Analysis of LoRaWAN 1.0 and 1.1 Protocols Security Mechanisms.

Sensors (Basel)

School of Electronic and Electrical Engineering, Kyungpook National University, Daegu 41566, Korea.

Published: May 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

LoRaWAN is a low power wide area network (LPWAN) technology protocol introduced by the LoRa Alliance in 2015. It was designed for its namesake features: long range, low power, low data rate, and wide area networks. Over the years, several proposals on protocol specifications have addressed various challenges in LoRaWAN, focusing on its architecture and security issues. All of these specifications must coexist, giving rise to the compatibility issues impacting the sustainability of this technology. This paper studies the compatibility issues in LoRaWAN protocols. First, we detail the different protocol specifications already disclosed by the LoRa Alliance in two major versions, v1.0 and v1.1. This is done through presenting two scenarios where we discuss the communication and security mechanisms. In the first scenario, we describe how an end node (ED) and network server (NS) implementing LoRaWAN v1.0 generate session security keys and exchange messages for v1.0. In the second scenario, we describe how an ED v1.1 and an NS v1.1 communicate after generating security session keys. Next, we highlight the compatibility issues between the components implementing the two different LoRaWAN Specifications (mainly v1.0 and v1.1). Next, we present two new scenarios (scenarios 3 and 4) interchanging the ED and NS versions. In scenario three, we detail how an ED implementing LoRaWAN v1.1 communicates with an NS v1.0. Conversely, in scenario four, we explain how an ED v1.0 and an NS v1.1 communicate. In all these four scenarios, we highlight the concerns with security mechanism: show security session keys are generated and how integrity and confidentiality are guaranteed in LoRaWAN. At the end, we present a comparative table of these four compatibility scenarios.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9142980PMC
http://dx.doi.org/10.3390/s22103717DOI Listing

Publication Analysis

Top Keywords

compatibility issues
12
v10 v11
12
implementing lorawan
12
lorawan protocols
8
security mechanisms
8
low power
8
wide area
8
lora alliance
8
protocol specifications
8
scenario describe
8

Similar Publications

Skull base surgery requires precise spatial recognition; however, existing educational tools remain limited. To address this issue, we developed a step-by-step stereotactic three-dimensional anatomical model of the anterior transpetrosal approach using digital photogrammetry. Cadaveric dissection was subsequently performed in 17 steps, of which 10 were reconstructed into three-dimensional models.

View Article and Find Full Text PDF

The miniaturization of separation platforms marks a transformative shift in analytical science, merging microfabrication, automation, and intelligent data integration to meet rising demands for portability, sustainability, and precision. This review critically synthesizes recent technological advances reshaping the field-from microinjection and preconcentration modules to compact, high-sensitivity detection systems including ultraviolet-visible (UV/Vis), fluorescence (FL), electrochemical detection (ECD), and mass spectrometry (MS). The integration of microcontrollers, AI-enhanced calibration routines, and IoT-enabled feedback loops has led to the rise of self-regulating analytical devices capable of real-time decision-making and autonomous operation.

View Article and Find Full Text PDF

Surface engineering of cellulose microspheres via amyloid-like protein aggregation for bilirubin removal.

Carbohydr Polym

November 2025

College of Chemistry and Molecular Sciences, Key Laboratory of Biomedical Polymers of Ministry of Education, Wuhan University, Wuhan 430072, China. Electronic address:

Hemoperfusion is one of the most effective blood purification techniques to quickly remove bilirubin from the blood of patients with kidney or liver failure. Although numerous adsorbent materials with high adsorption capacity have been developed, their clinical application are still limited due to poor biocompatibility and biosafety issues. Herein, biocompatible core-shell structured adsorbents with cellulose microspheres (CMs) as the supporting core and phase-transformed lysozyme (PTL) as the functional shell are fabricated for the removal of bilirubin in hemoperfusion.

View Article and Find Full Text PDF

In-Built Compatible Electrode-Electrolyte Interphases for Quasi-Solid-State Li-SPAN Batteries.

Angew Chem Int Ed Engl

September 2025

Shandong Key Laboratory of Advanced Chemical Energy Storage and Intelligent Safety, Advanced Technology Research Institute, Beijing Institute of Technology, Jinan, 250300, China.

Lithium-sulfur batteries have been regarded as a promising candidate for next-generation energy storage systems owing to their high energy density and low cost. Sulfurized polyacrylonitrile (SPAN) as a cathode material has received wide interest due to the solid-solid conversion mechanism, while the Li-SPAN cell performance has been limited by the notorious issue of lithium metal anode. Developing solid-state electrolytes for lithium-sulfur batteries with favorable electrode-electrolyte compatibility is urgently desired.

View Article and Find Full Text PDF

Background: Fluid overload-a critical risk in pediatric/neonatal care-is often driven by excessive fluid during medication dilution, increasing complications like acute kidney injury(AKI), prolonged ventilation, and mortality.

Methods: A 2024 cross-sectional study across 14 pediatric units (PICUs, NICUs, surgical/general wards) evaluated fluid administration practices and nurses' knowledge. Observations included 150 patients and 200 nurses administering 8 medications.

View Article and Find Full Text PDF