Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To compare the shaping ability of the XP-endo Shaper (XPS) system to the ProTaper Next (PTN) system in oval-shaped distal root canals.

Methods: From 12 mandibular molars, distal roots with moderately curved single oval canals were randomly assorted to be instrumented with XPS (experimental group) or PTN (control group) and then scanned using micro-computed tomography [Scan 1]. The root canals of the XPS samples were prepared following the manufacturer's instructions using 15 insertions (XPS15) and rescanned [Scan 2]. An additional 10 insertions to the working length were applied, totalling 25 insertions (XPS25), and the roots were rescanned again [Scan 3]. PTN samples were prepared up to the X3 instrument (PTNX3) and rescanned [Scan 2]. The dentine removed and the unprepared areas were assessed. Data were analysed using a t-test with significance at α=0.05.

Results: XPS25 was associated with a significantly greater dentine removal than XPS15 over the entire root canal length and in all three-thirds of the root canal (P<0.05). XPS25 significantly removed more dentine than PTNX3 in only the coronal third (P<0.05). XPS25 was also associated with a significantly smaller percentage of unprepared areas than XPS15 overall and in the coronal third (P<0.05). PTNX3 was associated with a significantly larger percentage of unprepared areas than XPS15 and XPS25 overall and in the coronal and middle thirds (P<0.05).

Conclusion: Ten additional movements with XPS significantly improved instrumentation capacity, reducing the percentage of untouched surface areas but also removing more dentine.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8842428PMC
http://dx.doi.org/10.14744/eej.2021.44153DOI Listing

Publication Analysis

Top Keywords

rescanned [scan
12
shaping ability
8
ability xp-endo
8
xp-endo shaper
8
oval-shaped distal
8
distal root
8
root canals
8
mandibular molars
8
samples prepared
8
root canal
8

Similar Publications

Background: To investigate the anatomical and dosimetric differences in target areas and organs at risk (OARs) after adjusting the radiotherapy schedule for nasopharyngeal carcinoma (NPC).

Methods: In total, 34 patients who underwent radiotherapy for NPC were selected. A new localization computed tomography (CT) scan was performed after 25th and before 26th fraction.

View Article and Find Full Text PDF

Purpose: To evaluate the laboratory effect of the cut-out-rescan procedure and the rubber dam color on the trueness of two intraoral scanners (IOS).

Methods: An onlay preparation was performed on a typodont maxillary left 1st molar. The left hemi-arch of the maxilla was scanned using two IOS (Trios 3, 3Shape; n=20).

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate and compare the marginal and internal fit of permanent crowns fabricated using three different DLP 3D printers and their corresponding permanent resin materials. The fit was quantitatively assessed using micro-computed tomography (micro-CT) and digital 3D analysis.

Materials And Methods: A premolar tooth was prepared according to conventional ceramic tooth preparation protocols and scanned with an intraoral scanner (TRIOS 5).

View Article and Find Full Text PDF

Background: Group cognitive behavioral therapy (GCBT) is increasingly being used to treat obsessive-compulsive disorder (OCD) because of its high efficiency, economy, and interaction among group members. However, the changes in network functional connectivity (FC) in patients with OCD with GCBT remain unclear.

Aim: To investigate inter- and intra-network resting-state FC (rs-FC) abnormalities before and after GCBT in unmedicated patients with OCD and validate the efficacy of GCBT.

View Article and Find Full Text PDF

The choroid plexus (CP) is important for cerebrospinal fluid (CSF) secretion and forms the blood-CSF barrier (BCSFB), which is essential for brain homeostasis. However, noninvasive methods for evaluating BCSFB function remain limited. Previously, we introduced a novel magnetic resonance imaging (MRI) technique, relaxation-exchange MRI (REXI), to quantify water exchange between CP and CSF in rats by leveraging the substantial difference in transverse relaxation times between CP tissue and CSF.

View Article and Find Full Text PDF