Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Ocular imaging is essential to the diagnosis and management of eye disease, yet standardized imaging workflows remain underdeveloped in the eye care setting. This manuscript describes the design and implementation of an orders-based imaging workflow for ambulatory ophthalmology integrated with the electronic health record and enterprise imaging systems.

Methods: We developed a DICOM-compliant workflow for pediatric ophthalmology imaging that supports HL7 integration, DICOM modality worklists, and enterprise archive storage. Workflow steps were automated where possible, including imaging order placement, metadata application, and documentation. Pre- and post-implementation workflows were evaluated for efficiency, measuring mouse clicks, keystrokes, and time to completion. Imaging study volumes and billing data were collected following implementation.

Results: Thirteen imaging devices across six modalities and five locations were integrated. The new workflow reduced manual data entry and enabled structured documentation. Post-implementation, 16,267 imaging studies were completed, generating $11.4 million in billed charges. Workflow efficiency improved, with keystrokes and mouse clicks reduced by 40-86% depending on modality. Time savings were observed in most modalities, although optical coherence tomography and B-scan ultrasound required more time due to order-specific imaging steps.

Conclusion: An orders-based imaging workflow for ophthalmology can improve efficiency, standardization, and interoperability while enabling proper image archiving and billing. Challenges remain with vendor variability in DICOM support and image output formats. These findings support broader adoption of standardized imaging practices in ophthalmology.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10278-025-01660-xDOI Listing

Publication Analysis

Top Keywords

imaging
13
imaging workflow
12
ophthalmology imaging
8
standardized imaging
8
orders-based imaging
8
mouse clicks
8
workflow
7
ophthalmology
5
development implementation
4
implementation ambulatory
4

Similar Publications

Carbon dots (CDs) represent a new class of nontoxic and sustainable nanomaterials with increasing applications. Among them, bright and large Stokes-shift CDs are highly desirable for display and imaging, yet the emission mechanisms remain unclear. We obtained structural signatures for the recently engineered green and red CDs by ground-state femtosecond stimulated Raman spectroscopy (FSRS), then synthesized orange CDs with similar size but much higher nitrogen dopants than red CDs.

View Article and Find Full Text PDF

Prolonging All-Optical Molecular Electron Spin Coherence in the Tissue Transparency Window.

J Am Chem Soc

September 2025

Division of Chemistry and Chemical Engineering, Arthur Amos Noyes Laboratory of Chemical Physics, California Institute of Technology, Pasadena, California 91125, United States.

Coherent electron spin states within paramagnetic molecules hold significant potential for microscopic quantum sensing. However, all-optical coherence measurements amenable to high spatial and temporal resolution under ambient conditions remain a significant challenge. Here we conduct room-temperature, picosecond time-resolved Faraday ellipticity/rotation (TRFE/R) measurements of the electron spin decoherence time in [IrBr].

View Article and Find Full Text PDF

Importance: Cannabis is the most commonly used illicit drug, with 10% to 30% of regular users developing cannabis use disorder (CUD), a condition linked to altered hippocampal integrity. Evidence suggests high-intensity interval training (HIIT) enhances hippocampal structure and function, with this form of physical exercise potentially mitigating CUD-related cognitive and mental health impairments.

Objective: To determine the impact of a 12-week HIIT intervention on hippocampal integrity (ie, structure, connectivity, biochemistry) compared with 12 weeks of strength and resistance (SR) training in CUD.

View Article and Find Full Text PDF

Importance: Multiparametric magnetic resonance imaging (MRI), with or without prostate biopsy, has become the standard of care for diagnosing clinically significant prostate cancer. Resource capacity limits widespread adoption. Biparametric MRI, which omits the gadolinium contrast sequence, is a shorter and cheaper alternative offering time-saving capacity gains for health systems globally.

View Article and Find Full Text PDF