Article Abstract

Metabolic bone disease (MBD) is one of the major complications of prematurity. Ultrasonic backscatter technique has the potential to be a portable and noninvasive method for early diagnosis of MBD. This study firstly applied CAS to neonates, which was defined as a linear combination of the apparent integrated backscatter coefficient (AIB) and spectral centroid shift (SCS). The objective was to evaluate the feasibility of ultrasonic backscatter technique for assessing neonatal bone health using AIB, SCS, and CAS. Ultrasonic backscatter measurements at 3.5 MHz, 5.0 MHz, and 7.5 MHz were performed on a total of 505 newborns within 48 hours after birth. The values of backscatter parameters were calculated and compared among gestational age groups. Correlations between backscatter parameters, gestational age, anthropometric indices, and biochemical markers were analyzed. The optimal predicting models for CAS were determined. The results showed term infants had lower SCS and higher AIB and CAS than preterm infants. Gestational age and anthropometric indices were negatively correlated with SCS (|| = 0.45 - 0.57,  < 0.001), and positively correlated with AIB (|| = 0.36 - 0.60,  < 0.001) and CAS (|| = 0.56 - 0.69,  < 0.001). Biochemical markers yielded weak or nonsignificant correlations with backscatter parameters. CAS had relatively stronger correlations with the neonatal variables than AIB and SCS. At 3.5 MHz and 5.0 MHz, only gestational age ( < 0.001) independently contributed to the measurements of CAS, and could explain up to 40.5% - 44.3% of CAS variation. At 7.5 MHz, the combination of gestational age ( < 0.001), head circumference ( = 0.002), and serum calcium ( = 0.037) explained up to 40.3% of CAS variation. This study suggested ultrasonic backscatter technique was feasible to evaluate neonatal bone status. CAS was a promising parameter to provide more information about bone health than AIB or SCS alone.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7211244PMC
http://dx.doi.org/10.1155/2020/3187268DOI Listing

Publication Analysis

Top Keywords

ultrasonic backscatter
16
gestational age
12
backscatter technique
8
backscatter parameters
8
age anthropometric
8
anthropometric indices
8
backscatter
7
combined ultrasonic
4
backscatter parameter
4
parameter bone
4

Similar Publications

This study investigates a non-destructive, compact pulse-echo ultrasonic method that combines an external transmitter with a single receiving sensor to identify different surface treatments applied to cementitious materials. The primary objective was to evaluate whether treatment-induced acoustic changes could be reliably quantified using time-domain signal parameters. Three types of surface conditions were examined: untreated reference specimens (R), specimens treated with a standard lithium silicate solution (A), and those treated with an enriched formulation containing hexylene glycol (B) intended to enhance pore sealing via gelation.

View Article and Find Full Text PDF

Optical focusing into scattering media via iterative time reversal guided by absorption nonlinearity.

Nat Commun

August 2025

Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA.

Guide star-assisted time-reversal enables deep optical focusing in scattering media such as biological tissue, overcoming the diffusion limit of light. However, in practice, guide stars formed using contrast agents or ultrasonic modulation naturally occupy regions much larger than the optical resolution, thus limiting their effectiveness. We propose and experimentally demonstrate a time-reversal focusing mechanism in scattering media that achieves focusing to a single speckle grain without the need for point-like guide stars.

View Article and Find Full Text PDF

Pixel-responsive optimization beamforming method for ultrasound transcranial imaging.

Med Image Anal

August 2025

College of Biomedical Engineering, Fudan University, Shanghai, 200433, China; Department of Rehabilitation Medicine, Huashan Hospital, Fudan University, Shanghai, China; School of Electrical Engineering, Northwest Minzu University, Lanzhou, 730124, China. Electronic address:

The propagation of acoustic waves through bone remains a longstanding challenge in transcranial ultrasound imaging. As a highly scattering medium, the skull causes significant distortions in the ultrasonic wavefield, introducing complex aberrations that hinder precise image reconstruction. Conventional delay-and-sum (DAS) algorithms, which process pixels independently, fail to account for inter-pixel relationships, limiting their ability to correct such distortions.

View Article and Find Full Text PDF

This study aims to address the challenges posed by uneven energy amplitude and a low signal-to-noise ratio (SNR) in the total focus imaging of coarse-crystalline elastic anisotropic materials. A novel method for acoustic field correction vector-coherent total focus imaging, based on the materials' properties, is proposed. To demonstrate the effectiveness of this method, a test specimen, an austenitic stainless steel nozzle weld, was employed.

View Article and Find Full Text PDF

Non-invasive imaging of the brain vascular system is key for the understanding and monitoring of cerebral small vessel disease and neurological disorders. ultrasound localization microscopy (ULM) is emerging as a powerful modality for the cerebral angiographic and hemodynamic imaging up to the microscopic scale in preclinical and clinical settings. However, the skull bone induces aberrations during ultrasonic propagation leading to distortions and shadowed regions.

View Article and Find Full Text PDF