Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
∆B shim optimization performed at the beginning of an MR scan is unable to correct for ∆B field inhomogeneities caused by patient motion or hardware instability during scans. Navigator-based methods have been demonstrated previously to be effective for motion and shim correction. The purpose of this work was to accelerate volumetric navigators to allow fast acquisition of the parent navigated sequence with short real-time feedback time and high spatial resolution of the ∆B field mapping. A GRAPPA-accelerated 3D dual-echo EPI vNav was implemented on a 3 T Prisma MRI scanner. Testing was performed on an anthropomorphic head phantom and 11 human participants. vNav-derived ∆B field maps with various spatial resolutions were compared to Cartesian-encoded gold-standard 3D gradient-echo ∆B field mapping. ∆B shimming was evaluated for the scanner's spherical harmonics shims and a custom-made AC/DC RF-receive/∆B-shim array. The performance of dual-echo and single-echo accelerated navigators was compared for tracking and updating ∆B field maps during motion. Real-time motion and shim corrections for 2D MRI and 3D MRSI sequences were assessed in vivo with controlled head movement. Up to 8-fold acceleration of volumetric navigators (vNavs) significantly reduced geometric distortions and signal dropouts near air-tissue interfaces and metal implants. Acceleration allowed a flexible tradeoff between spatial resolution (2.5-7.5 mm) and acquisition time (242-1302 ms). Notably, accelerated high-resolution (5 mm) vNav was faster (378 ms) than unaccelerated low-resolution (7.5 mm) vNav (700 ms) and showed better agreement with 3D-GRE ∆B field mapping with 5.5 Hz RMSE, 1 Hz bias, and [-10%, +10%] confidence interval. Accelerated vNavs improved 3D MRSI and 2D MRI in real-time motion and shim correction applications. Advanced shimming with spherical harmonic and shim array showed superior ΔB correction, especially with joint shim optimization. GRAPPA-accelerated vNavs provide fast, robust, and high-quality ∆B field mapping and shimming over the whole-brain. The accelerated vNavs enable rapid correction of ∆B field inhomogeneities and faster acquisition of the navigated parent sequence. This methodology can be used for real-time motion and shim correction to enhance data quality in various MRI applications.