall energy, and SVI into the model for assessing the risk of fall-induced hip fractures. A retrospective case-control study was conducted, and patients aged ≥ 40 years with a documented diagnosis of a fall-induced hip fracture were age-matched with controls with a history of falls without an associated hip fracture.

View Article and Find Full Text PDF

Background: Few studies have focused on comparing the effect of cognitive frailty (CF) with either cognitive impairment or frailty alone on fall risk. Further, studies investigating the effect of reversible cognitive frailty (RCF) or potentially reversible cognitive frailty (PRCF) on fall risk are scarce. This study aimed to investigate the influence of RCF and PRCF on falls in community-dwelling older adults of China and determine whether CF conferred a higher risk than cognitive impairment or frailty alone.

View Article and Find Full Text PDF

Biomechanical perspectives on image-based hip fracture risk assessment: advances and challenges.

Front Endocrinol (Lausanne)

May 2025

Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada.

Hip fractures pose a significant health challenge, particularly in aging populations, leading to substantial morbidity and economic burden. Most hip fractures result from a combination of osteoporosis and falls. Accurate assessment of hip fracture risk is essential for identifying high-risk individuals and implementing effective preventive strategies.

View Article and Find Full Text PDF