Biomechanical assessment of different transforaminal lumbar interbody fusion constructs in normal and osteoporotic condition: a finite element analysis.

Spine J

Department of Orthopedics, Qilu Hospital of Shandong University, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, 250012, P.R. China; Department of Orthopedics, Qilu Hospital of Shandong University(Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, Shandong, 26603

Published: June 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background Context: With the aging population, osteoporosis, which leads to poor fusion, has become a common challenge for lumbar surgery. In addition, most people with osteoporosis are elderly individuals with poor surgical tolerance, and poor bone quality can also weaken the stability of internal fixation.

Purpose: This study compared the fixation strength of the bilateral traditional trajectory screw structure (TT-TT), the bilateral cortical bone trajectory screw structure (CBT-CBT), and the hybrid CBT-TT (CBT screws at the cranial level and TT screws at the caudal level) structure under different bone mineral density conditions.

Study Design: A finite element (FE) analysis study.

Methods: Above all, we established a healthy adult lumbar spine model. Second, under normal and osteoporotic conditions, three transforaminal lumbar interbody fusion (TLIF) models were established: bilateral traditional trajectory (TT-TT) screw fixation, bilateral cortical bone trajectory (CBT-CBT) screw fixation, and hybrid cortical bone trajectory screw and traditional trajectory screw (CBT-TT) fixation. Finally, a 500-N compression load with a torque of 10 N/m was applied to simulate flexion, extension, lateral bending, and axial rotation. We compared the range of motion (ROM), adjacent disc stress, cage stress, and posterior fixation stress of the different fusion models.

Results: Under different bone mineral density conditions, the range of motion of the fusion segment was significantly reduced. Compared to normal bone conditions, the ROM of the L4-L5 segment, the stress of the adjacent intervertebral disc, the surface stress of the cage, and the maximum stress of the posterior fixation system were all increased in osteoporosis. Under most loads, the ROM and surface stress of the cage and the maximum stress of the posterior fixation system of the TT-TT structure are the lowest under normal bone mineral density conditions. However, under osteoporotic conditions, the fixation strength of the CBT-CBT and CBT-TT structures are higher than that of the TT-TT structures under certain load conditions. At the same time, the surface stress of the intervertebral fusion cage and the maximum stress of the posterior fixation system for the two structures are lower than those of the TT-TT structure.

Conclusion: Under normal bone mineral density conditions, transforaminal lumbar interbody fusion combined with TT-TT fixation provides the best biomechanictability. However, under osteoporotic conditions, CBT-CBT and CBT-TT structures have higher fixed strength compared to TT-TT structures. The hybrid CBT-TT structure exhibits advantages in minimal trauma and fixation strength. Therefore, this seems to be an alternative fixation method for patients with osteoporosis and degenerative spinal diseases.

Clinical Significance: This study provides biomechanical support for the clinical application of hybrid CBT-TT structure for osteoporotic patients undergoing TLIF surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2024.01.017DOI Listing

Publication Analysis

Top Keywords

trajectory screw
16
bone mineral
16
mineral density
16
stress posterior
16
posterior fixation
16
transforaminal lumbar
12
lumbar interbody
12
interbody fusion
12
fixation
12
fixation strength
12

Similar Publications

Computer-assisted surgery and planning in percutaneous pelvic screw fixation.

Orthop Traumatol Surg Res

September 2025

CHU de Grenoble-Alpes, Université de Grenoble-Alpes, Laboratoire TIMC-IMAG, Unité de Chirurgie Orthopédique et Traumatologique, CNRS UMR 5525, Boulevard de la Chantourne, 38700 La Tronche, France.

Percutaneous pelvic screwing (PPS) enables fixation of traumatic or atraumatic fractures with little or no displacement, or displaced but reduced fractures, and preventive fixation of primary or secondary tumoral lesions. It is a relatively recent technique, and indications are evolving with progress in pre- and intra-operative imaging. Morbidity is lower than with open surgery.

View Article and Find Full Text PDF

Objective: To determine if a novel robotic system has comparable positional and angular accuracy to that achievable with patient-specific guides (PSG) when used for transcondylar screw (TCS) placement in the canine humerus.

Study Design: Experimental laboratory study.

Sample Population: A total of 32 synthetic humeral models (16 per group).

View Article and Find Full Text PDF

Background: Screw fixation is pivotal for prosthetic stability. For 3D-printed customized acetabular revision prostheses designed for complex, large-scale bone defects, precise adherence to preoperative screw trajectory planning is critical. However, there remains a lack of standardized three-dimensional (3D) evaluation protocols to quantify intraoperative screw angular alignment fidelity relative to preoperative digital plans, hindering universal validation criteria.

View Article and Find Full Text PDF

Radiographic parameters and feasibility analysis of dual sacral-2 alar-iliac screw fixation using three-dimensional digital technology.

BMC Musculoskelet Disord

September 2025

Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefangnan Road, Hexi District, Tianjin, China.

Objective: The purpose of this study was to evaluate the feasibility and the trajectories of dual sacral-2 alar-iliac (S2AI) screw fixation with three-dimensional digital technology simulation analysis.

Methods: The pelvic computed tomography scan data of 60 (30 men and 30 women, age: 25-86 years) individuals were selected and reconstructed. The trajectories of dual S2AI screws were plotted using three-dimensional reconstruction software.

View Article and Find Full Text PDF

Objective: We aim to identify the characteristics and risk factors of intravascular cement leakage (CL) in cement-augmented fenestrated pedicle screw (CAFPS) insertion, particularly focusing on screw trajectory, bone density, and vertebral body volume.

Methods: A retrospective observational study was conducted on 41 patients who underwent spinal fixation surgery with CAFPS from June 2022 to November 2024. Intravascular cement leakage (CL) was assessed using postoperative computed tomography (CT) scans.

View Article and Find Full Text PDF