Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Previously, radioimmunoassay (RIA) has been the only assay to measure insulin-like growth factor-1 (IGF-1) to diagnose hypersomatotropism (HS). Due to radiation concerns, availability, and the cost of IGF-1 RIA, validation of assays for automated analysers such as a chemiluminescent immunoassay (CLIA) is needed. The aim of this study was to validate a CLIA for measurement of feline IGF-1 (IMMULITE 2000 XPi, Siemens Medical Solutions Diagnostics, Malvern, PA, USA) compared to IGF1 RIA, establish reference interval (RI), and determine a cut-off value for diagnosis of HS in diabetic cats. Validation of assay performance included precision, linearity, and recovery studies. Right-sided RI was determined using surplus serum of 50 healthy adult cats. Surplus serum samples of diabetic cats with known IGF-1 concentration with ( = 32/68) and without HS ( = 36/68) were used for method comparison with RIA. The cut-off for diagnosis of HS was established using receiver operating characteristic (ROC) analysis. The intra-assay coefficient of variation (CV) was ≤4.7%, and the inter-assay CV was ≤5.6% for samples with low, medium, and high IGF-1 concentration. Linearity was excellent (R > 0.99). The correlation between CLIA and RIA was very high (r = 0.97), with a mean negative bias for CLIA of 24.5%. The upper limit of RI was 670 ng/mL. ROC analysis showed an area under the curve of 0.94, with best cut-off for diagnosis of HS at 746 ng/mL (sensitivity, 84.4%; specificity, 97.2%). The performance of CLIA was good, and the RI and cut-off for HS diagnosis established in this study allow for CLIA to be used in routine work-up of diabetic cats.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10534906PMC
http://dx.doi.org/10.3390/vetsci10090575DOI Listing

Publication Analysis

Top Keywords

cut-off diagnosis
16
diabetic cats
12
insulin-like growth
8
growth factor-1
8
chemiluminescent immunoassay
8
surplus serum
8
igf-1 concentration
8
diagnosis established
8
roc analysis
8
clia
6

Similar Publications

Introduction: A no-biopsy approach has been suggested for diagnosing coeliac disease (CD) in adult patients. This approach is already well established in diagnosing children with CD. This study aimed to evaluate the accuracy of IgA anti-tissue transglutaminase (IgA anti-tTG) in predicting duodenal mucosal lesions diagnostic of CD in adult patients.

View Article and Find Full Text PDF

Objectives: Lymph node metastasis (LNM) is an important factor affecting the stage and prognosis of patients with lung adenocarcinoma. The purpose of this study is to explore the predictive value of the stacking ensemble learning model based on F-FDG PET/CT radiomic features and clinical risk factors for LNM in lung adenocarcinoma, and elucidate the biological basis of predictive features through pathological analysis.

Methods: Ninety patients diagnosed with lung adenocarcinoma who underwent PET/CT were retrospectively analyzed and randomly divided into the training and testing sets in a 7:3 ratio.

View Article and Find Full Text PDF

Purpose: This research aimed to investigate the association between neutrophil-percentage-to-albumin ratio (NPAR), systemic immune-inflammation index (SII), systemic inflammation response index (SIRI), and aggregate index of systemic inflammation (AISI) with disease severity in patients diagnosed with acute myocarditis.

Methods: A total of 185 patients were diagnosed with acute myocarditis at the First Hospital of Jilin University between 2018 and 2024. The related values of NPAR, SII, SIRI, and AISI were computed based on the pertinent blood indices that were acquired within 12 hours of admission.

View Article and Find Full Text PDF

Objectives: To evaluate whether q-Dixon sequence-based fat fraction (FF) values of the lumbar spine can predict osteoporotic vertebral compression fracture (OVCF) risk in older adult(s) osteoporosis patients.

Materials & Methods: Thirty OVCF patients and 15 osteoporosis patients were enrolled. Areas of interest (ROIs) were manually drawn using the post-processing workstation, and FF values of the patient's L1-L4 vertebrae (except the fractured vertebrae) were measured.

View Article and Find Full Text PDF

Background Increased intracranial pressure (ICP) can be reliably detected at the bedside using the optic nerve sheath diameter (ONSD). The functional outcome in stroke patients can be predicted with the use of acute-phase ONSD dynamics. Objectives To determine the predictive accuracy of ONSD on days 0, one, and three for the prognosis of ischemic stroke patients presented to emergency medicine as measured by Modified Rankin Scale (mRS) score.

View Article and Find Full Text PDF