98%
921
2 minutes
20
The occurrence of microplastics in aquatic environments has attracted increasing interest from both the public and scientists, especially their migration behaviors. Although several environmental behaviors of microplastics have been studied, the issue of microplastic suspension and deposition in lake sediment-water systems remains to be elucidated. In this study, we built an indoor sediment-water system with input and output rivers that simulated the actual situations in lakes, and aimed to explore the suspension and deposition behavior of microplastics using eight group experiments. The abundance of microplastics in overlying water and sediments in different periods was analyzed, and the characteristics of hydrodynamic disturbance on microplastic suspension and deposition were identified. Importantly, the exchange of microplastics in sediments and water under dynamic flow conditions was assessed. The results showed that the middle-scale experiment designed in this study effectively simulated the dynamic transport process of microplastics in lakes, and the hydrodynamic force had a significant impact on the suspension and deposition behaviors of microplastics. The average abundance of polystyrene, polyethylene terephthalate and polyamide microplastics was 1.07, 0.60 and 0.83 particles/L in overlying water during the suspension experiments, respectively. This showed a pattern of first rising and then falling with the extension of suspension time. Even in the environment with the maximum input water volume (8000 ml/min) in this study, only microplastics at a depth of 0 to 2 cm from the sediment were suspended. The average abundance of microplastics was 313.02 particles/kg during the deposition experiments, which gradually increased with the extension of deposition time in sediments. Finally, microplastic sizes in water of the suspension experiments and in sediments of the deposition experiments were concentrated in the range of 500 to 1500 μm and 300 to 1000 μm, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11356-024-33743-7 | DOI Listing |
Carbohydr Polym
November 2025
Department of Chemical Science and Technologies, University of Tor Vergata, Via della Ricerca Scientifica, 000133 Rome, Italy. Electronic address:
Two forms of nanocellulose-based sensing materials were developed for heavy metal ions (HMIs) detection: all-solid-state and suspension. In these materials, cellulose nanofibers (CNF), isolated from cellulose bleached pulp via homogenization, were employed as a support matrix. For all-solid-state optodes development free-base 5,10,15,20-tetraphenylporphyrin (TPP) and zinc-porphyrin derivative (ZnPC) were deposited on CNF support.
View Article and Find Full Text PDFTissue Eng Part A
September 2025
Department of Orthopaedic Surgery, McKay Orthopaedic Research Laboratory, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Cell and tissue engineering therapies provide promise for regenerating damaged intervertebral disc (IVD) tissue and resolving the low back pain that often accompanies it. However, these treatments remain experimental and unavailable for patients. Furthermore, the large body of work characterizing and utilizing mesenchymal stromal cells (MSCs) for these applications has, unfortunately, not resulted in any FDA-approved spinal therapies.
View Article and Find Full Text PDFSci Rep
September 2025
Department of Therapeutic Chemistry, National Research Centre, 33 El-Bohouth St., Dokki, Cairo, 12622, Egypt.
Gouty arthritis (GA) is an inflammatory arthritic disorder that is characterized by intense, acute inflammatory responses, such as synovitis and arthritis that occur due to articular deposition of monosodium urate (MSU) crystals. This study has compared the therapeutic potentials of either Berberine (BERB) or Paracetamol (Para) on MSU-induced inflammation in rat model of Gouty arthritis (GA). GA was induced by "intra-articular" injection of MSU suspension (20 mg/ml) inside the knee joint of the rat's right limb.
View Article and Find Full Text PDFCells
August 2025
Division of Transplant Immunology, Department of Pathology and Laboratory Medicine, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
Appropriate concentrations of reagents, an absence of significant cell clumps and debris, minimization of artifacts and ensuring satisfactory cell preservation directly affect the quality of data generated and cannot be overestimated. Traditionally, cells in suspension are prepared using a cytospin, which uses centrifugal force to concentrate and deposit cells onto a glass slide. Adherent cells are traditionally grown on coverslips located on the bottom of the wells of cell culture plates, or using special chamber slide systems.
View Article and Find Full Text PDFPalaeontology
November 2024
Bristol Palaeobiology Group, School of Earth Sciences, University of Bristol, Life Sciences Building, Tyndall Avenue, Bristol BS8 1TQ, UK.
Early vertebrate evolution has been characterized as a gradual shift from passive to more active feeding modes. However, this evolutionary scenario is contingent on poorly constrained inferences of the feeding ecology of extinct stem-gnathostomes. Heterostracans are among the earliest members of the gnathostome stem-lineage.
View Article and Find Full Text PDF