Article Abstract

Owing to the recent global spread of the new coronavirus SARS-CoV-2, the development of technology to effectively detect viruses in crowded public places is urgently needed. In this study, a three-stage high-volume bioaerosol sampler was developed for the size-selective sampling of bioaerosols through the suction of air at a high flow rate of 1000 L/min. In stage 1, an omnidirectional inlet cyclone separator that can draw air from all directions was applied to collect bioaerosols larger than 10 μm in the collection fluid. In stage 2, an axial flow cyclone separator was used to collect bioaerosols sized between 2.5 and 10 μm in the collection fluid. In stage 3, bioaerosols smaller than 2.5 μm were collected on a filter and extracted in a solution through an elution process using a sodium phosphate buffer. To simulate the suspension of bioparticles including viruses that are attached to other particles in the atmosphere, the aerosol samples were prepared by coagulating aerosolized bacteriophages with Arizona test dust. Then, the coagulated particles were collected for 30 min using the developed bioaerosol sampler, and the samples collected in each stage were analyzed via polymerase chain reaction (PCR) method. The PCR analysis results confirmed that the high-volume bioaerosol sampler enables size-selective bioaerosol sampling even at a high airflow rate of 1000 L/min. The developed high-volume bioaerosol sampler will be useful in detecting viruses through PCR analysis because it can collect bioaerosols within a specific size range.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8435071PMC
http://dx.doi.org/10.1016/j.atmosenv.2021.118720DOI Listing

Publication Analysis

Top Keywords

bioaerosol sampler
16
high-volume bioaerosol
12
collect bioaerosols
12
size-selective sampling
8
sampling bioaerosols
8
including viruses
8
rate 1000 l/min
8
cyclone separator
8
10 μm collection
8
collection fluid
8

Similar Publications

Detecting airborne viruses using an integrated aerosol sampling detection device is of great significance in epidemic prevention and control. Most of the applicable aerosol samplers have a flow rate of less than 1000 L/min, which is insufficient for application in large public spaces. Recent research, on the other hand, has revealed the advantages of microfluidic chip-based LAMP-CRISPR in airborne virus detection; however, this promising detection method has yet to be integrated with an aerosol sampler.

View Article and Find Full Text PDF

Quantifying Dissemination of Antibiotic Resistance Genes in Air from a Dairy Farm and Swine Farm.

ACS EST Air

August 2025

Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States.

Farms are a suspected source of dissemination of antibiotic resistance genes (ARGs) to the atmosphere, but their contribution remains poorly quantified. This study investigated the concentrations, emission rates, and particle size distributions of ARGs in air around a dairy farm and swine farm, as well as in farm wastewater and soil as potential sources, during a yearlong sampling campaign. Analysis targeted genes corresponding to a cross-section of antibiotic classes used in human and veterinary medicine, along with 16S rRNA and as indicators of total bacterial load and anthropogenic sources of ARGs, respectively.

View Article and Find Full Text PDF

Integrating air microbiome for comprehensive air quality analysis.

iScience

July 2025

AIRLAB, Climate and Health Group, CANU Programme, ISGlobal, 08003 Barcelona, Spain.

Air quality monitoring typically overlooks the biological composition of airborne particles, despite its relevance to human health. This study evaluated the feasibility of using filters from high-volume air samplers, widely employed in air quality networks, to analyze bioaerosol content through shotgun metagenomic sequencing. We developed a DNA extraction method for ultra-low biomass samples and assessed the impact of sampling duration, particle size selection, and filter material on microbial diversity.

View Article and Find Full Text PDF

Highlights: Fan exhaust air sampling is a reliable monitoring proxy for indoor bioaerosols from livestock operations. Air samples collected indoors and at fan exhaust have highly similar bacterial diversity. At low indoor concentrations, specific microbial markers are still detectable in the air collected at the fan exhaust.

View Article and Find Full Text PDF

Indoor air quality plays a crucial role in the health and well-being of residents. Delhi, known as one of the most polluted cities globally, often receives insufficient attention in managing and mitigating related health impacts. This study isolated, characterized, and assessed microbial indoor air quality (bioaerosols) using multiproxy approaches and correlated findings with associated health effects.

View Article and Find Full Text PDF