Anisotropy and anharmonicity in polystyrene stable glass.

J Chem Phys

Department of Physics and Astronomy, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada.

Published: December 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We have used ellipsometry to characterize the anisotropy in stable polymer glasses prepared by physical vapor deposition. These measurements reveal birefringence values (as measured by the magnitude of in-plane vs out-of-plane refractive index) less than 0.002 in vapor-deposited polystyrenes with N from 6 to 12 and with fictive temperatures between 10 K and 35 K below the T values. We have measured the thermal expansivity of these stable glasses and compared to ordinary rejuvenated glass. The thermal expansivity of the stable glasses is less than that of ordinary glass with a difference that increases as the fictive temperature T decreases.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0032153DOI Listing

Publication Analysis

Top Keywords

values measured
8
thermal expansivity
8
expansivity stable
8
stable glasses
8
anisotropy anharmonicity
4
anharmonicity polystyrene
4
stable
4
polystyrene stable
4
stable glass
4
glass ellipsometry
4

Similar Publications

Does a lifestyle-based intervention improve sleep quality in individuals with major depressive disorder? A randomized controlled trial.

Trends Psychiatry Psychother

September 2025

Laboratory of Hormone Measurement, Department of Physiology and Behavior, Federal University of Rio Grande do Norte, Natal, Brazil. Postgraduate Program in Psychobiology, Center for Biosciences, Federal University of Rio Grande do Norte, Natal, Brazil. National Institute of Science and Technology fo

Background: Major Depressive Disorder (MDD) is a leading cause of global disability, contributing to substantial individual, social, and economic burdens. While antidepressant therapy remains the cornerstone of treatment, complementary lifestyle-based interventions, such as multimodal exercise and mindfulness, have shown promise in alleviating mood symptoms. However, their specific impact on sleep quality, a critical therapeutic target in MDD, remains underexplored.

View Article and Find Full Text PDF

This study assessed the effect of saliva exposure on roughness (Ra) and Vickers hardness (VHN) of two direct restorative materials, enamel, and dentin adjacent to the restorations. Enamel and dentin cavities in molars (n = 10) were restored with a) bulk-fill resin composite (Tetric N-Flow Bulk Fill, BF) with the application of a universal adhesive (Tetric N-Bond Universal) and b) alkasite restorative material (Cention N, CN) with and without the application of a universal adhesive. After 24 h (baseline), surface roughness and hardness of the restorative material and dental tissues were assessed at 100 μm from the tooth/restoration interface.

View Article and Find Full Text PDF

The aim of this in-vitro study was to verify which field of view (FOV) in cone-beam computed tomography (CBCT) yields greater accuracy in the detection of internal root resorption (IRR) volume, in comparison to the gold standard of micro-computed tomography (micro-CT) and to a physical method. Twenty-five extractedsingle-rooted teeth were scanned by CBCT with two different FOV parameters (6x6-FOV and 10x10-FOV) and via micro-CT. The volume of dental hard tissue was measured on these images.

View Article and Find Full Text PDF

Tumor necrosis factor-alpha (TNF-α) is a cytokine involved in the immune-inflammatory response. It can induce an odontoblastic phenotype and enhance biomineralization in dental pulp mesenchymal stem cells but does not have the same effect on osteoblasts. The reasons for this differential response, despite the shared lineage of these cell types, are not yet clear.

View Article and Find Full Text PDF

The contamination of dental curing light tips was evaluated before and after treatment and after their use and disinfection. The influence of a plastic protective barrier over the flexural strength and the modulus of elasticity of resin composites were also analyzed. Microbiological sampling was conducted at initial contamination (T0), in Log 10 CFU/4 mL; after dental treatment (T1); and after disinfection with 70% ethanol (v/v) (T2).

View Article and Find Full Text PDF