98%
921
2 minutes
20
Objective: The minimally invasive treatment of pelvic fractures is one of the most challenging trauma orthopedics surgeries, where preoperative planning is crucial for the performance and outcome of the surgery. However, planning the ideal position of fragments currently relies heavily on the experience of the surgeon.
Methods: A pelvic fracture virtual reduction algorithm for target position is provided based on statistical shape models (SSM). First, according to sexual dimorphism, pelvic SSM based on point cloud curvature down-sampling are constructed as adaptive templates. Then, an optimization algorithm is designed to iteratively adjust the target pose of the fragments and the adaptive matching of the templates. Finally, the feasibility of the method is verified by simulating fractures and clinical data.
Results: The pelvis has complex shape characteristics, which can be analyzed by SSM to clearly understand the pattern of change. Experiments showed that the SSM-based pelvic fracture reduction method had translation and rotation errors of 2.20±1.09 mm and 3.16±1.26° in simulated cases, and 2.78±0.95 mm and 3.10±0.53° in clinical cases, which has higher accuracy than methods based on mean shape models, and wider applicability than methods based on pelvic symmetry.
Conclusion: The pelvic digital model created by SSM has good generalization properties, and the SSM-based virtual reduction algorithm can effectively reconstruct the target position of the fractured pelvis in preoperative planning.
Significance: The proposed reduction method has the characteristics of high precision and wide application range, which provides a powerful tool for the surgeon's virtual preoperative planning.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TBME.2023.3272007 | DOI Listing |
Anesth Prog
September 2025
Objective: The purpose of this study was to compare nitrous oxide (N2O) vs virtual reality (VR) as methods for reducing pain and anxiety during a dental injection. The primary objectives were to assess acute changes in stress responses by comparing salivary cortisol levels between the 2 groups and differences in injection pain scores.
Methods: A total of 132 female subjects serving as their own control received maxillary lateral incisor infiltration injections with the use of either N2O or a VR headset during separate appointments spaced at least 2 weeks apart.
Jpn J Radiol
September 2025
Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221002, Jiangsu, China.
Background: Stroke, frequently associated with carotid artery disease, is evaluated using carotid computed tomography angiography (CTA). Dual-energy CTA (DE-CTA) enhances imaging quality but presents challenges in maintaining high image clarity with low-dose scans.
Objectives: To compare the image quality of 50 keV virtual monoenergetic images (VMI) generated using Deep Learning Image Reconstruction (DLIR) and Adaptive Statistical Iterative Reconstruction-V (ASIR-V) algorithms under a triple-low scanning protocol in carotid CTA.
Background And Aims: Whereas the value of endoscopic retrograde cholangiopancreatography (ERCP) training in clinical practice is well known, the impact on stress markers and performance in a virtual reality (VR) simulator is not. The primary aim of the study was to see how the number of clinical ERCPs performed during a 1-year period influenced VR-ERCP performance. A secondary aim was to compare differences in salivary stress marker levels, between the first and final simulator attempts.
View Article and Find Full Text PDFJ Telemed Telecare
September 2025
Centre for Innovative Medical Technology, Odense University Hospital, Odense, Denmark.
IntroductionThe use of digital solutions including patient-reported outcomes is limited to follow-up of patients with established diagnoses but is rarely used as first step of the diagnostic process substituting a personal contact with a health professional. We report on the diagnostic validity and cost per patient implications based on a feasibility study of a new virtual diagnostic service (VDS) for common neurological sleep disorders that, as a first step, involves the collection and automated analysis of self-reported digital patient data.MethodsThe VDS was established at the Odense University Hospital, Denmark.
View Article and Find Full Text PDFInterv Neuroradiol
September 2025
Department of Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
PurposeTo evaluate the potential of Photon-Counting Detector CT Angiography (PCD-CTA) for the assessment of carotid and subclavian artery stents compared to digital subtraction angiography (DSA) and Duplex ultrasound (DUS).MethodsThis study is a single-center, retrospective analysis of consecutive patients treated with a stent for high grade stenosis of the extra-cranial carotid and the subclavian artery between April 2023 and May 2024. Polyenergetic images (PE), iodine and virtual monoenergetic images were performed at different keV levels (40 and 80) and with two body vascular reconstruction kernels (Bv56 and 72) with and without iterative metal artifact reduction.
View Article and Find Full Text PDF