98%
921
2 minutes
20
Photon counting CT was recently introduced into clinical practice [Rajendran K, Petersilka M, Henning A, Shanblatt ER, Schmidt B, Flohr TG, Ferrero A, Baffour F, Diehn FE, Yu L, Rajiah P, Fletcher JG, Leng S, McCollough CH. First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology 2022;303(1):130-138. doi: https://doi.org/10.1148/radiol.212579 ]. Photon counting detectors (PCD) afford better spatial resolution, radiation dose efficiency, and iodine contrast-to-noise than EID-CT [Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, Fletcher JG, McCollough CH. Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. Radiographics 2019;39(3):729-743. doi: https://doi.org/10.1148/rg.2019180115 ); (Leng S, Rajendran K, Gong H, Zhou W, Halaweish AF, Henning A, Kappler S, Baer M, Fletcher JG, McCollough CH. 150-mum Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images. Invest Radiol 2018;53(11):655-662. doi: https://doi.org/10.1097/RLI.0000000000000488 )(Booij R, van der Werf NR, Dijkshoorn ML, van der Lugt A, van Straten M. Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data. Diagnostics (Basel) 2022;12(6). doi: https://doi.org/10.3390/diagnostics12061467 ); (Sawall S, Klein L, Amato C, Wehrse E, Dorn S, Maier J, Heinze S, Schlemmer HP, Ziener CH, Uhrig M, Kachelriess M. Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol 2020;126:108909. doi: https://doi.org/10.1016/j.ejrad.2020.108909 ] while also maintaining multienergy CT (MECT) capabilities[Flohr T, Petersilka M, Henning A, Ulzheimer S, Ferda J, Schmidt B. Photon-counting CT review. Phys Med 2020;79:126-136. doi: https://doi.org/10.1016/j.ejmp.2020.10.030 ]. This article will review the clinical adoption of PCD-CT including protocol development, clinical applications, clinical integration and workflow considerations. Protocol development is institution specific and involves collaborative decision-making among radiologists, physicists, and technologists. Key PCD clinical applications include radiation exposure reduction, intravenous contrast volume reduction, and improved lesion conspicuity. Patients who would most benefit from these improvements may preferentially be scanned with PCD CT. With numerous available reconstructions, radiologists should be strategic in the series sent to PACS for interpretation and routinely sending spectral series to PACS can facilitate integration with clinical workflow. The Society of Abdominal Radiology PCD Emerging Technology Commission endorsed this article.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00261-024-04503-5 | DOI Listing |
Comput Methods Programs Biomed
September 2025
Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, Nanjing, 210096, China; Jiangsu Provincial Joint International Research Laboratory of Medical Information Processing, Southeast University, Nanjing, 210096, China. Electronic address: xuji@s
Background: Photon counting computed tomography (PCCT) has emerged as a potential technology that is revolutionizing clinical CT imaging. Using photon counting detectors (PCDs), the PCCT counts each X-ray event and measures the corresponding energy above the noise floor with significantly higher spatial resolution. However, the multiple-energy-bin setting and much smaller pixels increase the raw data size of PCCT by 20-100 times compared to traditional CT.
View Article and Find Full Text PDFACS Nano
September 2025
School of Physics and Key Lab of Quantum Materials and Devices of the Ministry of Education, Southeast University, Nanjing 211189, P. R. China.
While hexagonal boron nitride (hBN) hosts promising room-temperature quantum emitters for hybrid quantum photonic circuits, scalable deterministic integration and insufficient brightness alongside low photon collection and coupling efficiencies remain unresolved challenges. We present a femtosecond laser nanoengineering platform that enables the site-specific generation of hBN single-photon source (SPS) arrays. First-principles density functional theory (DFT) calculations and polarization-resolved spectroscopy confirm the atomic origin of emission as interfacial defects at hBN/SiO heterojunctions.
View Article and Find Full Text PDFAJR Am J Roentgenol
September 2025
Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China.
Patients with inflammation-associated coronary artery disease (CAD) may exhibit rapid progression and require regular coronary imaging. To evaluate the diagnostic performance of spectral photon-counting detector (PCD) coronary CTA with reduced radiation and contrast media doses for detecting coronary stenosis and in-stent restenosis in patients with inflammation-associated CAD. This prospective study enrolled patients with inflammation-associated CAD from January 2023 to March 2024.
View Article and Find Full Text PDFRadiol Phys Technol
September 2025
Department of Cardiovascular Internal Medicine, NHO Kagoshima Medical Center, 8-1, Shiroyamacho, Kagoshima, Kagoshima, 892-0853, Japan.
In Tl myocardial perfusion single-photon emission computed tomography (SPECT), gastric wall uptake can impact the inferior wall. This study aimed to evaluate the effectiveness and usefulness of the masking on un-smoothed image (MUS) method for Tl myocardial perfusion SPECT. A hemispherical gastric wall phantom was created to simulate the gastric fundus located closest to the myocardium, and the activity was enclosed to achieve an SPECT count ratio against the myocardium equivalent to that observed in clinical practice.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
September 2025
From the Department of Otorhinolaryngology Head and Neck Surgery (J.G., Y.L., S.G.) and Department of Radiology (N.X., R.T., H.D.,Z.Y., Z.W., P.Z.), Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Background And Purpose: Isolated congenital middle ear malformation contributes significantly to congenital hearing loss and growth problems. This study aims to compare 0.1 mm isotropic ultra-high-resolution computed tomography and conventional high-resolution computed tomography for assessing isolated congenital middle ear malformation, using surgical exploration as the gold standard.
View Article and Find Full Text PDF