Background: Although international guidelines recommend not fixing the mesh in almost all cases of laparoendoscopic repairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of high-quality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials.
Method: The authors conducted an experiment with scientists from Universities of Technology in a model that reflects the conditions in the groin area. By simulating conditions of the highest possible intra-abdominal pressure, they examined the mesh behavior within the groin and its ability to dislocate under the forces generated by this pressure. The experiment involved six spatial implants and one flat macroporous mesh.
Results: Heavyweight spatial meshes and lightweight spatial-individualized meshes showed no tendency to dislocate or move directly to the orifice, which was considered a rapid hernia recurrence. Lightweight meshes, both spatial and flat, underwent significant migration and shifting toward the hernial orifices.
Conclusion: Based on the results, we believe that mesh fixation is not the only alternative to preventing recurrence in complex defects. Similar effects can be achieved using a larger, more rigid, and anatomically fitted implant. The type of implant (rather than its fixation) seems to be a key factor from the point of view of mechanics and biophysics. Clinical trials confirming the results in vivo will allow to supplement or amend the guidelines for the treatment of large inguinal hernias.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00464-022-09699-5 | DOI Listing |
Front Med (Lausanne)
August 2025
Department of General Surgery, Affiliated Hospital of Hebei University, Baoding, Hebei, China.
De Garengeot hernia, characterized by appendiceal incarceration within a femoral canal hernia sac, is a rare condition with high risks of strangulation. Traditional open repair remains standard, but laparoscopic approaches offer minimally invasive alternatives. However, limited evidence exists on combining laparoscopic transabdominal preperitoneal (TAPP) with biologic mesh for this condition.
View Article and Find Full Text PDFZhongguo Gu Shang
August 2025
Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo 315040, Zhejiang, China.
Objective: To establish a two-segment vertebrectomy model using the finite element method, and to measure and compare the biomechanical properties of the lower cervical anterior transpedicular root screw (ATPRS) plate system, lower cervical anterior pedicle screw (ATPS) plate system, and lower cervical anterior cervical locked-plate (ACLP) system on this model.
Methods: CT data of the cervical spine (C-T) from a 34-year-old healthy adult male volunteer were collected. A nonlinear complete model of the lower cervical spine (C-C) was established using Mimics 10.
Plast Surg (Oakv)
August 2025
Division of Plastic Surgery, Department of Surgery, University of Alberta, Edmonton, AB, Canada.
Surgical repair of orbital fractures comes with risks. One rare risk is interference with the actions of the superior oblique tendon-muscle complex causing an acquired Brown syndrome. We present the case of a 45-year-old man who developed acquired Brown syndrome after undergoing repair of a large orbital floor and medial orbital wall fracture using a titanium mesh implant.
View Article and Find Full Text PDFActa Biomater
August 2025
Shanghai Frontiers Science Center of Advanced Textiles, College of Textiles, Donghua University, Shanghai 201620, China; Key Laboratory of Textile Science &Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China; Key Laboratory of Textile Industry for Biome
Microneedle patches can penetrate the myocardium to facilitate integration with cardiac tissue, offering a promising approach for myocardial infarction (MI) repair. However, their clinical translation has been hindered by insufficient fixation stability during cardiac contractions and mismatch with myocardial anisotropy. To address these challenges, a bioinspired three-dimensional cardiac patch integrating barbed microneedles and an anisotropic lightweight mesh was designed.
View Article and Find Full Text PDFSurg Innov
August 2025
Department of Surgery, Center for Perioperative Optimization, Copenhagen University Hospital Herlev and Gentofte, Herlev, Denmark.
BackgroundThere is currently insufficient evidence to determine whether lightweight or heavyweight mesh is the better choice for ventral hernias. Recurrence and postoperative pain are associated with biomechanical responses such as inflammation, foreign body reaction, cell ingrowth, and tensile strength, which can be examined in animal studies. This study aimed to compare the biomechanical differences between light- and heavyweight meshes in animal models.
View Article and Find Full Text PDF