Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: We study the density and excitatory response of neurites, and Schwann cells (SCs) in fresh and cryopreserved stromal lenticules derived from small incision lenticule extraction (SMILE).

Methods: Human stromal lenticules (n = 23) were immunostained for β III-tubulin and imaged using spinning disk confocal laser microscopy, followed by three-dimensional reconstruction, to reveal neurite distribution. The lenticule neurite density (LND) was assessed using a validated neurite tracing and length measurement method with NeuronJ. LND was compared among groups of different lenticule thickness (71-165 μm) obtained from -3 to >-6 diopters (D) corrections. SCs were identified by marker expression and the laser effect on SC-neurite interaction was examined under transmission electron microscopy (TEM). Fresh porcine SMILE-lenticules (n = 18) were used for LND comparison among storage conditions and functional excitatory calcium response assay.

Results: Using a validated neurite length measurement method, we found an inverse correlation of LND with lenticule thickness. Higher LND was found in thinner lenticules obtained from lower power of correction (r = -0.8925, P < 0.0001), whereas total lenticule neurite lengths did not alter significantly with regards to lenticule thickness. SCs were identified by GAP43 and p75NTR expression and were closely associated with lenticule neurites under TEM. In porcine lenticules, LND and excitatory calcium response were reduced after cold and cryogenic storage, when compared to fresh lenticules.

Conclusions: The stromal neurites showed variations in density related to SMILE lenticule thickness and cryopreservation. With the presence of SC support and excitatory response, these neurite residues could retain minimal functionality that might serve as a potential advantage in the event of lenticule implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.19-27566DOI Listing

Publication Analysis

Top Keywords

lenticule thickness
16
lenticule
10
small incision
8
incision lenticule
8
lenticule extraction
8
excitatory response
8
stromal lenticules
8
lenticule neurite
8
validated neurite
8
length measurement
8

Similar Publications

Differences in the Corneal Biomechanical Responses to LASIK and KLEx Based on Parametric Numerical Simulation.

J Refract Surg

September 2025

From National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.

Purpose: To use parametric numerical simulation to characterize and compare the differences in corneal biomechanical responses to laser in situ keratomileusis (LASIK) and keratorefractive lenticule extraction (KLEx) under various surgical settings.

Methods: The Finite Element Model was used in a parametric study to evaluate corneal biomechanical responses to LASIK and KLEx, considering variations in preoperative corneal thickness, corneal flap/cap thickness and diameter, refractive correction, and optical zone diameter. Surgery-induced stress, displacement, and interface contact pressure were compared between LASIK and KLEx using the Wilcoxon signed-rank test.

View Article and Find Full Text PDF

Comparison of corneal biomechanics in post-smile, post-LASEK, and normal eyes with Brillouin microscopy.

J Optom

August 2025

Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China; Key Laboratory of Myopia and Related Eye Diseases, NHC, Shanghai, China; Shanghai Research Center of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China; Shanghai Engineering Research

Purpose: To characterize corneal biomechanics in post-small-incision lenticule extraction (SMILE), post-laser-assisted subepithelial keratomileusis (LASEK), and normal eyes using Brillouin microscopy.

Methods: This study included myopic patients who underwent corneal refractive surgery (SMILE or LASEK) at least 1 month prior to ensure corneal stability. A total of 177 eyes (79 post-SMILE, 24 post-LASEK, and 74 untreated normal eyes) from 177 patients were evaluated using Pentacam HR and Brillouin microscopy for morphological and biomechanical assessment, respectively.

View Article and Find Full Text PDF

Purpose: Pupilloplasty techniques are delicate, especially in phakic patients where the risk of touching the lens with the needle during the procedure is high. We report the case of a phakic patient in whom we used an allogeneic Kerato-lenticule Extraction (KLEx) lenticule temporarily to protect the lens during the procedure.

Observation: This is a 43-year-old male patient with a significant post-traumatic temporal iris defect.

View Article and Find Full Text PDF

The present study aimed to investigate the feasibility and design of producing a parallel/concave lenticule using an excimer laser on a convex corneal matrix lenticule . Optical coherence tomography was used to measure the thickness of the corneal stromal lenticules. Lenticules were cut using an excimer laser.

View Article and Find Full Text PDF

Introduction And Importance: Band keratopathy (Band keratopathy, BK) is not a rare corneal disease. However, BK secondary to juvenile idiopathic arthritis-associated uveitis (Juvenile Idiopathic Arthritis-associated Uveitis, JIA-U) is not common. This case is to investigate the feasibility, safety, and efficacy of Phototherapeutic Keratectomy Combined (Phototherapeutic Keratectomy Combined, PTK) with Epikeratophakia (Epikeratophakia.

View Article and Find Full Text PDF