Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Personalized cardiac modeling is widely used for studying the mechanisms of cardiac arrythmias. Due to the high demanding of computational resource of modeling, the arrhythmias induced in the models are usually simulated for just a few seconds. In clinic, it is common that arrhythmias last for more than several minutes and the morphologies of reentries are not always stable, so it is not clear that whether the simulation of arrythmias for just a few seconds is long enough to match the arrhythmias detected in patients. This study aimed to observe how long simulation of the induced arrhythmias in the personalized cardiac models is sufficient to match the arrhythmias detected in patients. A total of 5 contrast enhanced MRI datasets of patient hearts with myocardial infarction were used in this study. Then, a classification method based on Gaussian mixture model was used to detect the infarct tissue. For each reentry, 3 s and 10 s were simulated. The characteristics of each reentry simulated for different duration were studied. Reentries were induced in all 5 ventricular models and sustained reentries were induced at 39 stimulation sites in the model. By analyzing the simulation results, we found that 41% of the sustained reentries in the 3 s simulation group terminated in the longer simulation groups (10 s). The second finding in our simulation was that only 23.1% of the sustained reentries in the 3 s simulation did not change location and morphology in the extended 10 s simulation. The third finding was that 35.9% reentries were stable in the 3 s simulation and should be extended for the simulation time. The fourth finding was that the simulation results in 10 s simulation matched better with the clinical measurements than the 3 s simulation. It was shown that 10 s simulation was sufficient to make simulation results stable. The findings of this study not only improve the simulation accuracy, but also reduce the unnecessary simulation time to achieve the optimal use of computer resources to improve the simulation efficiency and shorten the simulation time to meet the time node requirements of clinical operation on patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8739986PMC
http://dx.doi.org/10.3389/fphys.2021.733500DOI Listing

Publication Analysis

Top Keywords

simulation
20
simulation time
16
personalized cardiac
12
sustained reentries
12
location morphology
8
cardiac modeling
8
reentries stable
8
match arrhythmias
8
arrhythmias detected
8
detected patients
8

Similar Publications

Accelerated failure time (AFT) models offer an attractive alternative to Cox proportional hazards models. AFT models are collapsible and, unlike hazard ratios in proportional hazards models, the acceleration factor-a key effect measure in AFT models-is collapsible, meaning its value remains unchanged when adjusting for additional covariates. In addition, AFT models provide an intuitive interpretation directly on the survival time scale.

View Article and Find Full Text PDF

Background: Identifying suspected anterior circulation large-vessel occlusion (aLVO) strokes during emergency calls could enhance dispatch efficiency, particularly in rural areas. However, data on emergency medical dispatchers' (EMDs) ability to recognize aLVO symptoms remain limited. This simulation study aimed to evaluate the feasibility of identifying side-specific arm paresis, side-specific conjugate eye deviation (CED), and aphasia during emergency calls by instructing layperson callers to perform brief, standardized examination steps.

View Article and Find Full Text PDF

Background: The increasing amount of data routinely collected on ICUs poses a challenge for clinicians which is aggravated with data-heavy therapies like Continuous Kidney Replacement Therapy (CKRT). We developed the CKRT Supporting Software Prototype (CKRT-SSP), a clinical decision support system for use before, during and after CKRT. The aim of this user experience (UX) study was to prospectively evaluate CKRT-SSP in terms of usability, user experience, and workload in a simulated ICU setting.

View Article and Find Full Text PDF

Impact of Flow Restrictors on Aerosol Delivery of the Respimat® Soft Mist Inhaler.

Pulm Ther

September 2025

Boehringer Ingelheim Pharma GmbH & Co. KG, Binger Straße 173, 55216, Ingelheim am Rhein, Germany.

Introduction: The modification of an inhaler's air flow resistance influences a patient's inhalation flow profile, thereby affecting the exit velocity of an aerosol leaving the Respimat® mouthpiece. A slower inhalation maneuver results in reduced plume velocity and thus a decreased oropharyngeal deposition due to reduced impaction. This could not only lead to fewer unwanted side effects associated with inhaled therapies, but also enhance lung deposition.

View Article and Find Full Text PDF

Introduction: This study explores high-impedance surface (HIS) metamaterial shields for enhancing the transmit field in whole-body MRI at 7 T. We studied the possibility of placing a metamaterial layer between the gradient coil and bore liner using electromagnetic simulations to evaluate B and SAR efficiency across different impedances.

Materials And Methods: Simulations were performed in three stages, first metamaterial design and characterization, then single-element dipole simulations with a homogenous phantom, and finally, simulations including a four-element arrays with a virtual body model, including the whole scanner geometry.

View Article and Find Full Text PDF