98%
921
2 minutes
20
Purpose: To assess the effect on reducing the out-of-plane artifacts from metal objects in breast tomosynthesis (BT) using a novel artifact-reducing reconstruction algorithm in specimen radiography.
Methods And Materials: The study was approved by the Regional Ethical Review Board. BT images of 18 partial- and whole mastectomy specimens from women with breast cancer were acquired before and after a needle was inserted close to the lesion. The images were reconstructed using both a standard reconstruction algorithm, and a novel algorithm; the latter uses pre-segmentation to remove highly attenuating artifact-inducing objects from projection images before reconstruction. Images were separately reconstructed with and without segmentation, and combined into an artifact-reduced reconstruction. Standard and artifact-reduced BT-algorithms were compared visually and quantitatively using clinical images of mastectomy specimens and a physical anthropomorphic phantom. Six readers independently assessed the visibility of the lesion with and without artifact-reduction in a side-by-side comparison. A quantitative analysis was performed, comparing the signal-difference to background ratio (SDBR) and artifact spread function (ASF) between the two reconstruction methods.
Results: The magnitude of out-of-plane artifacts was clearly reduced with the novel reconstruction compared to BT-images without artifact reduction. Lesion masking by artifacts was largely averted; tumour visibility was comparable to standard BT images without a needle. In 76 ± 8% (standard deviation) of cases overall, readers could confidently state needle location. The same figure was 94 ± 6% for whole mastectomy cases, compared to 62 ± 17% for partial mastectomies. With metal artifact reduction, SDBR increased by 97% in the phantom, and by 69% in the mastectomies. The artifact spread function was substantially narrower.
Conclusion: Artifact reduction in BT using a novel reconstruction method enables qualitatively and quantitatively improved clinical use of BT when metal artifacts can be a limiting factor such as in tomosynthesis-guided biopsy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejrad.2019.04.014 | DOI Listing |
Interv Neuroradiol
September 2025
Department of Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
PurposeTo evaluate the potential of Photon-Counting Detector CT Angiography (PCD-CTA) for the assessment of carotid and subclavian artery stents compared to digital subtraction angiography (DSA) and Duplex ultrasound (DUS).MethodsThis study is a single-center, retrospective analysis of consecutive patients treated with a stent for high grade stenosis of the extra-cranial carotid and the subclavian artery between April 2023 and May 2024. Polyenergetic images (PE), iodine and virtual monoenergetic images were performed at different keV levels (40 and 80) and with two body vascular reconstruction kernels (Bv56 and 72) with and without iterative metal artifact reduction.
View Article and Find Full Text PDFACS Omega
September 2025
Department of Anthropology, Texas A&M University, College Station, Texas United States.
Following their defeat in the Texas Revolution of 1836, the Mexican Army disabled and buried cannons used in the defense of the Alamo. Rediscovered in 1852, 13 of these cannons have since journeyed through private collections and public exhibits before arriving at the Alamo. Among them is a bronze 4-pounder cannon, thought to have seen action during the battle itself.
View Article and Find Full Text PDFSmall Methods
September 2025
School of Physics and Optoelectronics, South China University of Technology, Wushan Road 381, Guangzhou, 510640, China.
Magnetic-field enhancement of the oxygen evolution reaction (OER) represents a promising route toward more efficient alkaline water electrolyzers, yet its origin remains debated due to overlapping effects of mass transport and reaction kinetics. Here, we present a general experimental strategy that employs strong forced convection to suppress uncontrolled transport arising from natural diffusion and magnetohydrodynamic (MHD) flows. Using polycrystalline Au electrodes, we show that this approach resolves subtle OER variations under controlled flow and field conditions.
View Article and Find Full Text PDFNeuroscience
September 2025
College of Electrical and Control Engineering, Xi'an University of Science and Technology, Xi'an 710054, China; Xi'an Key Laboratory of Electrical Equipment Condition Monitoring and Power Supply Security., Xi'an 710054, China.
Motor imagery (MI) based brain-computer interfaces (BCI) decode neural activity to generate command outputs. However, the limited number of distinguishable commands in traditional MI-BCI systems restricts practical applications. To overcome this limitation, we propose a multi-character classification framework based on Electroencephalography (EEG) signals.
View Article and Find Full Text PDFPhys Med Biol
September 2025
Engineering Physics, Tsinghua University, Liuqing Building, Haidian District, Beijing, China, Beijing, Beijing, 100084, CHINA.
Objective Low-dose interior tomography integrates low-dose CT (LDCT) with region-of-interest (ROI) imaging which finds wide application in radiation dose reduction and high-resolution imaging. However, the combined effects of noise and data truncation pose great challenges for accurate tomographic reconstruction. This study aims to develop a novel reconstruction framework that achieves high-quality ROI reconstruction and efficient extension of recoverable region to provide innovative solutions to address coupled ill-posed problems.
View Article and Find Full Text PDF