Multifaceted experiments and photothermal simulations based analysis of laser induced graphene and its fibers.

Discov Nano

Chair Measurement and Sensor Technology, Department of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09107, Chemnitz, Germany.

Published: March 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The interaction of CO laser with polyimide results in the formation of laser-induced graphene (LIG) and other morphological transitions based on laser parameters, such as Laser-induced fibers (LIF) on the surface. However, a fundamental investigation of LIF, its properties and potential have not been explored until now. We aim therefore to provide novel insights into the LIF by characterization of its structural, electrical, electrochemical, and mechanical properties. Four different morphologies were identified depending on the laser parameters and the temperature required for their formation were quantified by FEM model. Minimum temperatures of 1800 K were required to form LIG and around 2600 to 5000 K to form LIF. High heterogeneity of the LIF along thickness due to temperature gradients, and the existence of sheet structures underneath the fibers were identified. Due to the loosely bound nature of fibers, LIF dispersion was prepared by ultrasonication to functionalize the carbon electrode for electrochemical characterization. The modification with LIF on the electrodes enhanced the electrochemical response of the electrode towards standard redox couple which confirmed the conductive nature of the fibers. This work provides a solid basis for the versatile tuning of the behavior and properties of LIF for potential applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10978564PMC
http://dx.doi.org/10.1186/s11671-024-03999-6DOI Listing

Publication Analysis

Top Keywords

laser parameters
8
lif
8
fibers lif
8
nature fibers
8
fibers
5
multifaceted experiments
4
experiments photothermal
4
photothermal simulations
4
simulations based
4
based analysis
4

Similar Publications

Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.

View Article and Find Full Text PDF

Drought stress affects plant growth and production. To cope with drought stress, plants induced physiological and metabolic changes, serving as a protective approach under drought-stress conditions. The response to drought can vary based on plant type (C3 vs.

View Article and Find Full Text PDF

In vitro assessment of the inhibitory effect of antiplatelet drugs on platelet aggregation is frequently employed to guide personalized antiplatelet therapy in clinical practice. However, existing methods for detecting platelet aggregation rely heavily on high concentrations of exogenous agonists, which may obscure part of the inhibitory effect of antiplatelet drugs and lead to an underestimation of their effects. This study validates a novel analytical strategy for evaluating the effects of antiplatelet drugs by quantifying the microscopic three-dimensional morphological parameters of platelet aggregates formed through spontaneous aggregation on a glass surface.

View Article and Find Full Text PDF

Differences in the Corneal Biomechanical Responses to LASIK and KLEx Based on Parametric Numerical Simulation.

J Refract Surg

September 2025

From National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.

Purpose: To use parametric numerical simulation to characterize and compare the differences in corneal biomechanical responses to laser in situ keratomileusis (LASIK) and keratorefractive lenticule extraction (KLEx) under various surgical settings.

Methods: The Finite Element Model was used in a parametric study to evaluate corneal biomechanical responses to LASIK and KLEx, considering variations in preoperative corneal thickness, corneal flap/cap thickness and diameter, refractive correction, and optical zone diameter. Surgery-induced stress, displacement, and interface contact pressure were compared between LASIK and KLEx using the Wilcoxon signed-rank test.

View Article and Find Full Text PDF

Purpose: To determine the accuracy of a new machine learning-based open-source IOL formula (PEARLS-DGS) in 100 patients who underwent uncomplicated cataract surgery and had a history of laser refractive surgery for myopic defects.

Methods: The setting for this retrospective study was HUMANITAS Research Hospital, Milan, Italy. Data from 100 patients with a history of photorefractive keratectomy or laser in situ keratomileusis were retrospectively analyzed to assess the accuracy of the formula.

View Article and Find Full Text PDF