Article Abstract

Background And Objective: We aimed to investigate long-term clinical and echocardiographic outcomes, including tricuspid valve durability, annular growth, and left ventricular reverse remodeling, after modified cone reconstruction in patients with Ebstein's anomaly.

Methods: This was a retrospective analysis of all pediatric patients who underwent modified cone reconstruction for Ebstein's anomaly at a single tertiary center between January 2005 and June 2021.

Results: A total of 14 pediatric patients underwent modified cone reconstruction for Ebstein's anomaly; the median age was 5.8 years (range, 0.01-16.6). There were three patients (21.4%) with Carpentier type B, ten patients with Carpentier type C (71.4%), and one patient with Carpentier type D (7.1%). There was no early or late mortality, arrhythmia, or readmission for heart failure at a 10-year follow-up. There were no cases of more than mild tricuspid stenosis or more than moderate tricuspid regurgitation during the study period, except for one patient with severe tricuspid regurgitation who underwent reoperation. The z value for tricuspid valve annular size significantly decreased immediately after the operation (2.46 vs. -1.15, p<0.001). However, from 1 year to 7 years after surgery, the z values were maintained between -1 and +1. Left ventricular end-systolic volume, end-diastolic volume, and stroke volume increased after surgery and remained elevated until seven years postoperatively.

Conclusions: Ebstein's anomaly in children can be repaired by modified cone reconstruction with low mortality and morbidity, good tricuspid valve durability, and annular growth relative to somatic growth.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10864249PMC
http://dx.doi.org/10.4070/kcj.2023.0200DOI Listing

Publication Analysis

Top Keywords

modified cone
16
cone reconstruction
16
reconstruction ebstein's
12
ebstein's anomaly
12
pediatric patients
12
carpentier type
12
tricuspid valve
8
patients underwent
8
underwent modified
8
tricuspid regurgitation
8

Similar Publications

Fast Scan Cyclic Voltammetry (FSCV) is a widely used electrochemical technique to detect rapid extracellular dopamine transients . It employs carbon fiber microelectrodes (CFMEs), but conventional 7 µm diameter CFMEs often suffer from limited mechanical durability and reduced lifespan, hindering their use in chronic monitoring. To improve mechanical robustness and long-term functionality, we fabricated 30 µm diameter CFMEs and modified their geometry via electrochemical etching to form cone-shaped tips.

View Article and Find Full Text PDF

Phytic acid and melamine-modified microcrystalline cellulose as effective flame retardants in polylactic acid composites.

Carbohydr Polym

November 2025

School of Chemistry and Chemical Engineering, State Key Laboratory Incubation Base for Green Processing of Chemical Engineering, Shihezi University, Shihezi, Xinjiang 832003, China. Electronic address:

This study introduces a novel bio-based flame retardant, MCC-GMA-PA-MEL, synthesized from microcrystalline cellulose (MCC) modified with phytic acid (PA) and melamine (MEL). Characterization of the resulting composites revealed a significant enhancement in PLA crystallinity to 35.9 %, driven by improved molecular mobility and heterogeneous nucleation effects.

View Article and Find Full Text PDF

The use of highly flammable materials such as foams, resins, and plastics has led to an increase in the frequency and severity of urban fires worldwide. To address this issue, this study developed a high-specific-surface-area mesoporous metal-organic framework (Fe-MOFs) with heat trapping and smoke adsorption. The Fe-MOFs, zinc tailings (ZTs), piperazine pyrophosphate (PAPP), and sodium lignosulfonate (LS) were used to modify rigid polyurethane foam (RPUF).

View Article and Find Full Text PDF

An open-source irradiation and data-handling framework for pre-clinical ion-beam research.

Z Med Phys

September 2025

Division of Medical Physics, Department of Radiation Oncology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria; MedAustron Ion Therapy Center, Marie Curie-Straße 5, A-2700 Wiener Neustadt, Austria.

Context: Pre-clinical animal studies are pivotal for understanding the radiation effects in particle therapy. However, small animal research often relies on highly customized in-house solutions. This study introduces a comprehensive, open-source data processing pipeline specifically developed for pre-clinical particle irradiation research in a multi-vendor setting.

View Article and Find Full Text PDF

Bentonite materials are extensively used in cutoff walls at landfill sites. This study calculates the stress and permeability characteristics of bentonite materials using the piezocone penetration test (CPTU) and ABAQUS simulations. The lateral effective stress of bentonite materials is evaluated using arching models, lateral squeezing models, and a modified lateral squeezing model.

View Article and Find Full Text PDF