Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Although increased left ventricular (LV) mass is associated with adverse outcomes, measured values vary widely depending on the specific technique used. Moreover, the impact of sex, age, and race on LV mass remains controversial, further limiting the clinical use of this parameter. Accordingly, the authors studied LV mass using a variety of two-dimensional and three-dimensional echocardiographic techniques in a large population of normal subjects encompassing a wide range of ages.

Methods: Transthoracic echocardiograms obtained from 1,854 healthy adult subjects (52% men) enrolled in the World Alliance Societies of Echocardiography (WASE) Normal Values Study, were divided into three age groups (young, 18-35 years; middle aged, 36-55 years; and old, >55 years). LV mass was obtained using five conventional techniques, including linear and two-dimensional methods, as well as direct three-dimensional measurement. All LV mass values were indexed to body surface area, and differences according to sex, age, and race were analyzed for each technique.

Results: LV mass values differed significantly among the five techniques. Three-dimensional measurements were considerably smaller than those obtained using the other techniques and were closer to magnetic resonance imaging normal values reported in the literature. For all techniques, LV mass in men was significantly larger than in women, with and without body surface area indexing. These technique- and sex-related differences were larger than measurement variability. In women, age differences in LV mass were more pronounced and depicted significantly larger values in older age groups for all techniques, except three-dimensional echocardiography, which showed essentially no differences. LV mass was overall larger in black subjects than in white or Asian subjects.

Conclusions: Significant differences in LV mass values exist across echocardiographic techniques, which are therefore not interchangeable. Sex-, race-, and age-related differences underscore the need for separate population specific normal values.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2022.12.016DOI Listing

Publication Analysis

Top Keywords

normal values
20
mass values
12
differences mass
12
mass
11
values
9
left ventricular
8
ventricular mass
8
two-dimensional three-dimensional
8
three-dimensional echocardiography
8
alliance societies
8

Similar Publications

Objective: To develop a score (Palineo score) to identify the palliative care needs of newborn patients admitted to a Brazilian neonatal intensive care unit of a tertiary maternity hospital that serves as a reference center for high-risk pregnancies, ensuring timely follow-up by a specialist.

Methods: Patients were assessed by three specialists using a questionnaire that included the same clinical elements as those used for the Palineo score but did not assign scores to the criteria. The score was determined by the consensus reached by the specialists.

View Article and Find Full Text PDF

[Biomonitoring of military firefighters working in Brumadinho/MG, Brazil, after the breakdown of the tailing dam].

Cien Saude Colet

August 2025

Setor de Elementos Inorgânicos, Departamento de Química, Instituto Nacional de Controle de Qualidade em Saúde, Fundação Oswando Cruz. Av. Brasil 4365, Manguinhos. 21040-900 Rio de Janeiro RJ Brasil.

In January 2019, the state of Minas Gerais was struck by an environmental tragedy resulting from the collapse of the Córrego do Feijão Mine Dam, in Brumadinho. On this occasion, the Military Fire Brigade of the State of Rio de Janeiro (CBMERJ) designated specialized teams for emergency intervention, in aid of agents from the local corporation involved in providing care and support to victims and residents of the affected areas. However, these professionals were exposed to mud containing substances that cause harm to health.

View Article and Find Full Text PDF

This study assessed the effect of saliva exposure on roughness (Ra) and Vickers hardness (VHN) of two direct restorative materials, enamel, and dentin adjacent to the restorations. Enamel and dentin cavities in molars (n = 10) were restored with a) bulk-fill resin composite (Tetric N-Flow Bulk Fill, BF) with the application of a universal adhesive (Tetric N-Bond Universal) and b) alkasite restorative material (Cention N, CN) with and without the application of a universal adhesive. After 24 h (baseline), surface roughness and hardness of the restorative material and dental tissues were assessed at 100 μm from the tooth/restoration interface.

View Article and Find Full Text PDF

The aim of this in-vitro study was to verify which field of view (FOV) in cone-beam computed tomography (CBCT) yields greater accuracy in the detection of internal root resorption (IRR) volume, in comparison to the gold standard of micro-computed tomography (micro-CT) and to a physical method. Twenty-five extractedsingle-rooted teeth were scanned by CBCT with two different FOV parameters (6x6-FOV and 10x10-FOV) and via micro-CT. The volume of dental hard tissue was measured on these images.

View Article and Find Full Text PDF

Tumor necrosis factor-alpha (TNF-α) is a cytokine involved in the immune-inflammatory response. It can induce an odontoblastic phenotype and enhance biomineralization in dental pulp mesenchymal stem cells but does not have the same effect on osteoblasts. The reasons for this differential response, despite the shared lineage of these cell types, are not yet clear.

View Article and Find Full Text PDF