Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background and objectives: Ocular ultrasound is a core application of point-of-care ultrasound (POCUS) to assist physicians in promptly identifying various ocular diseases at the bedside; however, hands-on POCUS training is challenging during a pandemic. Materials and Methods: A randomized controlled non-inferiority trial was conducted in an academic emergency department from October 2020 to April 2021. Thirty-two participants were randomly assigned to one of two groups. Group H (hands-on learning group) participated individually in a hands-on session with a standardized patient for 30 min, whereas Group O (online learning group) learned training materials and video clips for 20 min. They scanned four eyeballs of two standardized patients sequentially following the ocular POCUS scan protocol. Repeated POCUS scans were performed 2 weeks later to assess skill maintenance. Both groups completed the pre- and post-surveys and knowledge tests. Two emergency medicine faculty members blindly evaluated the data and assigned a score of 0−25. The primary endpoint was the initial total score of scan quality evaluated using non-inferiority analysis (generalized estimating equation). The secondary endpoints were total scores for scan quality after 2 weeks, scan time, and knowledge test scores. Results: The least squares means of the total scores were 21.7 (0.35) for Group O and 21.3 (0.25) for Group H, and the lower bound of the 95% confidence interval (CI) was greater than the non-inferiority margin of minus 2 (95% CI: −0.48−1.17). The second scan scores were not significantly different from those of the first scan. The groups did not differ in scanning time or knowledge test results; however, Group H showed higher subjective satisfaction with the training method (p < 0.001). Conclusion: This study showed that basic online ocular ultrasound education was not inferior to hands-on education, suggesting that it could be a useful educational approach in the pandemic era.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9315691PMC
http://dx.doi.org/10.3390/medicina58070960DOI Listing

Publication Analysis

Top Keywords

ocular ultrasound
12
online learning
8
hands-on learning
8
randomized controlled
8
controlled non-inferiority
8
non-inferiority trial
8
learning group
8
scan quality
8
total scores
8
scores scan
8

Similar Publications

Purpose: The purpose of this study was to investigate the focal relationship between choroidal thickness and retinal sensitivity in myopic eyes.

Methods: Participants underwent swept-source optical coherence tomography (SS-OCT) imaging and microperimetry testing. Choroidal thicknesses were obtained by segmenting the SS-OCT scans using a deep-learning approach.

View Article and Find Full Text PDF

Purpose: To compare postoperative vault measurements between horizontal and vertical fixation of the Implantable Collamer Lens (ICL) (KS-AquaPORT; STAAR Surgical) when its size is determined using the KS formula.

Methods: This retrospective study analyzed 2,343 eyes from 1,275 patients who underwent myopic ICL implantation. Pre-operative anterior segment optical coherence tomography (AS-OCT) (CASIA 2; Tomey Corporation) was performed in both horizontal and vertical orientations.

View Article and Find Full Text PDF

Background: Ocular imaging is essential to the diagnosis and management of eye disease, yet standardized imaging workflows remain underdeveloped in the eye care setting. This manuscript describes the design and implementation of an orders-based imaging workflow for ambulatory ophthalmology integrated with the electronic health record and enterprise imaging systems.

Methods: We developed a DICOM-compliant workflow for pediatric ophthalmology imaging that supports HL7 integration, DICOM modality worklists, and enterprise archive storage.

View Article and Find Full Text PDF

Macular Optical Coherence Tomography Parameters and Incident Glaucoma Among Myopic Eyes.

Transl Vis Sci Technol

September 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, People's Republic of China.

Purpose: The purpose of this study was to estimate the correlations between macular optical coherence tomography (OCT)-derived metrics and incident glaucoma risk in myopic eyes.

Methods: This longitudinal observational study included 24,181 individuals with myopia (spherical equivalence [SE] ≤ -0.5 diopters [D]) from the UK Biobank study.

View Article and Find Full Text PDF

Spinocerebellar ataxia type 27B (SCA27B), caused by GAA repeat expansions in FGF14, is an increasingly recognized form of late-onset cerebellar ataxia. However, early diagnosis remains challenging due to mild or absent cerebellar motor signs and often normal brain magnetic resonance imaging (MRI). Oculovestibular abnormalities, although prevalent, are frequently overlooked and not captured by standard clinical scales such as the Scale for the Assessment and Rating of Ataxia (SARA).

View Article and Find Full Text PDF