Article Abstract

The use of photon counting detectors in X-ray imaging missions can effectively improve the signal-to-noise ratio and image resolution. However, the stitching of photon counting detector modules leads to large-size localized information loss in the acquired projected image, which seriously affects the regional observation. In this paper, we propose a method to fill the inter-module gap based on dual acquisition, referred to as the GFDA algorithm, which is divided into three main steps: (i) acquire the main projection by short-exposure scanning, and then scan again by vertically moving the carrier table to acquire the reference projection; (ii) use the alignment method to locate the projected region of interest; (iii) use image stitching and image fusion to recover the missing information. We analyzed the gray value of the region of interest of the Siemens star projection and the reconstructed conch slice data, and proved that the proposed method can recover the information more smoothly and perfectly. The GFDA algorithm is able to achieve a better image restoration effect without additional scanning time and better retain image details. In addition, the GFDA algorithm is scalable, which is demonstrated in the task of filling the stitching of multiple types of photonic technology detectors.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.508066DOI Listing

Publication Analysis

Top Keywords

photon counting
12
gfda algorithm
12
inter-module gap
8
counting detectors
8
based dual
8
dual acquisition
8
region interest
8
image
6
gap filling
4
method
4

Similar Publications

Evaluation of the usefulness of the masking on un-smoothed image method in Tl myocardial perfusion SPECT.

Radiol Phys Technol

September 2025

Department of Cardiovascular Internal Medicine, NHO Kagoshima Medical Center, 8-1, Shiroyamacho, Kagoshima, Kagoshima, 892-0853, Japan.

In Tl myocardial perfusion single-photon emission computed tomography (SPECT), gastric wall uptake can impact the inferior wall. This study aimed to evaluate the effectiveness and usefulness of the masking on un-smoothed image (MUS) method for Tl myocardial perfusion SPECT. A hemispherical gastric wall phantom was created to simulate the gastric fundus located closest to the myocardium, and the activity was enclosed to achieve an SPECT count ratio against the myocardium equivalent to that observed in clinical practice.

View Article and Find Full Text PDF

Isolated Congenital Middle Ear Malformations: Comparison of preoperative 0.1 mm Ultra-High-Resolution CT and Conventional High-Resolution CT.

AJNR Am J Neuroradiol

September 2025

From the Department of Otorhinolaryngology Head and Neck Surgery (J.G., Y.L., S.G.) and Department of Radiology (N.X., R.T., H.D.,Z.Y., Z.W., P.Z.), Beijing Friendship Hospital, Capital Medical University, Beijing, China.

Background And Purpose: Isolated congenital middle ear malformation contributes significantly to congenital hearing loss and growth problems. This study aims to compare 0.1 mm isotropic ultra-high-resolution computed tomography and conventional high-resolution computed tomography for assessing isolated congenital middle ear malformation, using surgical exploration as the gold standard.

View Article and Find Full Text PDF

In Thailand, sexually transmitted infections (STIs) persist as a significant public health issue, notwithstanding the affordability of treatments. The primary challenge lies in diagnostic methodologies. According to the Thai National Treatment Guidelines for abnormal vaginal discharge, wet preparation using proportion of white blood cell (WBC) counts and epithelial cell (EC) guides presumptive STI treatment.

View Article and Find Full Text PDF

PurposeTo evaluate the potential of Photon-Counting Detector CT Angiography (PCD-CTA) for the assessment of carotid and subclavian artery stents compared to digital subtraction angiography (DSA) and Duplex ultrasound (DUS).MethodsThis study is a single-center, retrospective analysis of consecutive patients treated with a stent for high grade stenosis of the extra-cranial carotid and the subclavian artery between April 2023 and May 2024. Polyenergetic images (PE), iodine and virtual monoenergetic images were performed at different keV levels (40 and 80) and with two body vascular reconstruction kernels (Bv56 and 72) with and without iterative metal artifact reduction.

View Article and Find Full Text PDF

Drug delivery to the central nervous system (CNS) is primarily hindered by the blood-brain barrier (BBB). To address this, mucoadhesive formulations have been designed to prolong residence time at the application site. In this study, we comprehensively characterized the physicochemical and mucoadhesive properties of hyaluronic acid tyramine (HATA) photocrosslinked hydrogels using rheological methods, nanoindentation, contact angle goniometry, and advanced confocal microscopy.

View Article and Find Full Text PDF