Objectives: Both contrast-enhanced ultrasound (CEUS) and contrast-enhanced magnetic resonance (CEMR) are important imaging methods for hepatocellular carcinoma (HCC). This study aimed to establish a model using preoperative CEUS parameters to predict microvascular invasion (MVI) in HCC, and compare its predictive efficiency with that of CEMR model.

Methods: A total of 93 patients with HCC (39 cases in MVI positive group and 54 cases in MVI negative group) who underwent surgery in our hospital from January 2020 to June 2021 were retrospectively analyzed. Their clinical and imaging data were collected to establish CEUS and CEMR models for predicting MVI. The predictive efficiencies of both models were compared.

Results: By the univariate and multivariate regression analyses of patients' clinical information, preoperative CEUS static and dynamic images, we found that serrated edge and time to peak were independent predictors of MVI. The CEUS prediction model achieved a sensitivity of 92.3%, a specificity of 83.3%, and an accuracy of 84.6% (Az: 0.934). By analyzing the clinical and CEMR information, we found that tumor morphology, fast-in and fast-out, peritumoral enhancement, and capsule were independent predictors of MVI. The CEMR prediction model achieved a sensitivity of 97.4%, a specificity of 77.8%, and an accuracy of 83.2% (Az: 0.900). The combination of the two models achieved a sensitivity of 84.6%, a specificity of 87.0%, and an accuracy of 86.2% (Az: 0.884). There was no significant statistical difference in the areas under the ROC curve of the three models.

Conclusion: The CEUS model and the CEMR model have similar predictive efficiencies for MVI of HCC. CEUS is also an effective method to predict MVI before operation.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jum.16375DOI Listing

Publication Analysis

Top Keywords

achieved sensitivity
12
contrast-enhanced ultrasound
8
microvascular invasion
8
hepatocellular carcinoma
8
preoperative ceus
8
mvi
8
mvi hcc
8
cases mvi
8
predictive efficiencies
8
independent predictors
8

Similar Publications

Viscosity-sensitive fluorescent probes based on the hemicyanine for the organelle-specific visualization during autophagy and ferroptosis.

Spectrochim Acta A Mol Biomol Spectrosc

September 2025

College of Chemistry, Chemical Engineering and Material Science, Soochow University, No. 199 Ren'Ai Road, Suzhou 215123, China; Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou 215163, China. Electronic address: g

The dynamic monitoring of cell death processes remains a significant challenge due to the scarcity of highly sensitive molecular tools. In this study, two hemicyanine-based probes (5a-5b) with D-π-A structures were developed for organelle-specific viscosity monitoring. Both probes exhibited correlation with the Förster-Hoffmann viscosity-dependent relationship (R > 0.

View Article and Find Full Text PDF

Programmable Dual-Phase Electrochemical Biosensor Combines Homogeneous CRISPR/Cas12a Activation with Interfacial Poly-G Signaling for miRNA-21 Detection.

Anal Chem

September 2025

Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological and Chemical Engineering, Jiaxing University, Jiaxing 314001, China.

Despite the promise of electrochemical biosensors in amplified nucleic acid diagnostics, existing high-sensitivity platforms often rely on a multilayer surface assembly and cascade amplification confined to the electrode interface. These stepwise strategies suffer from inefficient enzyme activity, poor mass transport, and inconsistent probe orientation, which compromise the amplification efficiency, reproducibility, and practical applicability. To address these limitations, we report a programmable dual-phase electrochemical biosensing system that decouples amplification from signal transduction.

View Article and Find Full Text PDF

In charge detection mass spectrometry (CD-MS) ions are trapped in an electrostatic linear ion trap (ELIT) where they oscillate back and forth through a conducting cylinder. The oscillating ions induce a periodic charge separation that is detected by a charge sensitive amplifier (CSA) connected to the cylinder. The resulting time domain signal is analyzed using short-time Fourier transforms to give the mass-to-charge ratio and charge for each ion, which are then multiplied to give the mass.

View Article and Find Full Text PDF

Purpose: To evaluate inter-grader variability in posterior vitreous detachment (PVD) classification in patients with epiretinal membrane (ERM) and macular hole (MH) on spectral-domain optical coherence tomography (SD-OCT) and identify challenges in defining a reliable ground truth for artificial intelligence (AI)-based tools.

Methods: A total of 437 horizontal SD-OCT B-scans were retrospectively selected and independently annotated by six experienced ophthalmologists adopting four categories: 'full PVD', 'partial PVD', 'no PVD', and 'ungradable'. Inter-grader agreement was assessed using pairwise Cohen's kappa scores.

View Article and Find Full Text PDF

Background: Severe acute pancreatitis (SAP) is a life-threatening condition requiring early risk stratification. While the Bedside Index for Severity in Acute Pancreatitis (BISAP) is widely used, its reliance on complex parameters limits its applicability in resource-constrained settings. This study introduces a decision tree model based on Classification and Regression Tree (CART) analysis, utilizing Neutrophil-to-Lymphocyte Ratio (NLR) and C-reactive Protein (CRP), as a simpler alternative for early SAP prediction.

View Article and Find Full Text PDF