A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A volumetric modulated arc therapy-based dynamic conformal arc technique with limited monitor units (VMATliMU) to reduce multileaf collimator interplay effects: A computational phantom study for stage I non-small-cell lung cancer. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality. VMATliMU was implemented by applying monitor unit limitations during VMAT reoptimisation to minimise MLC encroachment into target volumes. Using mesh-type reference computational phantom CT images, treatment plans were generated for a simulated stage I lung cancer case prescribed to 45 Gy in three fractions. VMATliMU, conventional VMAT, VMAT with leaf speed limitations, dynamic conformal arc therapy, and constant dynamic conformal arc therapy were compared. Plans were optimised for multiple isodose line prescriptions (50%, 60%, 70%, 80%, and 90%) to investigate the impact of dose distribution. Evaluation parameters included MLC positional accuracy using area difference ratios, dosimetric indices, gradient metrics, and organ-at-risk doses. VMATliMU prevented MLC encroachment into the internal target volume across 60%-90% isodose lines, showing superior MLC accuracy compared with other methods. At the challenging 50% isodose line, VMATliMU had 4.5 times less intrusion than VMAT with leaf speed limits. VMAT plans had better dosimetric indices than dynamic conformal arc plans. VMATliMU reduced monitor units by 5.1%-19.2% across prescriptions. All plans met the clinical dose constraints, with the aortic arch below tolerance and acceptable lung doses. VMATliMU combines VMAT's dosimetric benefits with the dynamic conformal arcs's simplicity, minimising MLC encroachment while maintaining plan quality. Reduced monitor units lower low-dose exposure, treatment time, and interplay effects. VMATliMU is usable in existing planners with monitor unit limits, offering a practical solution for lung stereotactic body radiation therapy.

Download full-text PDF

Source
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0332190PLOS

Publication Analysis

Top Keywords

dynamic conformal
24
conformal arc
24
interplay effects
16
monitor units
12
lung cancer
12
arc therapy
12
monitor unit
12
mlc encroachment
12
vmatlimu
9
volumetric modulated
8

Similar Publications