The leaf width of a multileaf collimator (MLC) determines the dose conformity to the target volume. The objective of this study was to investigate the feasibility of a two-dimensional dynamic MLC (2DDMLC) to improve the treatment plan quality with a fixed leaf width. The treatment head of the Clinac linear accelerator with the Millennium 120 MLC was modelled with the Geant4 (for GEometry ANd Tracking) tollkit using the Monte Carlo (MC) method. The 2DDMLC produces a beam aperture by moving the MLC bank vertically to the leaf movement. Thus, the effect of the 2DDMLC motion on beam divergence and beam fluence resolution was evaluated by comparing the dose distributions between the conventional MLC motion and the 2DDMLC. Finally, the 2DDMLC was employed for dynamic conformal arc therapy for 13 brain cancer patients. The dose-volumetric parameters, including the dose delivered to 98% of the target volume (D ), percent volume given 20% of the prescribed dose (V ), and conformity index (CI) were compared with those of the conventional MLC. For the 6 MV beam of the MC model, the depth dose and lateral dose distribution differed by less than 2% between the simulation and measurement. The 2DDMLC did not significantly influence beam divergence and sharpened the beam. In clinical use, the dose delivered to the target was almost identical between the 2DDMLC and conventional MLC (D = 29.74 Gy versus 29.71 Gy, p = 0.18). The CI was improved with the use of the 2DDMLC (CI = 1.49 versus 1.47, p = 0.14). Moreover, irradiation of normal tissue was reduced with the 2DDMLC compared with conventional MLC (V = 17.22% versus 17.45%, p < 0.001). The 2DDMLC improved the dose conformity to the target volume and reduced the irradiation of the normal tissue compared with the conventional MLC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/ab57c4 | DOI Listing |
PLoS One
September 2025
Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea.
Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Medical Physics Division, Department of Medical Innovation & Technology, CUHK Medical Centre, Hong Kong SAR, China.
Background: Patient-specific quality assurance (PSQA) is crucial in radiation therapy to ensure accurate and safe dose delivery. The Elekta Unity MR-Linac system, which combines MRI with a linear accelerator, presents unique challenges for conventional PSQA methods due to its adaptive capabilities and the presence of a magnetic field.
Purpose: This study introduced a novel PSQA method for the Elekta Unity MR-Linac system, utilizing treatment log files and fluence map verification to provide a more efficient alternative to traditional measurement-based techniques.
Discov Oncol
August 2025
Department of Computer Science, Bahria University Lahore Campus, Lahore, 54000, Pakistan.
Brain tumors have a big effect on a person's health by letting abnormal cells grow unchecked in the brain. This means that early and correct diagnosis is very important for effective treatment. Many of the current diagnostic methods are time-consuming, rely primarily on hand interpretation, and frequently yield unsatisfactory results.
View Article and Find Full Text PDFAppl Radiat Isot
August 2025
Department of Oncology, Shenzhen Hospital, Southern Medical University, Shenzhen, 518101, China. Electronic address:
Purpose: With the rapid development of computer technology, techniques with high modulation capabilities, such as Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT), have been widely applied in radiotherapy. As a result, it has become essential to perform Pre-treatment Quality Assurance (PQA) for each treatment plan to prevent radiation accidents. We aim to validate the novel uRT-linac 506c's EPID system as an alternative method for PQA by comparing the performance with IMatriXX.
View Article and Find Full Text PDFMed Phys
July 2025
Cedars-Sinai Medical Center, Los Angeles, California, USA.
Background: Conventional patient-specific quality assurance (PSQA) methods rely on time-consuming physical measurements. While previous studies have successfully employed machine learning (ML) models to predict gamma passing rates (GPRs), their clinical utility remains limited due to GPR's weak correlation with dose-volume histogram (DVH) parameters. Thus, developing a novel PSQA framework that is non-measured and DVH-based (NMDB) presents a promising alternative.
View Article and Find Full Text PDF