Article Abstract

Purpose: Developing a general framework with a novel stochastic offset strategy for the design of optimized RF pulses and time-varying spatially non-linear ΔB shim array fields for restricted slice excitation and refocusing with refined magnetization profiles within the intervals of the fixed voxels.

Methods: Our framework uses the decomposition property of the Bloch equations to enable joint design of RF-pulses and shim array fields for restricted slice excitation and refocusing with auto-differentiation optimization. Bloch simulations are performed independently on orthogonal basis vectors, Mx, My, and Mz, which enables designs for arbitrary initial magnetizations. Requirements for refocusing pulse designs are derived from the extended phase graph formalism obviating time-consuming sub-voxel isochromatic simulations to model the effects of crusher gradients. To refine resultant slice-profiles because of voxelwise optimization functions, we propose an algorithm that stochastically offsets spatial points at which loss is computed during optimization.

Results: We first applied our proposed design framework to standard slice-selective excitation and refocusing pulses in the absence of non-linear ΔB shim array fields and compared them against pulses designed with Shinnar-Le Roux algorithm. Next, we demonstrated our technique in a simulated setup of fetal brain imaging in pregnancy for restricted-slice excitation and refocusing of the fetal brain.

Conclusions: Our proposed framework for optimizing RF pulse and time-varying spatially non-linear ΔB shim array fields achieve high fidelity restricted-slice excitation and refocusing for fetal MRI, which could enable zoomed fast-spin-echo-MRI and other applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10699120PMC
http://dx.doi.org/10.1002/mrm.29827DOI Listing

Publication Analysis

Top Keywords

shim array
20
array fields
20
excitation refocusing
20
non-linear Δb
16
Δb shim
16
restricted slice
12
slice excitation
12
spatially non-linear
12
time-varying spatially
8
fields restricted
8

Similar Publications

∆B shim optimization performed at the beginning of an MR scan is unable to correct for ∆B field inhomogeneities caused by patient motion or hardware instability during scans. Navigator-based methods have been demonstrated previously to be effective for motion and shim correction. The purpose of this work was to accelerate volumetric navigators to allow fast acquisition of the parent navigated sequence with short real-time feedback time and high spatial resolution of the ∆B field mapping.

View Article and Find Full Text PDF

Anti-Parkinsonian 4-hydroxy-2-pyridones from an endolichenic fungus, Tolypocladium sp. (strain CNC14).

J Ind Microbiol Biotechnol

September 2025

Natural Products Research Institute, College of Pharmacy, Seoul National University, Seoul 08826, Republic of Korea.

4-Hydroxy-2-pyridone alkaloids have attracted considerable attention because of their intriguing structures and diverse bioactivities. In our previous study, 4-hydroxy-2-pyridone alkaloids were shown to exhibit potent activity against neuron-associated targets. To discover this class of neuroactive compounds, an array of endolichenic fungal extracts was screened by analyzing LC-UV-MS profiles.

View Article and Find Full Text PDF

Three-dimensional agitated saline contrast transesophageal echocardiography for the diagnosis of patent foramen ovale.

Sci Rep

August 2025

Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.

Patent foramen ovale (PFO) is a three-dimensional (3D) and dynamic structure, making diagnosis challenging with 2D imaging. We aimed to develop a practical 3D agitated saline contrast (ASC) transesophageal echocardiography (TEE) protocol, assess its feasibility, and evaluate its diagnostic implications in ischemic stroke patients. In 158 ischemic stroke patients (52 women; age: 63.

View Article and Find Full Text PDF

The ability to control the orientation and arrangement of plasmonic nanoparticles with shape anisotropy offers a promising route to achieving highly tunable optical properties. In this study, we introduce a synthetic approach for magnetically controllable plasmonic nanoparticles (MPs) consisting of an anisotropic gold core encapsulated by an iron oxide shell. The superparamagnetic property of the iron oxide shell enables rapid, reversible, and remotely controlled alignment of MPs, allowing for dynamic manipulation of their optical properties.

View Article and Find Full Text PDF

Traditional wearable ultrasound devices pose challenges concerning the rigidity and environmental impact of lead-based piezoelectric materials. This study proposes a silicon nanocolumn capacitive micromachined ultrasonic transducer (snCMUT) array for real-time wearable ultrasound imaging in disposable patches. Using a lead-free design, snCMUT incorporates silicon nanocolumns to address existing issues and achieves high transmission efficiency (220 kPa/V), flexibility, and low power consumption.

View Article and Find Full Text PDF